Tritium: Water Monitors

MODEL

DESCRIPTION

FPT-H3 Series
Fuel Pool Tool

Fuel Pool Tool. Digital. Installed. Detects Tritium in NPP pool water, pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only (FPT-H3). (1) Tritium plus Alpha-Beta-Gamma Detectors (FPT-H3-ABG). Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium in Water Monitor. Digital. Benchtop. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ultra-Sensitive Tritium in Water Monitor. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water  Fully automated, real-time, continuous. Integrated computer with custom software and large LCD display. Monitors water below EPA drinking water standard of 20,000 pCi/l.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Molten Salt Thorium Reactor Water MonitorReal-time Continuous. Digital. Installed. Detects Thorium, Tritium, Alpha, Beta and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Monitor Continuous Real-Time. Digital. Portable or Installed. Continuous. Detects Alpha, Beta, and Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Water Monitor. Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.

Optional: Tritium, C-14, Radon detection.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

Optional: Ozone System.
Optional: Tritium detection.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital, Bench Top or Rack mounted. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Meets EPA drinking water levels.

  • Monitor Leaks in Candu Type Reactors
  • Monitor Tritium Contamination in Ground Water.
  • Monitor Laboratory or Plant Liquid Waste Stream.

Strategy for Measurement of Tritium in Water / Oil Mixture.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drinking/Waste Water Monitor. Continuous Real-Time. In-Line or transportable (Rack Mounted or Wheeled Base). Detects Gamma. Monitor ground, surface water, industrial liquid-waste-stream. MCA isotope Identifier – Detector Type:   NAI (TL) OR HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector.

Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

Optional: Detectors: Alpha, Beta, Tritium, Radon. Optional: Submersible Gamma probe

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drinking-Water Monitor Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
Optional: Ozone System. Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water). FAQ

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. SSS-22-LAB with stainless steel case, lab version of SSS-22P. Local readout and alarm. Computer interface. Optional: 6 sample adapters.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Optional: 6 sample adapters. Six models:

  • 1 sample SSS-12P
  • 3 samples of SSS-22P,
  • 3 samples with a Multichannel Analyzer SSS-22-MCA,
  • All-in-one suitcase version: 3 sample systems and electronics SSS-22PAL
  • SSS-22PAL-ID comes with MCA,
  • SSS-22-LR (Low Range Tritium).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Liquid Scintillation Counting System. Digital. Bench Top. The suitcase version of SSS-22P (SSS-22PAL or SSS-22PAL-ID with MCA), Quantitatively measures Carbon-14 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Multichannel Analyzer SSS-22-MCA, lab version of SSS-22P SSS-22LAB, SSS-22-LR (Low Range Tritium). Local readout and alarm. Computer interface. Optional 6 sample adapter.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MIL-Water Safety Test Liquid Scintillation Counting System. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Portable electronics (SSS-22LR). Installed electronics (SSS-22LRX). Local readout and alarm. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Down Hole Tritium in Water Monitor. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline. Five models:

  • SSS-33-DHC and SSS-33-DHC-4 each will deploy to 160 feet.
  • SSS-33-DHC utilizes a two-inch diameter well hole.
  • SSS-33-DHC- 4 utilizes a four-inch diameter well hole.
  • SSS-33-DH-XT utilizes a two-inch diameter well hole and will deploy 5,000 feet.
  • SSS-33-DHC-WH and SSS-33-DHC-4-WH utilize the WELL-HEAD (WH) SERIES procedure.

The WELL-HEAD (WH) SERIES procedure has the same function as the other models, with significantly higher sensitivity and reduced maintenance by the simple expedient of placing only the pump down the hole and bringing the detection cell, filtration, and amplifiers up to the surface where they can sit alongside the readout and data transmission package which was already on the surface at the WELL-HEAD. There are thousands of boreholes in the United States which could be or should be monitored for Tritium.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Radon and Tritium Deionizer and Filter. Is a two-stage deionizer producing water equivalent to -distilled water. SSS-33M8-D are the deionizer cartridges. SSS-33M8-F is the Filter.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ultra Low-Level Tritium Water Continuous Real-Time Monitor. Digital. Installed. Designed for near real-time ultra-low-level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Trimaran-H2O-ES has enhanced sensitivity in a shorter time period. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .