Radon, Radium, Thoron

MODEL

DESCRIPTION

RADON IN AIR

ABG-NET Series
Networked or Stand
Alone Air Monitor

Networked or Standalone Air Monitor. Digital. Portable or Installed. Detects Alpha, Beta Particulates, Ambient Gamma. 1 or 2 channel options. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

  • ABG-NET: One channel
  • ABG-R-NET: Second channel for Radon Moving filter head.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thoron and Radon Gas Air Monitors. Alpha, Beta Particulate. FM-9-MA2 Series: Digital, Portable, Installed. Real-Time operation. Local or Remote Sampling and Read Out. Data archive/retrieval. Computer interface.

  • FM-9-MA2: Alpha Only
  • FM-9-MAB2: Alpha and Beta
  • FM-9-MAB2-M: Mobile. Moving filter head for FM-9-MAB2-M only.
  • FM-9-MA2-T: Gas Ion Chamber is added to the Alpha and Beta detector system.
  • FM-9-MA2-R Radon: Gas Ion Chamber is added to the Alpha and Beta detector system.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Multiuse Radiation and Chemical Air Monitor. Digital. Bench Top. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination is available. 1 each for a solid-state detector for Alpha and Beta particulates. Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FR-5-FS

 

The Rapid Radon Monitor. A System for Quick Measurement. A Collection Unit with a Quiet Pump and Charcoal Filter Holder with a Scintillation Counter/Scaler. Portable AC. 1 Picocurie Per Liter In 3 Minute Sampling. Increased Sensitivity with Longer Sampling. Replacement Cartridges Widely Available. PRS-7 Electronics. Battery or AC. Computer Interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Iodine Monitor Total Airborne Activity. Digital. Portable. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user-settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector.

FR-PII-Pb uses ½" lead shield. Use as industrial workplace and hospital breathing air measurement system, and to monitor fume hoods and stack effluent down to EPA levels. Line operated. Local readout. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Radon Air Monitor

Radon Air Monitor. Digital. Portable or Bench Top. Highly sensitive and rugged. Dual balanced ion chambers. measure airborne radon as free Radon gas (with or without Radon Daughters user’s option) as low as 1pCi/l. Local readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RANDFAN-SX
Radon Detect / Switch

Radon Detection and Mitigation Switch. Digital. Installed. Integrate into building HVAC system or stand alone. Radon sensor and activates or controls Radon mitigation devices. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RnCAM
Radon in Air

Portable Radon Monitor. Digital. Portable. Detects Radon-220 and Radon-222 at 10 Minutes. Longer the count times (30 Minutes), the greater sensitivity. Real-time display. Local readout. Data output via proprietary software to user's laptop. The internal data log establishes daily variation in Radon concentrations. Perfect for inspectors.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rn-EX-DET
Radon Expel Water and Gas System

Dual radon detectors and radon expel / water and gas system/monitor. Digital. Installed and portable. The system has two detectors. NexAlpha-R for Radon in Water (Installed) and the RnCAM for Radon in Air (Installed or portable.) FM-9W electronics include one display from the two detectors with a computer interface. Water moves through the NexAlpha-Rwhich measures Total Radon. The RnCAM measures Radon in air.

The system removes and cleans Radon from the water via a separator chamber. Radon gas is bubbled out of the water and enters the RnCAM air monitor for measurement. The cleaned water is directed from the separator chamber to the outlet drain. The RnCAM can be detached from the system and used as a portable Radon air monitor.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TBM-IC-RN
Fast Radon Detector

Portable Fast Radon Detector. Digital. Portable. Detects 10 picoCi/l in 5 seconds and detects public release level in less than 10 minutes. Small, lightweight. Drift-free electrometer technology. Measures ambient radon and no air pump is required. Local readout.
Click For Portable Ion Chamber Comparison Chart.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VADO-Zone/Soil

Radon Vapor Extraction Tool in the Soil and Monitor. Digital. Portable. Measures airborne Radon in any form: water vapor, hydrogen gas, or as volatile chemicals in concentrations. Rechargeable battery with built-in charger. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RADON IN WATER

NPP-H2O
Nuclear Power Water

Nuclear Power Water Monitor Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice Scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional:Tritium, C-14, Radon detection.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water monitor for Alpha isotopes: Most Alphas including U-238, Po-210, and Radon. Digital, Benchtop, or installed. Continuous Real-Time water monitor. Monitor for contamination of in-ground or surface water. Monitor liquid waste stream from hospitals, laboratories or plants, mining/oil/gas extraction, and Nuclear Power plants. Data archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Monitor Continuous Real-Time. Digital. Portable or Installed. Detects Alpha, Beta, Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface. (3) Models:

  • (1) Portable with User’s electronics
  • (1) Installed with embedded processor
  • (1) Portable with embedded processor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

NEXGEN-SSS
Drinking Water Monitor

Drinking-Water Monitor, Continuous Real-Time. Digital. Installed. Continuous. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the RAWA-GP option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
Optional: Ozone System. Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water). FAQ

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drinking/Waste Water

Drinking-Water and Wastewater Monitor. Digital. Rack Mounted or Wheeled Base. Continuous. Detects Gamma. Monitor ground, surface water, and industrial liquid-waste-stream. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Optional: Detectors: Alpha, Beta, Tritium, Radon. Optional: Submersible Gamma probe.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RADON-7
Portable Radon Water

Radon in Water. Analog. Portable. Radon Alpha Scintillation system and combines a modified PAS-8 Alpha Scintillation Probe plus FLO-9 water-flow-thru sampler. Monitor aquifer for rising Radon levels in complying with EPA and Water Districts standards.  Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SSS-33M8-R
Radon Water Monitor

Radon Water Monitor. Digital. Bench Top or Rack Mounted. Real-Time Continuous. Monitor laboratory or plant liquid waste stream. Sensitive to 200 pCurie/liter. Not influenced by other nuclides. Local readout. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RADIUM WATER MONITOR

Radium Series
Radium In Water

Radium in Water System. Digital. Portable or Installed. Detects Alpha. (2) modelsRADIUM-TA or RADIUM-MCA with Alpha Multichannel Analyzer. (2) Electronics options:

  • RADIUM-MCA – with MCA-TA (Multi-Channel Analyzer) and Semiconductor Crystal.
    Local readout, computer interface.
  • RADIUM-TA with PRS-7 digital scaler and ZnS(Ag) Scintillator. Local readout.
    Optional: computer interface.

Multiple components: Water Pump, radium collection cell, scintillation detector, electronics. Optional: In-Line Radium Detector Sensitivity 3 Pico curie per Liter Total Radium.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Radium in Water Removal System. Digital. Installed. Ion Exchange system for small water systems. The system Includes One TADR-M-150-2 progressive flow water softener with meter-controlled regeneration. (2) 5 cubic foot steel resin tank. (2) MVP control. (2) Meter assembly and cable. (1) Brine (salt storage tank) 24 x 50. (1) Initial salt fill (400 lbs/ten 40 lb bags). Flow Rate: Typical 500 GPM, Total Flow:7,500 gallons per day. Installation is available in the USA.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

UNITECT-H2O
Integrated Water Monitor

Integrated Chemical, Biological, and Radiation Water Robust Monitoring System. Continuous Real-Time. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .