Waste Sites

The EPA has tough regulations when it comes to disposing of radioactive material. Scrap metal sites are at risk for substantial fines and returned scrap if it is found to be radioactive. Waste material sites that take in radioactive waste material must adhere to strict rules of detection and ongoing monitoring. Technical Associates, a division of US Nuclear Corp, has developed a suite of instruments designed specifically for the harsh environment of scrap metal yards and sites taking in radioactive waste.

MODEL

DESCRIPTION

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drone Flight Platform
UAV Air Forensics

Typical Features: Weather-resistant heavy-lift commercial UAVs. Automatic return to home, autonomous waypoint capability, intelligent flight modes, commercial-grade carbon fiber frame, GPS position and hold, Flight telemetry overlay, stable in 20 mph (32 km/h) wind.

Optional: Sense and Avoid
Payload up to 11 pounds, 6 commercial grade heavy-lift motor. Flight times up to 70 minutes, dependent on payload weight, speed 35 mph, (56 km/h), FPV camera, and real-time video downlink. USA made.

Fly Detectors Together or Separately. Optional: Cameras: User Specific Note: UAV Platform is Selected to Meet User’s Mission Requirements

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Plume detector. UAV mounted DroneRAD System. Digital. Portable. Alpha, Beta, Gamma, C-14. Aerial radiation detector DroneRAD software, built-in air pump, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Air Monitor and Plume detection DroneRAD-P. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Search Tool fixed source-detector. UAV mounted DroneRAD System. Digital. Portable. Gamma, optional Neutron aerial radiation detector, DroneRAD software, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Downward-looking Gamma and optional Fast Neutron spotters for ground, building, vehicle, and facility air surveillance. DroneRAD-ST. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DroneCHEM-LMC-TA
Laser Methane Detection

UAV Mounted Laser Methane Detector. Digital. Portable. Optical laser detector. Distance up to 82 feet (25 meters). Detects a wide variety of airborne chemicals. Standard list available on Data Sheet. User-specific chemical detection is available. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

UAV mounted. Digital. Portable. Laser detects airborne methane. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

Two UAV mounted detectors: GPS Linked

1) DroneChem-Aero-MS
Digital, portable or installed, battery or AC power, handheld. Local readout. User settable alarm (high or low) Detects multiple gases, with interchangeable sensor heads. Use for locating and measurement of leaks. Data archive/retrieval. Optional remote sensor capability. Optional temp and HR sensor.

2) DroneRAD-LMC-TA.
Digital. Portable. Laser detects airborne methane. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

Together detect airborne methane and locate and measure leaks.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Beta / Gamma Particulate Monitor. Digital. Portable. T-1190 GM detector. Flow rate 70 lpm standard. The filter is under constant surveillance via a thin window GM pancake detector. (FM-9-BG-C) has a cyclone particle separator. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Grapple or Crane Mounted Gamma & Neutron Radiation Detector & System. Suitable for any grapple or crane. No moving parts, quick change between grapples or crane. Display in the Grapple Operator cab. Optional Wireless remote alarm and display to the base station.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LIM-21GFAT
1 Belt Laundry Monitor, extra sensitive, high speed. Uses eight gas flow detectors 6" x 16" and shift register and N of 8 electronics. Detects Beta-Gamma Radiation.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable Personnel, Vehicle, and Hallway/Doorway Monitors. Digital. Portable or Installed. Pass between dual scintillation detectors. Weather-proof. Continuous operation ‘set and forget’.

3 Mounting Models:

  • PPVM-TA Portable: Freestanding, Fences, Walls or Doorways.
  • PPVM-TB Higher sensitivity than the PPVM-TA.
  • PPVM-HM Designed for indoor use, hallways and doorways.
  • PPVM-TA-1 Single Detector Model.

Optional: Overhead detector. Underfoot detector. Neutron detector.
Optional: Local and remote alarm, readout and monitoring. Computer interface.
Optional: Wireless remote notification – phone, email, text, video recording.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gamma Silt & Particulate Raw Water Monitor

Raw Water Monitor Continuous Real-Time. Digital. Portable or Installed. Continuous. Detects Gamma. Single detector (RAWA-GP). Dual detector (RAWA-BGP) for Beta & Gamma. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Useful in complying with discharge requirements for waste-water. Modular system allows function changes or additions and rapid repair in the field.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Liquid Scintillation Counting System. Digital. Bench Top. Detects all Alpha/Beta Emitters and Low Energy Gamma Emitters–IncludingØTritium, Carbon-14, & Sulphur-35 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample (SSS-12P), 3 samples (SSS-22P), 3 samples with a Multichannel Analyzer (SSS-22-MCA), suitcase version of SSS-22P (SSS-22PAL), lab version of SSS-22P (SSS-22LAB). Local readout and alarm. Computer interface. Optional 6 sample adapter.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Alpha, Beta-Gamma, and X-Ray Surface Contamination Meter. Digital. Portable. Surface contamination monitor. Recommended by experts for fire department and First Responder use. Local readout.

Optional: computer interface.

Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15D

Frisker- 4 Decades, Single Range Surface Contamination Meter with No Range Switching. Digital. Portable. Detects Alpha, Beta, Gamma and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonalert. Local Readout.

Optional: computer interface.

Click For Gm Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installed Vehicle Monitors. Digital. Installed. Pass between dual scintillation detectors.

4 models:
- VMF-TA & VMF-TB each have 528”2 scintillation area.
- VMF-TB has higher sensitivity then VMF-TA.
- VMF-4X doubles the sensitivity area.
- VM-4XO has an overhead detector.

Local and remote alarm, readout and monitoring. Computer interface.
Optional: Neutron detector. Wireless remote notification – phone, email, text, video recording.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .