MODEL

DESCRIPTION

CAM-33 Series
Air/Stack Monitors

Multi-Channel Air Monitor. Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases with a focus on Noble and Iodine gases. Note: TOTAL-6 focus is on Tritium and C-14. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Total Noble Gas, Noble Gas Curie MeV CAM-3XG. Local and remote alarming, readout, and monitoring of Data archive/retrieval. Computer interface.

Optional: Alpha, Tritium, and Carbon-14 detection are available. Local and remote alarming, readout and monitoring. A Commercial version is available for research labs, room air, and glove boxes. Click here for screenshots

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CAM-33-1P
Three Channel Air

Three Channel Air Monitor. Continuous Real-Time. Digital. Caster or Rack Mounted. Detects gross Beta-Gamma, Particulates, and Noble and Iodine gases. Flow rate 120 lpm standard. The user is settable. 1" lead shields. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. Click here for screenshots

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CARB-9-14
Carbon 14 Four Channel Air

CARBON-14 Air and Stack Monitor. Digital, bench top, the line operated. The CARB-F-14 detects the airborne concentration of C-14. Separately and simultaneously detects CO, Inorganic C-14, Net Organic C-14, and Particulates. Four channels. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FASTCAM-5
Plutonium Air Monitor

Quick Response Plutonium Air Monitor. Digital. Portable. Electronics; Portable or Bench Top. Sees Alphas and Betas in high or varying background situations. Two different detectors. Stand alone or networked with other detection locations. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9ABNI
PET/Iodine/99m

PET, Iodine, Tc-99m DTPA Air Monitor. DigitalPortable. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Application: Hospitals / Research, Power Plants, National Labs. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium Air and Stack Monitor. Digital. Installed. Continuous Real-Time. Ultra-sensitivity to low-level Tritium (at or Below Public Release Levels). Dose-rate and Dose. Can be located remotely. Archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MicroBAM-3ZL Series
3 Channel Air

High-Capacity Air Monitor. Digital. Portable (Hand Carry), Cart Mounted detachable. Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, and Noble Gas and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model 347. Digital. Highly sensitive tritium air monitor that includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model 357 Tritium in air monitor. Digital. Portable.General-Purpose. Dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarm. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PET-CAM-511
Positron Air System

Complete Positron Air Monitoring System for PET (Positron Emission Tomography) facilities. Digital. Installed. Continuous. 9 detector channels. 2 are monitors. Detects Positron, Particulate Beta/Gamma Iodine, Noble Gases. Local and remote readout, alarm, and monitoring. Data archive/retrieval. Computer interface. Easy integration into facility mainframe.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PTG-9-C-14
Carbon-14 Air/Stack

Carbon-14 Air/Stack Monitor. Digital. Electronics; Portable or Bench Top. Wide range. A sensitive, rugged, and portable instrument for detection and measurement of airborne C-14. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PTG-9-T
Tritium Air Monitor

Tritium Air Monitor. Digital. Electronics; Portable or Bench Top. Wide range. A sensitive, rugged, and portable instrument for detection and measurement of airborne Tritium. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PTG-9-RN
Radon Air/Stack

Radon Air Monitor. Digital. Portable or Bench Top. Highly sensitive and rugged. Dual balanced ion chambers. measure airborne radon as free Radon gas (with or without Radon Daughters user’s option) as low as 1pCi/l. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAAM-1-4HVM and SAAM
Six Weeks Unattended Operation

Moving Air Filter, Alpha Less Radon. Digital. Installed. Alpha, Beta/Gamma. Two models are available:

  • SAAM-1:2-channels, detects gross Alpha and Beta/Gamma (1) GM, (1) ,scintillation detector.
  • SAAM-4HVM: 4-channel, detects gross Alpha, Beta/Gamma, short and long-life particulates. (4) detectors: (1) solid state, (2) GM, (1) scintillation.

Optional: with SAAM-1 detection of Pu-239, U-238 and/or other nuclides. Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAAM-1HVM and SAAM-3
Six Weeks Unattended Operation

Moving Air Filter, Alpha Less Radon. Digital. Installed. Two models are available:

  • SAAM-1HVM: 2-channel, dual detectors (1) solid-state (1) scintillation. Simultaneous measurement of gross Alpha, Beta/Gamma particulates.
  • SAAM-3: Detects Alpha only. (1) solid-state detector Optional: Detection of Pu-239, and U-238, and/or other nuclides.

Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAAM-2HVM
Six Weeks Unattended Operation

Moving Air Filter 3 Channel Monitor, Alpha Less Radon. Digital. Installed.

  • SAAM-2VHMSimultaneous measurement of gross Alpha, Beta/Gamma particulates, Noble Gas and Iodine. (3) detectors (2) GM (1) scintillation.

Optional: Detection of Pu-239, and U-238, and/or other nuclides. Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

STG-4S/D and STG-5ALT
Tritium Air Monitor

Tritium Monitor Continuous Real-Time. Installed. Stack or Effluent Monitors. Public Release Level, Sensitive, Rugged. No range switching. Audio/visual alarm; Local and Remote, Readout and Monitoring. Data archive/retrieval. Computer Interface.

  • STG-4S/D Digital, 6 decades, auto ranging.
  • STG-5ATL Analog 4 decades, Log scale. Measures Tritium as HTO in presence of other radioactive gases.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TOTAL-6
Stack Monitors

Stack Monitor. Digital. Installed. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium, and C-14 with a focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Data archive/retrieval. Local and remote alarming and monitoring. A Commercial version is available for research labs, room air, glove boxes, and other applicable uses.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TRIMARAN-AIR and STACK
Stack Monitors

Ultra Low-Level Automated Tritium Air and Stack Monitor. Digital. Installed. Designed for near real-time ultra-low level Tritium detection in Nuclear Power Plants using sample enrichment and proportional counting. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .