MODEL

DESCRIPTION

SURVEY, SURFACE, FRISKER, RATEMETERS, SCALERS, PORTABLES

FF-27
Tritium Surface

Tritium and C-14 Surface Contamination Meter. Digital. Portable Gas flow proportional detector. Use for flat surfaces. 100cm2 sensitive area. Use with PRS-7 Electronics. Local readout. Optional: USB. Optional: probe for hands, clothing, and equipment.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9-IXE
Iodine-125/Xenon-125 Ratemeter

Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Quick connect Xenon detector. Quick connect Iodine detector and filter cartridge. Local Readout. Data archive/retrieval. Computer interface. Real-time mass flow meter. Use for stack, hood, glove box or area air.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9-M2
Beta Particulate System

Beta Particulate Air Monitor System. Digital. Bench Top. 2 GM detector system. (1) Beta Particulates, (1) for Dynamic Background Subtract. Integrated exposure. Local or remote continuous real-time sampling. Quick change filter. Built-in data logger and computer interface. Electronic Mass Flowmeter. Expandable system with FM-9 series modules.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FRISKER GM 2
Portable Dual Sensor

Lightweight Digital Frisker. Dual GM Pancake Sensors in paddle form with handle. Battery operated. Gamma detection. Portable. Electronics – PRS-2. 2 Separate scale factors for Rate and Total. USB port.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HG-80-GPS
Mercury

 

Mercury Air Monitor with GPS. Digital. Portable or benchtop. Real-time mercury detection. Built-in air pump. No sample preparation is required. Spectrometry with background correction. Color touch-screen. Audio/visual alarm, user settable. Built-in rechargeable battery. Local readout.  Data archive and retrieval. Computer interface. Optional: Carrying case.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LAM-10-D Series
C-DC Ratemeter

AC-DC Ratemeter. Digital. Portable or wall mount. The LAM-10D ratemeters are rugged and easy to use for laboratory or field applications. Power: AC mains or rechargeable batteries. Works with all of Technical Associates GM, Proportional, Scintillation, and Solid-State probes. The LAM-10D-I has an internal energy compensated probe. The LAM-10D-IC is the ratemeter for use with Ion Chambers. Local Readout. Optional: USB.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NSN3
Neutron Survey

Neutron Survey Meter. Digital. Portable. Designed for Nuclear Reactors, Neutron Sources, and Generators, customs inspections, etc. Lightweight. Fast count and zero drift. Measures ambient dose equivalent and ambient dose rate equivalent of Neutrons. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRS-7 & PRS-7-DSC
Analyzing Ratemeter Scaler

Analyzing Ratemeter Scalers. Digital. Portable. The PRS-7 is a Single Channel Analyzer. Dual Channel Analyzer (PRS-7-DSC) with two independent detector inputs and coincidence circuit. Both models have integrated and ratemeter functions. Three presettable window positions. Local readout. Optional: USB Computer interface. Use with a wide variety of GM, Proportional, and Scintillation Probes.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PRS-2 Series
Dual Readout Scaler

PRS-2 Series Automatic Scalers have simultaneous dual readouts. Digital. Portable. PRS-2S has no energy discrimination. PRS-2F has energy discrimination. Local readout. Optional: USB Computer interface. Use with a wide variety of detectors.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUG-7-D Series
Digital 4 Range Survey

Four Range Survey Meter Universal Portable Monitor. Digital. Portable. Detects Alpha, Beta, Gamma, Neutron, X-ray. Works with all of Technical Associates GM, Proportional, Scintillation, and Solid-State Probes. Adjustable High Voltage, sensitive input, and rugged construction. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PUG-7N-D
Digital Neutron PUG

Digital Neutron PUG. Digital. Portable. Detects fast or slow Neutrons. It is lightweight and includes the electronics, moderator, and probe. Use with GM or Scintillator detectors. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

STB-TF-6
Tritium Wipe Test

Tritium Wipe Test Counter. Digital. Portable. Detects Tritium, Carbon-14, Sulfur-35, etc. Gas flow proportional detector. Electronics (PRS-7). Three single channel analyzer windows. AC or rechargeable battery power. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, a mass flow controller, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3 Series
Surface Contamination

Surface Contamination Monitors. Analog. Portable. Detects Alpha, Beta-Gamma, and X-ray. Recommended by experts for the fire department and first responder use. Local readout.
Click For GM Pancake Tube Response Report. 

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3D-PAS-9
6 Decade Meter

Six Decade Survey Meter. Digital. Portable. Works with all of Technical Associates GM, Proportional, and Scintillation probes including those for X-Ray and Positron. Local readout. Optional: alarm, computer interface.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3R
Radiographic Survey Meter

Radiographic Survey Meter. Analog. Portable. Small, rugged, very lightweight one-hand operation three-range ratemeter with built-in speaker. It has an anti-saturation circuit. Detects Gamma and X-Rays. Reads out directly in mR/hr. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3R-D
Radiographic Survey Meter

Radiographic Survey Meter. Digital. Portable. Small, rugged, very lightweight one-hand operation three-range ratemeter with built-in speaker. It has an anti-saturation circuit. Detects Gamma and X-Rays. Reads out directly in mR/hr. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3SR-D and
TBM-3SR-DN
Alpha/Beta-Gamma/X-Ray,
Neutron

Alpha, Beta-Gamma, X-Ray (TBM-3SR-D) Alpha, Beta-Gamma, X-Ray, and Neutron (TBM-3SR-DN) Surface Contamination Meter. Digital. Recommended by experts for the fire department and first responder use. Local readout. Optional: 2-way serial ports for computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6A
Wide Alpha/Beta/Gamma

Wide Range Alpha, Beta, Gamma Survey Meter.  Analog. Portable. 5 Ranges: 0-0.2, 2, 20, 200, 2000mR/h. Energy compensated. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6GN
Gamma Micro/Neutron Analyzer

Gamma Micro Meter plus Neutron Analyzer. Digital. Portable. Dual readout with Gamma in μ R/hr and Neutrons in cps. Designed specifically for use by inspectors and guards, police, and hazmat squad to give warning in case of illicit or accidental storage or transport of radioactive and fissile material. Optional: telescoping wand. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SP
Dual Detector

Dual Detector Scintillation/Pancake TBM. Analog. Portable. Detects Alpha, Beta, Gamma, Iodine, Tc99m, and X-ray. Lightweight system. Internal 2-inch pancake GM detector downward-looking window at bottom of case with sliding shield protector. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SPE
1st Responder’s Emergency Kit

First Responder’s Radiation Detection Emergency Kit. Analog or Digital. Portable. Detects Alpha, Beta, Gamma, X-Ray, and Neutron. Rugged, lightweight system. Internal 2-inch pancake GM detector downward-looking window at bottom of case with sliding shield protector. Four external probes for detection of Alpha (PAS-8), low energy Gamma (PGS-3T), all Neutrons (PNS-20T), plus the Gamma Search Probe (PGS-3L). Local readout. Kit comes in carrying case.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6SP-ST
Surface Search Tool

Surface Monitor / Search Tool. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Internal 2-inch pancake GM detector downward-looking window at bottom of the case with sliding shield protector. External Model PGS-3 1'' x 1'' scintillation probe for use as a Gamma Search Tool and µ R Meter. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-6U-SV
Gamma Micro-R-Meter

Gamma Micro-R-Meter. Analog. Portable. Internal scintillation detector. Engineering units are µSv/h. Optional: mR/h. External probe with BNC connector. Internal and external probe circuits are switch selectable and independently calibrated. Optional: the second probe may be any GM, scintillation, or gas flow. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15
Frisker/3 Range Surface

Frisker 3 Range Surface Contamination Meter. Analog. Portable. Detects Alpha, Beta, Gamma and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonalert. Local Readout.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15D
Frisker/1 Range Surface

Frisker- 4 Decades, Single Range Surface Contamination Meter with No Range Switching. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonaler. Local Readout.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-20S
Beta/Gamma Survey

Beta and Gamma Survey Meter. Analog. Portable. Small, lightweight three range Analog Survey / Ratemeter with built in GM tube and speaker. One hand operation. Local readout. Reads out in mSv/h (or mR/h).

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Outreach TBM. A 33'' long wand with separable small three range ratemeter. Reads out in counts per minute (and mR/hr). Thin window one inch diameter GM detector at end of “long arm” is recessed and protected by sturdy aluminum grill. Instrument will see Alpha, Beta and Gamma Radiation. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-28 and TBM-28-15 Floor Contamination Monitor. A 1.2 meter wand with separable, small, three-range ratemeter. Reads out in counts per minute. Thin pancake wide face GM detector at end of long arm is recessed and protected by sturdy aluminum grill. Instrument will see Alpha, Beta, and Gamma. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Floor Contamination Monitor. Same as the TBM-28 except with four GM tubes instead of one, for a larger area of detection. Instrument will see Alpha, Beta, and Gamma. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-55 Series
Beta/Gamma Telescopic

High Range Beta/Gamma Telescopic Probe. Digital. Portable. Mid-to-high-range Beta-Gamma radiation detection system. TBM-55HR-D-W wide Range. TBM-55HR-D-N narrow Range. Probe, extendable telescopic 6 oz. wand to 5 ½ feet. Optional: extendable want to 10 ½ feet, 24 oz. Electronics with ruggedized meter readout. System operated by a 9-volt battery. Lightweight, compact size permits easy transport and use. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-ACC-X
Accelerator Monitor

Portable Plasma Chamber® for a High Energy Accelerator. Digital. Portable. The PLASMA-ACC is the ONLY accelerator plasma chamber® that will detect nanosecond pulsed X-Rays over a wide range of pulse widths and repetition rates. Installed model: Plasma-ACC. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-AJI
Integrated Ion Chamber

Integrated Ion Chamber. Digital. Portable. Detects X-Ray Pulse down to 0.2μR and 0.0001 mR to 10 R Total Dose. Local readout.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-HLS
Wide Range Monitor

Wide Range Ion Chamber. Digital. Portable. Alpha, Beta, Gamma, X-Ray. Detects X- Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. Local readout. ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-LR
Low Energy Gammas/Betas

TBM-IC-LR Portable Ion Chamber. All Gammas Including Low Energy Gammas, Betas (C-14) and X-Rays. Digital. Portable. Detects Alpha, Beta, Gamma. Local readout: 8 digit-rate, 8 digit integrate. Free Air ion chamber 5'' dia x 7.5'' long. Internal volume 2 liters.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-PULSE-X
Nanosecond Pulsed X-Ray Detection

Nanosecond Pulsed X-Ray Detection. Digital. Portable. The only radiology imaging portable for nanosecond detection. Measures integrated Total Dose from pulsed x-ray machines over a wide range of pulse widths and repetition rates. Local readout. Meets 10CFR 34.25 - Federal Requirements For Radiation Survey Instruments. Click to See Reports. FAQ

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-MARK-V
Gamma, X-Ray Survey Meter

Gamma, X-Ray Survey Meter. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-MVR
Fast, Rugged Ion Chamber

Fast, Rugged Ion Chamber. Digital. Portable. Detects Beta, Gamma, X-Ray. Digital. Readout: 6 Digit-Rate, 8 Digit Integrate. Rate range is 0.1 mR/h to 50,000mR/h in a single range. Dose range is 0.01mR to 100R in a single range. Side view low energy (down to 20KeV) fluted chamber. (TBM-IC-LE). Local readout.

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-RN
Portable Fast Radon Detector

Portable Fast Radon Detector. Digital. Portable. Detects 10 picoCi/l in 5 seconds and detects public release level in less than 10 minutes. Small, lightweight. Drift-free electrometer technology. Measures ambient radon and no air pump is required. Local readout.
Click for Portable Radon Comparison Chart

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-XRAY
X-Ray Compliance Test Meter

X-Ray Compliance Test Meter. Digital. Portable. Detects low X-Ray energy scatter. Axially X-Rays or Below 15 Kev Gamma. Local readout. 6 Digit-Rate, 8 Digit Integrate. Small, lightweight.
Click For Portable Ion Chamber Comparison Chart

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .