Medical: Facility Air / Water Portal

Model

Product Image

Description

Department

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9W-V

Radiation Control Monitor. Digital. Bench Top or Installed.

  • Exit/Doorway Monitor
  • Package/Mail Monitor
  • Vehicle Monitor
  • Laundry Monitor

Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.

▪ Imaging
▪ Diagnostics
▪ Facility
▪ Research/Lab
▪ Radiopharmacy

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LAM-10D Series

LAM-10D Series

Radiation Control Monitor- EXIT/DOORWAY MONITOR, PACKAGE/MAIL MONITOR, VEHICLE MONITOR, LAUNDRY MONITOR
Digital. Detects Beta/Gamma. Mount above sorting table, conveyor belt, or doorway.

(2) models:
(1) 1” x 1” scintillation crystal (PGS-3).
(1) 2” x 2” scintillation crystal (PGS-3L).

Electronics: LAM-10. Audiovisual alarm. Optional: Wireless remote notification – phone, email, text, video recording.

Installed

Facility

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water monitor for Alpha isotopes: Most Alphas including U-238, Po-210, and Radon. Digital, Benchtop, or installed. Continuous Real-Time water monitor. Monitor for contamination of in-ground or surface water. Monitor liquid waste stream from hospitals, laboratories or plants, mining/oil/gas extraction, and Nuclear Power plants. Data archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water monitor for Beta isotopes: I-131, Sr-90/Y-90, Sr-89, Cs-137, Cs-134 etc. Digital, Benchtop, or installed. Continuous Real-Time Monitor drinking water against any and all Beta Emitter Contaminants except H-3, C-14, S-35 Monitor for contamination in-ground or surface water Monitor liquid waste stream from laboratory or plant.

Facility

▪ Water Inlet Pipes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Test/Treat System. Digital. Portable or Installed. Alpha, Beta, Gamma detection.  BioSensor for Oxidation Reduction Potential (ORP) and Total Organic Carbon (TOC). Test & Treatment for radioactive and biological contamination.

Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring & treatment of drinking water 24/7. Facilities with multiple water inlets may wish to install multiple NEX-ABG-9TTs. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.

Facility

▪ Water Inlet Pipes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Monitor Continuous Real-Time. Digital. Portable or Installed. Detects Alpha, Beta, Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface. (3) Models:

  • (1) Portable with User’s electronics
  • (1) Installed with embedded processor
  • (1) Portable with embedded processor

Facility

▪ Water Inlet Pipes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PPVM Series
Portal Monitors

PPVM-TA

Portable Personnel, Vehicle, and Hallway/Doorway Monitors. Digital. Portable or Installed. Pass between dual scintillation detectors. Weather-proof. Continuous operation ‘set and forget’.

3 Mounting Models:

  • PPVM-TA Portable: Freestanding, Fences, Walls, or Doorways.
  • PPVM-TB Higher sensitivity than the PPVM-TA.
  • PPVM-HM Designed for indoor use, hallways, and doorways.
  • PPVM-TA-1 Single Detector Model.

Optional: Overhead detector. Underfoot detector. Neutron detector.
Optional: Local and remote alarm, readout, and monitoring. Computer interface.
Optional: Wireless remote notification – phone, email, text, video recording.

Facility
▪ Entrance/Exit
▪ Hallways
▪ Laundry
▪ Trash Rooms

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

OXY-IS-D AIR - Oxygen measurement for ambient oxygen in the air. Wall mount. Diffusion style. No pump. Local readout or Computer interface.

OXY-IS-DF AIR - Oxygen measurement for process oxygen. Wall mount. or benchtop. Flow-through style. Quiet Air pump, 30 lpm.

Both OXY-IS-D and OXY-IS-DF - Dual scale 0-25%; 0-50%. Sensitivity 0.5% O2 in the air by volume. Local readout or Computer interface.

OXY-IS-DSUB WATER – Portable. Digital. Dissolved oxygen. Non-fouling cell diffusion style submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.

OXY-IS-DFW WATER - Dissolved oxygen. Non-fouling cell flows through submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-Mark–V

TBM-IC-Pulse-X

Gamma, X-Ray Survey Meter. Digital. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally, referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.

Portable

 

▪ Imaging Diagnostic
▪ Treatment
▪ Radiosurgery

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3SR-D

TBM-3SR-D

Alpha, Beta-Gamma, and X-Ray Surface Contamination Meter. Digital. Surface contamination monitor. Recommended by experts for fire department and First Responder use. Local readout. Click For GM Pancake Tube Response Report.

Portable

▪ RSO
▪ Full Facility
▪ Trash
▪ Imaging Diagnostic
▪ PET
▪ Nuclear Medicine
▪ Treatment
▪ Blood Lab
▪ Package

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

UNITECT-H2O

UNITECT

All-in-One, Continuous, Real-Time, Automatic, In-Line Water Monitor. Digital, Installed.

COMBINES MULTIPLE DETECTION GOALS INTO ONE MONITOR. Biological Detection (18): Measures with (4) or more different biosensors

CHEMICAL DETECTION (52): 7 or more major chemical tests provided or tailored to need including but not limited to: Turbidity, pH, Nitrates, Chloride.

TRACE & HEAVY METALS (17): Including but not limited to: Lead, Arsenic, Cadmium.

RADIATION DETECTION (5): Alpha, Beta, Gamma - OPTIONAL: Tritium, Radon.

SPECIFIC DETECTION, ANALYSIS, MEASUREMENT: Provides a critical guide for finding and correcting the upstream physical sources of contamination.

Data Archive / Retrieval; SCADA Compatible. Multi-Channel Analyzer and Library with 1024+ Channels. Local & Remote Display, Control, & Communications. No Reagents Required Except for Trace Metals.

Full Facility - Water

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .