MODEL
DESCRIPTION
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air/Stack Monitors
Multi-Channel Air Continuous Real-Time Monitor. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases with a focus on Noble ad Iodine gases. Note: TOTAL-6 focus is on Tritium and C-14. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Total Noble Gas, Noble Gas Curie MeV CAM-3XG. Local and remote alarming, readout, and monitoring of data archive/retrieval. Computer interface.
Optional: Alpha, Tritium, and Carbon-14 detection are available. Local and remote alarming, readout and monitoring. A Commercial version is available for research labs, room air, and glove boxes. Click here for screenshots
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAM-33-1P
Three Channel Air
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARBON-14 and Iodine Air and Stack Monitors. Digital. Installed. Electronics; Bench Top. Constant check with real-time alarm. Integrated exposure values. (3) models. Flow rate 50 lpm standard. Electronic mass flowmeter. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PET, Iodine, or Tc-99M DTPA
PET, Iodine, Tc-99m DTPA Air Monitor. Digital. Portable. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Application: Hospitals / Research, Power Plants, National Labs. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beta / Gamma Particulate Monitor. Digital. Portable. T-1190 GM detector. Flow rate 70 lpm standard. The filter is under constant surveillance via a thin window GM pancake detector. FM-9-BG-C has a cyclone particle separator. Data archive/retrieval. Computer interface. Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-IXE
Iodine-125/Xenon-125 Ratemeter
Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Local Readout. Data archive/retrieval. Computer interface. Real-time mass flow meter. Use for the stack, hood, glove box, or area air.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Xenon-133 Monitor
Xenon-133 Gas Monitor. Digital. Installed. Continuous. Flow rate 10 lpm standard. Local readout. Pre filter removes particulates. Local Readout. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MABC
Multiuse Radiation/Chemical
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MCA
PET/Iodine/Tc-99m
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MCA-2
Iodine-125/Gas/Particulate
Iodine-125 Air Gas and Particulate Air Monitor. Digital. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Computer interface. Flow rate 70 lpm standard. Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9NGAS
Noble Gases, Argon, Xenon, Krypton
Noble Gas, Argon, Xenon, Krypton Monitor, or Leak Detector. Real-time, continuous, digital display. Five models to choose from including the cart-mounted FM-9XE-NGL Leak Detector and the 10 scintillation detector model FM-9NGAS-10S. Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FR-PIB Series
Iodine Total Air Activity
Iodine Monitor Total Airborne Activity. Digital. Portable. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user-settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector. Line operated. Local readout. Data archive/retrieval. Computer interface.
FR-PII-Pb uses a ½" lead shield. Use as industrial workplace and hospital breathing air measurement system, and to monitor fume hoods and stack effluent down to EPA levels.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable 3 Channel Air
High-Capacity Air Monitor. Digital. Portable-Hand Carry, Cart Mounted, detachable. Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, and Noble Gas and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface. Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Positron Air System
Complete Positron Air Monitoring System for PET (Positron Emission Tomography) facilities. Digital. Installed. Continuous. 9 detector channels. 2 are monitors. Detects Positron, Particulate Beta/Gamma Iodine, Noble Gases. Local and remote readout, alarm, and monitoring. Data archive/retrieval. Computer interface. Easy integration into facility mainframe.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAAM-2VHM
Moving Air Filter
Moving Air Filter 3 Channel Monitor. Digital. Installed. Detects gross Alpha, Beta/Gamma particulates, Noble Gas and Iodine. (3) detectors (2) GM (1) scintillation. Optional: detection of Pu-239, and U-238 and/or other nuclides. Unattended operation up to 6 weeks. Counts separately and simultaneously. High capacity air pump; flow rate 4cfm standard to Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SP
Dual Detector
Dual Detector Scintillation/Pancake TBM. Analog. Portable. Detects Alpha, Beta, Gamma, Iodine, Tc99m and X-ray. Lightweight system. Internal 2-inch pancake GM detector downward-looking window at bottom of the case with sliding shield protector. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SPE
First Responder Kit
Description Coming Soon
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TOTAL-6
Nuclear Power Stack/Effluent
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .