SURVEY, SURFACE, FRISKER, RATEMETERS, SCALERS, PORTABLES

D2O-STA and D2O-FTA
Deuterium Oxide

D2O-STA sampler detects deuterium oxide in water, liquid, or gas. Digital. Portable or Benchtop. No sample preparation is required. Infrared spectrometry. Attenuated total reflectance (ATR). The small size allows positioning inside the glove box or fume hood. Touch panel display. D2O-STA with TA-specific software. AC power with rechargeable battery backup. Quick-snap sampling module. 10-year laser warranty. Computer interface. Optional: Flow through feature – D2O-FTA

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FF-27
Tritium Surface

Tritium and C-14 Surface Contamination Meter. Digital. Portable Gas flow proportional detector. Use for flat surfaces. 100cm2 sensitive area. Use with PRS-7 Electronics. Local readout. Optional: USB. Optional: probe for hands, clothing, and equipment.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9-IXE
Iodine-125/Xenon-125 Ratemeter

Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Quick connect Xenon detector. Quick connect Iodine detector and filter cartridge. Local Readout. Data archive/retrieval. Computer interface. Real-time mass flow meter. Use for stack, hood, glove box or area air.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9-M2
Beta Particulate System

Beta Particulate Air Monitor System. Digital. Bench Top. 2 GM detector system. (1) Beta Particulates, (1) for Dynamic Background Subtract. Integrated exposure. Local or remote continuous real-time sampling. Quick change filter. Built-in data logger and computer interface. Electronic Mass Flowmeter. Expandable system with FM-9 series modules.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FRISKER GM 2
Portable Dual Sensor

Lightweight Digital Frisker. Dual GM Pancake Sensors in paddle form with handle. Battery operated. Gamma detection. Portable. Electronics – PRS-2. 2 Separate scale factors for Rate and Total. USB port.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HG-80-GPS
Mercury

 

Mercury Air Monitor with GPS. Digital. Portable or benchtop. Real-time mercury detection. Built-in air pump. No sample preparation is required. Spectrometry with background correction. Color touch-screen. Audio/visual alarm, user settable. Built-in rechargeable battery. Local readout.  Data archive and retrieval. Computer interface. Optional: Carrying case.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LAM-10-D Series
C-DC Ratemeter

AC-DC Ratemeter. Digital. Portable or wall mount. The LAM-10D ratemeters are rugged and easy to use for laboratory or field applications. Power: AC mains or rechargeable batteries. Works with all of Technical Associates GM, Proportional, Scintillation, and Solid-State probes. The LAM-10D-I has an internal energy compensated probe. The LAM-10D-IC is the ratemeter for use with Ion Chambers. Local Readout. Optional: USB.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NSN3
Neutron Survey

Neutron Survey Meter. Digital. Portable. Designed for Nuclear Reactors, Neutron Sources, and Generators, customs inspections, etc. Lightweight. Fast count and zero drift. Measures ambient dose equivalent and ambient dose rate equivalent of Neutrons. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRS-7 & PRS-7-DSC
Analyzing Ratemeter Scaler

Analyzing Ratemeter Scalers. Digital. Portable. The PRS-7 is a Single Channel Analyzer. Dual Channel Analyzer (PRS-7-DSC) with two independent detector inputs and coincidence circuit. Both models have integrated and ratemeter functions. Three presettable window positions. Local readout. Optional: USB Computer interface. Use with a wide variety of GM, Proportional, and Scintillation Probes.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRS-2 Series
Dual Readout Scaler

PRS-2 Series Automatic Scalers have simultaneous dual readouts. Digital. Portable. PRS-2S has no energy discrimination. PRS-2F has energy discrimination. Local readout. Optional: USB Computer interface. Use with a wide variety of detectors.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUG-7-D Series
Digital 4 Range Survey

Four Range Survey Meter Universal Portable Monitor. Digital. Portable. Detects Alpha, Beta, Gamma, Neutron, X-ray. Works with all of Technical Associates GM, Proportional, Scintillation, and Solid-State Probes. Adjustable High Voltage, sensitive input, and rugged construction. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUG-7N-D
Digital Neutron PUG

Digital Neutron PUG. Digital. Portable. Detects fast or slow Neutrons. It is lightweight and includes the electronics, moderator, and probe. Use with GM or Scintillator detectors. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sample Counting Systems. Digital. Portable.

  • STG-4: Beta-Gamma Counting Scintillation System.
  • STG-4TP: Low Energy Gamma Scintillation System with preamplifier
  • STG-4T: Low Energy Gamma Scintillation System.
  • STB-3: Beta Gamma GM System.
  • STAM-2: Alpha Scintillation System.
  • STAM-5N: Neutron

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Alpha Beta Sample Counting System. Digital. Portable or Benchtop. Count Alpha & Beta emissions from air filters with dual scintillation detectors. 2-inch sample cavity. No shielding STG-ABS-42P. 2-inch Lead shielded drawer STG-ABS-42SElectronics: PRS-2F Automatic Scaler. Simultaneous dual readouts. Digital. Portable. PRS-2F has energy discrimination. Local readout. Optional: USB Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Alpha Beta Sample Counting System. Digital. Portable or Benchtop. Count Alpha & Beta emissions from air filters with dual scintillation detectors. 4-inch sample cavity.  Electronics: PRS-2F Automatic Scaler. Simultaneous dual readouts. Digital. Portable. PRS-2F has energy discrimination. Local readout. Optional: USB Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

STB-TF-6
Tritium Wipe Test

Tritium Wipe Test Counter. Speedy Feret. Digital. Portable. Detects Tritium, Carbon-14, Sulfur-35, etc. Gas flow proportional detector. No shielding SF-TF-6. 1-inch lead shielding SF-TF-6 Pb. Electronics (PRS-7). Three single-channel analyzer windows. AC or rechargeable battery power. Local readout. RS-232 Computer interface. Optional: USB. Alarm relay.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, a mass flow controller, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3 Series
Surface Contamination

Surface Contamination Monitors. Analog. Portable. Detects Alpha, Beta-Gamma, and X-ray. Recommended by experts for the fire department and first responder use. Local readout.
Click For GM Pancake Tube Response Report. 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3D-PAS-9
6 Decade Meter

Six Decade Scaler/Ratemeter Survey Meter. Digital. Portable. PAS-9: Alpha Scintillation Probe. TBM-3D electronics works with all of Technical Associates GM, Proportional, and Scintillation probes including those for X-Ray and Positron. Local readout. Optional: alarm, computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3R
Radiographic Survey Meter

Radiographic Survey Meter. Analog. Portable. Small, rugged, very lightweight one-hand operation three-range ratemeter with built-in speaker. It has an anti-saturation circuit. Detects Gamma and X-Rays. Reads out directly in mR/hr. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3R-D
Radiographic Survey Meter

Radiographic Survey Meter. Digital. Portable. Small, rugged, very lightweight one-hand operation three-range ratemeter with built-in speaker. It has an anti-saturation circuit. Detects Gamma and X-Rays. Reads out directly in mR/hr. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3SR-D
Surface Contamination

TBM-3SR-D is a Surface Contamination Meter. Digital. Portable, Alpha, Beta-Gamma, X-Ray. Built-in 2" diameter pancake tube with sliding Beta shield and speaker. 0.01 to 100.00 mR/hr. Recommended by experts for the fire department and first responder use. Local readout. Optional: 2-way serial ports for computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6A
Wide Alpha/Beta/Gamma

Wide Range Alpha, Beta, Gamma Survey Meter.  Analog. Portable. 5 Ranges: 0-0.2, 2, 20, 200, 2000mR/h. Energy compensated. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6GN
Gamma Micro/Neutron Analyzer

Gamma Micro Meter plus Neutron Analyzer. Digital. Portable. Dual readout with Gamma in μ R/hr and Neutrons in cps. Designed specifically for use by inspectors and guards, police, and hazmat squad to give warning in case of illicit or accidental storage or transport of radioactive and fissile material. Optional: telescoping wand. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SP
Dual Detector

Dual Detector Scintillation/Pancake GM. Analog. Portable. Internal 2-inch pancake GM detector downward looking window at bottom of the case with sliding shield protector detects Alpha, Beta, Gamma, Iodine, Tc99m, and X-ray. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SPE
First Responder’s Kit

First Responder’s Radiation Detection Emergency Kit. Analog or Digital. Portable. Detects Alpha, Beta, Gamma, X-Ray, and Neutron. Rugged, lightweight system. Internal 2-inch pancake GM detector downward-looking window at bottom of case with sliding shield protector. Four external probes for detection of Alpha (PAS-8), low energy Gamma (PGS-3T), all Neutrons (PNS-20T), plus the Gamma Search Probe (PGS-3L). Local readout. Kit comes in carrying case.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SP-ST
Search Tool

Surface Monitor / Search Tool. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Internal 2-inch pancake GM T-1190 detector downward looking window at bottom of the case with sliding shield protector. External Model PGS-3 1'' x 1'' scintillation probe for use as a Gamma Search Tool and µ R Meter. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6U-SV
Gamma Micro-R-Meter

Gamma Micro-R-Meter. Analog. Portable. Internal scintillation detector. Engineering units are µSv/h. Optional: mR/h. External probe with BNC connector. Internal and external probe circuits are switch selectable and independently calibrated. Optional: the second probe may be any GM, scintillation, or gas flow. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15
3 Range Frisker

Frisker 3 Range Surface Contamination Meter. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonalert. Local Readout.
Click For GM Pancake Tube Response Report. 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15D
Single Range Frisker

Frisker- 4 Decades, Single Range Surface Contamination Meter with No Range Switching. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonaler. Local Readout.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-20S
Beta/Gamma Survey

Beta and Gamma Survey Meter. Analog. Portable. Small, lightweight three range Analog Survey / Ratemeter with built in GM tube and speaker. One hand operation. Local readout. Reads out in mSv/h (or mR/h).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-23 Series
3 Range Ratemeter

Three-range ratemeter. Analog. Portable. Reads out in cpm or mR/hr. Detects Alpha, Beta, and Gamma Radiation.

  • TBM-23-W has an extendable 33'' long wand with a recessed and protected GM detector on the end.
  • TBM-23-LB reads Low Background. Use for Column monitoring chromatogram plate monitoring: general purpose monitoring.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-28 Series
Floor Monitor

Floor Monitor. Digital. Portable. Detects Alpha, Beta, and Gamma. (4) models: (1) GM pancake detector, swivel head, with a 1.2-meter wand with separable, small, three-range ratemeter TBM-28 and TBM-28-15. (4) GM pancake detectors, swivel head, with a 1.2-meter wand with separable, small, three-range ratemeter TBM-28/4 and TBM-28/4-15. Additional short handles included TBM-28-15 and TBM-28/4-15. Local readout and alarm.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Floor Contamination Monitor. Same as the TBM-28 except with four GM tubes instead of one, for a larger area of detection. Instrument will see Alpha, Beta, and Gamma. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-55 Series
Beta/Gamma Telescopic

High Range Beta/Gamma Telescopic Probe. Digital. Portable. Mid-to-high-range Beta-Gamma radiation detection system. TBM-55HR-D-W wide Range. TBM-55HR-D-N narrow Range. Probe, extendable telescopic 6 oz. wand to 5 ½ feet. Optional: extendable want to 10 ½ feet, 24 oz. Electronics with ruggedized meter readout. System operated by a 9-volt battery. Lightweight, compact size permits easy transport and use. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-ACC-X
High Energy Accelerator
Plasma Chamber System

High Energy Accelerator Plasma Chamber® Area Monitor. Digital. Two models: Installed, PLASMA-ACC and portable TBM-ACC-X. The ONLY accelerator plasma chamber® that will detect nanosecond pulsed X-Rays. It will accurately measure the integrated Total Dose from pulsed X-Ray machines over a wide range of pulse widths and repetition rates

  • PLASMA-ACC: Installed. AC power. Available in a multi-detector system. Data archive and retrieval. Local and remote readout and alarm. Computer interface.
  • TBM-ACC-X: Portable. Battery power. Single detector system. Local digital readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-AJI
Integrated Ion Chamber

Integrating Ion Chamber. Digital. Portable. Free Air ion chamber 3.7'' dia x 6'' long. The internal volume is almost one liter. High sensitivity for Alphas and low energy Betas such as C-14. Also detects higher energy Betas and Gammas and X-rays down to 2 KeV. The TBM-IC-AJI ion chamber is lightweight and stable with essentially drift-free electrometer technology. Optional: RS232 Serial Port. Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-HLS
Wide Range Ion Chamber

Wide Range Ion Chamber. Digital. Portable. Alpha, Beta, Gamma, X-Ray.  Detects X-Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. Local readout. This very wide range conforms to  ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-LR
Low Range Gammas and Betas

Low Range Ion Chamber. Digital. Portable. Measures Alpha, Beta, Gamma, and X-RayAll Gammas Including Low Energy Gammas, Betas (C-14), and X-Rays. Detects X-Ray pulse down to 0.002 μR. Measures down to the background. Measures all Gammas including low-energy Gammas and X-Rays. Sees axially below 5 KeV Gamma or X-Rays. Wide range 0.1 mR/hr to1,000R/hr. Local readout: 8 digit-rate, 8-digit integration. Free Air ion chamber. Internal volume 2 liters. ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-PULSE-X
Nanosecond Pulsed X-Ray Detection

Nanosecond Pulsed X-Ray Detection. Digital. Portable. The ONLY radiology imaging portable for nanosecond detection. Measures integrated Total Dose from pulsed x-ray machines over a wide range of pulse widths and repetition rates. Local readout. MEETS 10CFR 34.25 - Federal Requirements for Radiation Survey Instruments. FAQ.
Click to See Reports.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-MARK-V
Gamma, X-Ray Survey Meter

Gamma, X-Ray Survey Meter. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-MVR and TBM-IC-LE
Fast, Rugged Ion Chamber

Fast, Rugged Ion Chamber. Digital. Portable. Detects Beta, Gamma, X-Ray. Digital. Readout: 6 Digit-Rate, 8 Digit Integrate. Rate range is 0.1 mR/h to 50,000mR/h in a single range. Dose range is 0.01mR to 100R in a single range. Side view low energy (down to 20KeV) fluted chamber. TBM-IC-LE Local readout.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-RN
Portable Fast Radon Detector

Portable Fast Radon Detector. Digital. Portable. Detects 10 picoCi/l in 5 seconds and detects public release level in less than 10 minutes. Small, lightweight. Drift-free electrometer technology. Measures ambient radon and no air pump is required. Local readout.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-XRAY
X-Ray Compliance Test Meter

X-Ray Compliance Test Meter.  Digital. Portable. Detects low x-ray energy scatter. Axially x-rays or below 15 KeV Gamma.  Local readout. 6 Digit-Rate, 8 Digit Integrate. Small. Lightweight.