Medical

Hospitals | Medical Schools | Biotechnology | Pharmaceutical Industry

Model

Description

Digital. Portable. Installed.
Bench Top or Cart Mount.

Quick Response Plutonium Air Monitor. Sees Alphas and Betas in high or varying background situations. Two different detectors. Stand-alone or networked with other detection locations. Local and remote alarming, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable. Installed.
Bench Top or Cart Mount.

Food and Cosmetic Monitor. Measure radioactive contamination in all types of food, cosmetics, or other bulk samples. One-liter capacity scintillation well detector. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable. Bench Top or Cart Mount.

PET, Iodine, Tc-99m DTPA Air Monitor. Digital Electronics. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Local and remote alarming, readout, and monitoring. Data archive/retrieval. Computer interface. Optional: MCA.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Iodine, Gas, and Particulate Monitor. Continuous. Electronics; Transportable or Mounted. Detects Gas and Particulates. High Sensitivity. Constant Check with Alarm. Data archive/retrieval. Computer interface. Integrated Exposure. Click For GM Pancake Tube Response Report. 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable. Installed.
Bench Top or Cart Mount.

Iodine-125 and Xenon-125 Ratemeter. Dual Ratemeter. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Local Readout. Data archive/retrieval. Computer interface. Real-time mass flow meter. Use for the stack, hood, glove box, or area air.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Xenon-133 Gas Monitor. Continuous. Flow rate 10 lpm standard. Local readout. Data archive/retrieval. Computer interface. Pre-filter removes particulates.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top.

PET, Iodine, or Tc-99m DTPA Air Monitor. Multi-Channel Analyzer (MCA). Continuous. Monitor air room or stack effluent. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top or Cart Mounted.

Iodine-125 Air Gas and Particulate Air Monitor. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed, Cart Mounted. Benchtop.

Noble Gas, Argon, Xenon, Krypton Monitor, or Leak Detector. Real-time, continuous. Five models to choose from include the cart-mounted FM-9XE-NGL Leak Detector and the 10 scintillation detector model FM-9NGAS-10S. Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top or Installed.

Wide Range Area Monitor. Detects Beta, Gamma, and X-Ray. Optional Neutron. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Use with wide range of TA detector types. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Accommodates over 50 types of detectors.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top or Installed.

Radiation Control Monitor. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Accommodates over 50 types of detectors.

  • Exit/Doorway Monitor
  • Package/Mail Monitor
  • Vehicle Monitor
  • Laundry Monitor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable. Digital.

Iodine Monitor Total Airborne Activity. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector. Line operated. Local readout. Data archive/retrieval. Computer interface.

FR-PII-Pb uses a ½" lead shield. Use as an industrial workplace and hospital breathing air measurement system, and monitor fume hoods and stack effluent down to EPA levels.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable. Digital.

Chromatogram Scanning Counter. AC. The HY-1 is a Medical Isotope System. It is an automatic scanner for TLCs, gels, paper chromatograms, and electrophoreses, to allow immediate visualization and estimation of isotopic content. Includes MCA. Onboard computer and Computer interface for data download.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Benchtop. Digital.

Chromatogram Scanning Counter. AC. The HY-1 is a Medical Isotope System. It is an automatic scanner for TLCs, gels, paper chromatograms, and electrophoreses, to allow immediate visualization and estimation of isotopic content. Accepts 3 detector types: GM, Gas Flow, and Scintillation. Scans 6 traces simultaneously. A moving 10" x 20" table carries two 20cm x 20 cm TLCs or other samples in controlled steps under a bridge, examines samples' traces, and transfers information to a printer or strip chart recorder. Detectors are interchangeable.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable. Analog.

AC-DC Radiation Monitor. The LAM ratemeters are rugged and easy to use for laboratory or field applications. AC or DC power. LAM-10 Electronics work with all of the Technical AssociatesGM, Proportional, Scintillation, and Solid State probes. Local Readout, Optional: USB.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

AC-DC Radiation Monitor. The LAM ratemeters are rugged and easy to use for laboratory or field applications. Operated by AC mains or by rechargeable batteries. Works with all of the Technical Associates GM, Proportional, Scintillation, and Solid State probes. The LAM-10D-I has an internal energy-compensated probe.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LEM-6G

Digital. Portable.

Drain Pipe Monitor. For liquid effluent. Gross Beta-Gamma. Complete system: rugged submersible probe and electronics.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Laundry Monitor. Detects Beta. Dual fast flow sorting (clean vs contaminated) conveyor belts. (4) 6" x 6" Scintillation detectors mounted in a conveyor belt rack. Electronics: Wall or Rack Mounted. (4) channels with audio/visual alarms for each channel. The sensitive area is 352 inches (230 cm2) for each detector. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Automatic Overhead Conveyor for Laundry or Hazmat Suits. On Hangers. Beta / Gamma High Sensitivity Detectors. Automatically separates ‘clean’ from ‘contaminated’ garments once scanned. Counts both sides of the garment simultaneously via two shielded detector towers. Four flat plastic scintillation sheets detectors in each tower, a total (of 8).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Small Animal Whole Body Counter. Ideal for laboratory use. Small live animals can be scanned, maintaining a repeatable counting geometry without harming the animal. Electronics PRS-7-DSC (Dual Single Channel Analyzer) built-in battery pack with charger. Dual detector connections. Use diverse detector types. Optional: Large animal chamber and port. Local readout and alarm.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable-Hand Carry, Cart Mounted.

High-Capacity Air Monitor. Detachable. Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, Noble Gas, and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Personal Mini-Air Monitor Series. Continuous. Miniature pump 1-3 lpm. Integrated exposure. (2) Options: (1) Mini-Air, Sampler only, no readout (2) Mini-Air-RAD, Sampler, and local readout. Full System (Big Bro) Total Airborne activity 6x10-8 uCi/cc in 30 minutes for Big Bro.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable, or Installed.

Water Test/Treat System. Alpha, Beta, and Gamma detection. BioSensor for Oxidation Reduction Potential (ORP) and Total Organic Carbon (TOC). Test and Treatment for radioactive and biological contamination. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring and treatment of drinking water 24/7. Facilities with multiple water inlets may wish to install multiple NEX-ABG-9TTs. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Benchtop. or Installed.

Water monitor for Beta isotopes: I-131, Sr-90/Y-90, Sr-89, Cs-137, Cs-134 etc. Continuous Real-Time Monitor drinking water against any and all Beta Emitter Contaminants except H-3, C-14, S-35 Monitor for contamination in-ground or surface water Monitor liquid waste stream from laboratory or plant.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable or Installed.

Water Monitor. Continuous Real-Time. Continuous. Detects Alpha, Beta, and Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Data archive/retrieval. Computer interface (3) Models:

  • (1) Portable with User’s electronics
  • (1) Installed with embedded processor
  • (1) Portable with embedded processor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital.

Alarming Pocket Dosimeter. Gamma dose rate and total exposure in a pocket-sized instrument. Audio and visual alarm. Built-In memory. Memory retention with dead or change out of battery for 20 hours. 700 hours of battery life, typical.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Complete Positron Air Monitoring System for PET (Positron Emission Tomography) facilities. Continuous. 9 detector channels. 2 are monitors. Detects Positron, Particulate Beta/Gamma Iodine, and Noble Gases. Local and remote readout, alarm, and monitoring. Data archive/retrieval. Computer interface. Easy integration into facility mainframe.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital.

This is a Photon Plasma Chamber® for an Area Monitor for a High Energy Accelerator. Two models: Installed, PLASMA-ACC and portable TBM-ACC-X. The ONLY accelerator plasma chamber® that will detect nanosecond pulsed X-Rays. It will accurately measure the integrated Total Dose from pulsed X-Ray machines over a wide range of pulse widths and repetition rates

  • PLASMA-ACC: Installed. AC power. Available in a multi-detector system. Data archive and retrieval. Local and remote read-out and alarm. Computer interface.
  • TBM-ACC-X: Portable. Battery power. Single detector system. Local digital read-out.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PPVM Series
Portal Monitors

Digital. Portable or Installed.

Personnel, Vehicle, Waste/Trash Portal Monitors. Two towers each with scintillation detectors. Weather-proof. Continuous operation ‘set and forget’. (5) Model options.

  • PPVM-TA: Total (2) scintillation detectors. (2) Towers. Portable or Installed, Walls, or Doorways. Freestanding, Fences,
  • PPVM-TA-P: Total (2) scintillation detectors. (2) Towers. Portable: Freestanding, Fences, Walls, or Doorways
  • PPVM-TA-3: Total (7) scintillation detectors. (2) Towers. (1) overhead detector. Has a Higher sensitivity than PPVM-TA.
  • PPVM-TA-5ES: Total (11) scintillation detectors. (2) Towers. (1) The overhead detector is designed for indoor use, hallways, and doorways.
  • PPVM-TA-1: Total (1) scintillation detector. (1) Tower.

Optional: Underfoot detector. Handheld Alpha/Beta Detector. Installed Neutron detector
Optional: Local and remote alarm, readout, and monitoring. Computer interface.
Optional: Wireless remote notification – phone, email, text, video recording.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable.

Quick Scan X-Ray Leak Detector. 8 GM detectors built into a 2-handled sweeper for large surfaces. Alarm lights for each detector. Locate the leak then mark the leak. Read leak emissions with X-Ray compliance meter TBM-IC-XRAY. Click Here For GM Pancake Tube Response Report 

 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed. Continuous.
Electronics; Portable or Bench Top.

Radon Air/Stack Monitor. Continuous. Highly sensitive and rugged. Dual-balanced ion chambers. measure airborne radon as free Radon gas (with or without Radon Daughters user’s option) as low as 1pCi/l. Local readout. Computer interface.
Click for Portable Radon Comparison Chart

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Fast – Slow Neutron Monitors.

  • PUG-7N-A. Analog. Detects fast or slow Neutrons by means of a thermal Neutron scintillation detector and a moderator. It is lightweight and includes the electronics, moderator, and probe. Use with GM or Scintillator detectors. Local readout.
  • PUG-7N-D. Digital. Portable.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable, Wall mount, or Benchtop.

  • OXY-IS-D AIR; Oxygen measurement for ambient oxygen in the air. Wall mount. Diffusion style. No pump. Local readout or Computer interface.
  • OXY-IS-DF AIR; Oxygen measurement for process oxygen. Wall mount or benchtop. Flow-through style. Quiet Air pump, 30 lpm.
  • Both OXY-IS-D and OXY-IS-DF; Dual scale 0-25%; 0-50%. Sensitivity 0.5% O2 in the air by volume. Local readout or Computer interface.
  • OXY-IS-DSUB WATER; Portable. Digital. Dissolved oxygen. Non-fouling cell diffusion style submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.
  • OXY-IS-DFW WATER; Dissolved oxygen. Non-fouling cell flows through submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable or Bench Top.

Liquid Scintillation Counting System. Detects all Alpha/Beta Emitters and Low Energy Gamma Emitters–Including; Tritium, Carbon-14, Sulphur-35, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Pelican Type Case, SSS-22-MCA, Multichannel Analyzer, suitcase version of SSS-22P (SSS-22PAL), lab version of SSS-22P (SSS-22LAB). Local readout and alarm. Computer interface. Optional: 6 sample adapters.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Flow Through Gas Proportional Monitor for Airborne Radiation. A highly sensitive Alpha, Beta, and Gamma flow through the gas counter. It consists of an internal gas proportional detector, mixing chamber, thermostat assembly, and a scaler, timer, and pulse height analyzer. Use as an accessory to a gas chromatograph. AC power. Audio/visual alarm. A user-settable alarm relay to control other devices. Data archive and retrieval. USB and Ethernet. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Analog. Portable.

Dual Detector Scintillation/Pancake TBM. Detects Alpha, Beta, Gamma, Iodine, Tc99m, and X-ray. Lightweight system. Internal 2-inch pancake GM detector downward looking window at bottom of the case with sliding shield protector. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Analog or Digital. Portable.

First Responder’s Radiation Detection Emergency Kit. Detects Alpha, Beta, Gamma, X-Ray, and Neutron. Rugged, lightweight system. Internal 2-inch pancake GM detector downward looking window at bottom of the case with sliding shield protector. Four external probes for detection of Alpha (PAS-8), low energy Gamma (PGS-3T), all Neutrons (PNS-20T), plus the Gamma Search Probe (PGS-3L). Local readout. Kit comes in a carrying case.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Gamma, X-Ray Survey Meter. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Gamma, X-Ray Survey Meter. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Gamma, X-Ray Survey Meter. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

X-Ray Compliance Test Meter. Detects low X-Ray energy scatter. Axially X-Rays or Below 15 Kev Gamma. Local Readout: 6 Digit-Rate, 8 Digit Integrate. Small, lightweight. Local readout. Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable. Analog.

Radiographic Survey Meter. Small, rugged, very lightweight one-hand operation three-range ratemeter with built-in speaker. It has an anti-saturation circuit. Measures Gamma and X-Rays. Reads out directly in mR/hr. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Integrated Ion Chamber. Detects X-Ray Pulse down to 0.2μR and 0.0001 mR to 10 R Total Dose. Local readout. Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Wide Range Ion Chamber. Alpha, Beta, Gamma, X-Ray. Detects X-Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. Local readout. ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

All Gammas Including Low Energy Gammas, Betas (C-14), and X-Rays. Detects Alpha, Beta, and Gamma. Local readout: 8-digit rate, 8-digit integration. Free Air ion chamber 5'' diam 7.5'' long. Internal volume 2 liters.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Fast, Rugged Ion Chamber. Detects Beta, Gamma, and X-Ray. Readout: 6 Digit-Rate, 8 Digit Integrate. The rate range is 0.1 mR/h to 50,000mR/h in a single range. The dose range is 0.01mR to 100R in a single range. Optional: Side view low energy (down to 20KeV) fluted chamber. TBM-IC-LE. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Alpha, Beta-Gamma, and X-Ray Surface Contamination Meter. Surface contamination monitor. Recommended by experts for the fire department and First Responder use. Local readout.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Plasma Chamber® for a High Energy Accelerator. The PLASMA-ACC is the only accelerator plasma chamber® that will detect nanosecond pulsed X-Rays over a wide range of pulse widths and repetition rates. Installed model – Plasma-ACC. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thyroid Uptake System. With or without well counter. Detects I-123, I-125, I-131, Tc-99m. Floor stand model TUM-1600 Standard. Optional: Tabletop model TUM-1600-T.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital, Installed.

In-Line Air Monitor. All-in-One. Continuous Real-Time. Automatic. Combines Multiple Detection Goals.

  • Radiation: Detects Alpha, Beta, Gamma, Optional: Tritium, Radon
  • Chemical: Major Chemical Tests CWA +TIC’s PH, ORP, and Lead
  • Chemical: Indicators of Biological Activity
  • Biological: Detects More Than 6 Classes of Microbes

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital, Installed.

All-in-One, In-Line Water Monitor. Continuous, Real-Time. Automatic. Combines Multiple Detection Goals into One Monitor. Data Archive / Retrieval; SCADA Compatible. Multi-Channel Analyzer and Library with 1024+ Channels. Local and Remote Display, Control, and Communications. No Reagents are Required Except for Trace Metals.

  • Biological Detection (18): Measures with (4) or more different biosensors
  • Chemical Detection (52): 7 or more major chemical tests provided or tailored to need including but not limited to: Turbidity, pH, Nitrates, and Chloride.
  • Trace and Heavy Metals (17): Including but not limited to Lead, Arsenic, and Cadmium.
  • Radiation Detection (5): Alpha, Beta, Gamma - Optional: Tritium, Radon.
  • Specific Detection, Analysis, and Measurement: Provides a critical guide for finding and correcting the upstream physical sources of contamination.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .