Waste Sites

The EPA has tough regulations when it comes to disposing of radioactive material. Scrap metal sites are at risk for substantial fines and returned scrap if it is found to be radioactive. Waste material sites that take in radioactive waste material must adhere to strict rules of detection and ongoing monitoring. Technical Associates, a division of US Nuclear Corp, has developed a suite of instruments designed specifically for the harsh environment of scrap metal yards and sites taking in radioactive waste.

MODEL

DESCRIPTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drone Flight Platform
UAV Air Forensics

Typical Features: Weather-resistant heavy-lift commercial UAVs. Automatic return to home, autonomous waypoint capability, intelligent flight modes, commercial-grade carbon fiber frame, GPS position and hold, Flight telemetry overlay, stable in 20 mph (32 km/h) wind. Optional: Sense and Avoid Payload up to 11 pounds, 6 commercial grade heavy-lift motor. Flight times up to 70 minutes, dependent on payload weight, speed 35 mph, (56 km/h), FPV camera, and real-time video downlink. USA made.

Fly Detectors Together or Separately. Optional: Cameras: User Specific Note: UAV Platform is Selected to Meet User’s Mission Requirements

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Plume detector. UAV-mounted DroneRAD System. Digital. Portable. Alpha, Beta, Gamma, C-14. Aerial radiation detector DroneRAD software, built-in air pump, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Air Monitor and Plume detection DroneRAD-P. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Search Tool fixed source-detector. UAV-mounted DroneRAD System. Gamma, optional Neutron aerial radiation detector, DroneRAD software, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Downward-looking Gamma and optional Fast Neutron spotters for ground, building, vehicle, and facility air surveillance. DroneRAD-ST. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DroneCHEM-LMC-TA
Laser Methane Detection

Digital. Portable.

UAV Mounted Laser Methane Detector. Optical laser detector. Distance up to 82 feet (25 meters). Detects a wide variety of airborne chemicals. Standard list available on Data Sheet. User-specific chemical detection is available. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

UAV mounted. Laser detects airborne methane. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface. Two UAV-mounted detectors: GPS Linked. Together detect airborne methane and locate and measure leaks.

  • DroneChem-Aero-MS
    Digital, portable or installed, battery or AC power, handheld. Local readout. User settable alarm (high or low) Detects multiple gases, with interchangeable sensor heads. Use for locating and measurement of leaks. Data archive/retrieval. Optional: remote sensor capability. Optional: temp and HR sensor.
  • DroneRAD-LMC-TA
    Digital. Portable. Laser detects airborne methane. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Beta / Gamma Particulate Monitor. T-1190 GM detector. Flow rate 70 lpm standard. The filter is under constant surveillance via a thin window GM pancake detector. FM-9-BG-C has a cyclone particle separator. Data archive/retrieval. Computer interface. Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Grapple or Crane Mounted Gamma and Neutron Radiation Detector and System. Suitable for any grapple or crane. No moving parts, and quick change between grapples or cranes. Display in the Grapple Operator cab. Optional: Wireless remote alarm and display to the base station.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

One Belt Laundry Monitor, extra sensitive, high speed. Uses eight gas flow detectors 6" x 16" and shift register and N of 8 electronics. Detects Beta-Gamma Radiation.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portal Monitors

Digital. Portable or Installed.

Personnel, Vehicle, Waste/Trash Portal Monitors. Two towers each with scintillation detectors. Weather-proof. Continuous operation ‘set and forget’. (5) Model options.

  • PPVM-TA: Total (2) scintillation detectors. (2) Towers. Portable or Installed, Walls, or Doorways. Freestanding, Fences,
  • PPVM-TA-P: Total (2) scintillation detectors. (2) Towers. Portable: Freestanding, Fences, Walls, or Doorways
  • PPVM-TA-3: Total (7) scintillation detectors. (2) Towers. (1) overhead detector. Has a Higher sensitivity than PPVM-TA.
  • PPVM-TA-5ES: Total (11) scintillation detectors. (2) Towers. (1) The overhead detector is designed for indoor use, hallways, and doorways.
  • PPVM-TA-1: Total (1) scintillation detector. (1) Tower.

Optional: Underfoot detector. Handheld Alpha/Beta Detector. Installed Neutron detector
Optional: Local and remote alarm, readout, and monitoring. Computer interface.
Optional: Wireless remote notification – phone, email, text, video recording.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable or Installed.

Gamma Silt and Particulate Raw Water Monitor. Raw Water Monitor Continuous Real-Time. Detects Gamma. Single detector RAWA-GP. Dual detector RAWA-BGP for Beta and Gamma. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Useful in complying with discharge requirements for wastewater. The modular system allows function changes or additions and rapid repair in the field.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top.

Liquid Scintillation Counting System. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Optional: 6 sample adapters. Six models:

  • 1 sample SSS-12P
  • 3 samples of SSS-22P,
  • 3 samples with a Multichannel Analyzer SSS-22-MCA,
  • All-in-one suitcase version: 3 sample systems and electronics - SSS-22PAL
  • SSS-22PAL-ID comes with MCA,
  • SSS-22-LR (Low Range Tritium).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Slip in a self-contained modular unit for a van or truck for mobile radiation detection. Choose up to 7 different detectors for simultaneous detection. Detects Beta-Gamma, and Neutrons. Optional: Targeted OMNI directional detector. Built-in GPS. Includes air and water sampling, MCA, electronics – computer hub – FM-9HUB. Local alarm, readout, and monitoring. Easy to use with Ethernet capabilities. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SWM-2021
Solid Waste

Digital.

Solid Waste Monitor. Transportable. Wide range Gamma detector. Front loading. Large volume scintillator. Holds 55 gallons, drums, or bags—load cell scale. Display Total sample activity or Activity per pound (kg). Local readout and alarm. Onboard archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-3SR-D
Surface Contamination

Digital. Portable,

TBM-3SR-D is a Surface Contamination Meter. Alpha, Beta-Gamma, X-Ray. Built-in 2" diameter pancake tube with sliding Beta shield and speaker. 0.01 to 100.00 mR/hr. Recommended by experts for the fire department and first responder use. Local readout. Optional: 2-way serial ports for computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-15D
Single Range Frisker

Digital. Portable.

Frisker- 4 Decades, Single Range Surface Contamination Meter with No Range Switching. Detects Alpha, Beta, Gamma, and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonaler. Local Readout. Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VMF-TA Series
Installed Vehicle Monitors

Digital. Installed.

Installed Vehicle Monitors. Pass between dual scintillation detectors. Local and remote alarm, readout, and monitoring. Computer interface. Optional: Neutron detector. Wireless remote notification – phone, email, text, video recording. 4 models:

  • VMF-TA and VMF-TB each have 528"scintillation area.
  • VMF-TB has higher sensitivity than VMF-TA.
  • VMF-4X doubles the sensitivity area.
  • VMF-4XO has an overhead detector.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .