MODEL

DESCRIPTION

Wide Range Area Monitor
Wide Range Area Monitor. Digital. Portable, Bench Top, Rack Mount, Wall Mount, or NEMA cabinet for hostile environments. Detects Gamma and Beta. Electronics: digital alarm ratemeter LAM-10D, built-in battery pack with charger, electrometer, and ion chamber.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NHL-4
Gamma Pocket Dosimeter

Dual Detector Wide Range Gamma Pocket Dosimeter. Digital and Analog. Portable. Detects Gammas, X-Rays. Alarming Gamma Rate and Dose Meter. Dual detector: Scintillator and Silicon Semiconductor. Dose and dose rate. Rugged, dust and water proof. function. Rechargeable batteries. EMF interference resistant. GPS search tool. Excellent for police, first responders, airport, and security personnel. Data download via reader.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NRF31
Gamma/X-Ray/Neutron

Gamma, X-Ray, Neutron Pocket Dosimeter. Digital. Portable. Dose and dose rate. Compact, lightweight, impact resistant with long battery life. EMF interference resistant. Data download via reader.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NRF34
Gamma/Beta/X-Ray Dosimeter

Gamma, Beta and X-Ray Pocket Dosimeter. Digital. Portable. Compact, lightweight, impact resistant with long battery life. Measures dose equivalent. EMF interference resistant. Data download via reader.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

P-8NEON
Quick Scan X-Ray

Quick Scan X-Ray Leak Detector. Portable. 8 GM detectors built into a 2-handled sweeper for large surfaces. Alarm lights for each detector. Locate leak then mark leak. Read leak emissions with X-Ray compliance meter TBM-IC-XRAY.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

This is a Photon Plasma Chamber® for an Area Monitor for a High Energy Accelerator. Digital. Two models: Installed, PLASMA-ACC and portable TBM-ACC-X. The ONLY accelerator plasma chamber® that will detect nanosecond pulsed X-Rays. It will accurately measure the integrated Total Dose from pulsed X-Ray machines over a wide range of pulse widths and repetition rates

  • PLASMA-ACC: Installed. AC power. Available in a multi-detector system. Data archive and retrieval. Local and remote read out and alarm. Computer interface.
  • TBM-ACC-X: Portable. Battery power. Single detector system. Local digital read out.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Universal Survey Meter. Portable. Digital or Analog. Use with Technical Associates GM, Proportional, Scintillation, Solid-State Probes. Alpha, Beta, Gamma, Neutron, X-Ray. Six decades. Four range survey meters with adjustable High Voltage, sensory input, and rugged construction. PUG-70; Built-In User Settable Alarm, PUG-7A; High Voltage System, PUG-7E; Zero Suppress Feature, PUG-7U; Full System; Electronics with PGS-3 Gamma Probe. Battery operated. Optional: AC. Local Read Out.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUG-7D Series
4 Range Survey

Four Range Survey Meter Universal Portable Monitor. Digital. Portable. Detects Alpha, Beta, Gamma, Neutron, X-ray. Works with all of Technical Associates GM, Proportional, Scintillation, and Solid-State Probes. Adjustable High Voltage, sensitive input, and rugged construction. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3D
Six Decade Meter

Six Decade Survey Meter. Digital. Portable. Works with all of Technical Associates GM, Proportional, and Scintillation probes including those for X-Ray and Positron. Local readout. Optional: alarm, computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3R
Radiographic Survey

Radiographic Survey Meter. Analog. Portable. Small, rugged, very light weight one hand operation three range ratemeter with built-in speaker. It has an anti-saturation circuit. Measures Gamma and X-Rays. Reads out directly in mR/hr. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SP
Dual Detector

Dual Detector Scintillation/Pancake TBM. Analog. Portable. Detects Alpha, Beta, Gamma, Iodine, Tc99m and X-ray. Lightweight system. Internal 2-inch pancake GM detector downward looking window at bottom of case with sliding shield protector. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SPE
1st Responder’s Emergency Kit

First Responder’s Radiation Detection Emergency Kit. Analog or Digital. Portable. Detects Alpha, Beta, Gamma, X-Ray and Neutron. Rugged, lightweight system. Internal 2-inch pancake GM detector downward looking window at bottom of case with sliding shield protector. Four external probes for detection of Alpha (PAS-8), low energy Gamma (PGS-3T), all Neutrons (PNS-20T), plus the Gamma Search Probe (PGS-3L). Kit comes in carrying case. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SP-ST
Surface Search Tool

Surface Monitor / Search Tool. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Internal 2-inch pancake GM detector downward looking window at bottom of case with sliding shield protector. External Model PGS-3 1'' x 1'' scintillation probe for use as a Gamma Search Tool and µ R Meter. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15
Frisker/3 Range Surface

Frisker 3 Range Surface Contamination Meter. Analog. Portable. Detects Alpha, Beta, Gamma and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonalert Local readout.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15D
Frisker/1 Range Surface

Frisker- 4 Decades, Single Range Surface Contamination Meter with No Range Switching. Digital. Portable. Detects Alpha, Beta, Gamma and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonalert. Local readout.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-LR
Low Gammas/Betas

All Gammas Including Low Energy Gammas, Betas (C-14) and X-Rays. Digital. Portable. Detects Alpha, Beta, Gamma. Portable. Local readout: 8 digit-rate, 8 digit integrate. Free Air ion chamber 5'' diax 7.5'' long. Internal volume 2 liters.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-PULSE-X
Nanosecond Pulsed X-Ray Detection

Nanosecond Pulsed X-Ray Detection. Digital. Portable. The only radiology imaging portable for nanosecond detection. Measures integrated Total Dose from pulsed x-ray machines over a wide range of pulse widths and repetition rates. Local readout. Meets 10CFR 34.25 - Federal Requirements for Radiation Survey Instruments. Click to See Reports. FAQ

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-MARK-V
Gamma, X-Ray Survey Meter

Gamma, X-Ray Survey Meter. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-MVR
Fast, Rugged Ion Chamber

Fast, Rugged Ion Chamber. Digital. Portable. Detects Beta, Gamma, X-Ray. Digital. Readout: 6 Digit-Rate, 8 Digit Integrate. Rate range is 0.1 mR/h to 50,000mR/h in a single range. Dose range is 0.01mR to 100R in a single range. Side view low energy (down to 20KeV) fluted chamber. (TBM-IC-LE). Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-XRAY
X-Ray Compliance Test Meter

X-Ray Compliance Test Meter. Digital. Portable. Detects low X-Ray energy scatter. Axially X-Rays or Below 15 Kev Gamma. Local Readout: 6 Digit-Rate, 8 Digit Integrate. Small, lightweight. Local readout.
Click For Portable Ion Chamber Comparison Chart

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .