Model
Description
Catalog Page
TBM-IC-LR
Low Range Gammas and Betas
Low Range Ion Chamber. Digital. Portable. Measures Alpha, Beta, Gamma, and X-Ray. All Gammas Including Low Energy Gammas, Betas (C-14), and X-Rays. Detects X-Ray pulse down to 0.002 μR. Measures down to the background. Measures all Gammas including low-energy Gammas and X-Rays. Sees axially below 5 KeV Gamma or X-Rays. Wide range 0.1 mR/hr to1,000R/hr. Local readout: 8 digit-rate, 8-digit integration. Free Air ion chamber. Internal volume 2 liters. ANSI N42.33 Homeland Security Type 2. Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-MVR
TBM-IC-LE
Fast, Rugged Ion Chamber
Fast, Rugged Ion Chamber. Digital. Portable. Detects Beta, Gamma, X-Ray. Digital. Readout: 6 Digit-Rate, 8 Digit Integrate. Rate range is 0.1 mR/h to 50,000mR/h in a single range. Dose range is 0.01mR to 100R in a single range. Side view low energy (down to 20KeV) fluted chamber. TBM-IC-LE Local readout.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-MARK-V
Gamma, X-Ray Survey Meter
Ion Chamber Survey Meter. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-PULSE-X
Nanosecond Pulsed X-Ray Detection
Nanosecond Pulsed X-Ray Detection. Digital. Portable. The ONLY radiology imaging portable for nanosecond detection. Measures integrated Total Dose from pulsed x-ray machines over a wide range of pulse widths and repetition rates. Local readout. MEETS 10CFR 34.25 - Federal Requirements for Radiation Survey Instruments. FAQ.
Click to See Reports.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-RN
Fast Radon Detector
Portable Fast Radon Detector. Digital. Portable. Detects 10 picoCi/l in 5 seconds and detects public release level in less than 10 minutes. Small, lightweight. Drift-free electrometer technology. Measures ambient radon and no air pump is required. Local readout.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-XRAY
X-Ray Compliance Test Meter
X-Ray Compliance Test Meter. Digital. Portable. Detects low x-ray energy scatter. Axially x-rays or below 15 KeV Gamma. Local readout. 6 Digit-Rate, 8 Digit Integrate. Small. Lightweight.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TOTAL-6
Stack Monitors
Stack Monitor. Digital. Installed. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium, and C-14 with a focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Data archive/retrieval. Local and remote alarming and monitoring. A Commercial version is available for research labs, room air, glove boxes, and other applicable uses.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TriCair
Tritium and Carbon 14
Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Read out. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRI-DECON
Tritium Decontamination
Tritium Decontamination System. Digital. Installed. This miniature Tritium Gas Removal system has high efficiency with convenience and ease of use. It provides a rugged system for harsh environments. Two electronics options: Model 357: to 1.0 µCi/m3 and Model 347: to 0.5 µCi/m3. Inlet and outlet hoses provide easy decontamination of fume hood, exhaust stack, etc interiors. Powered by a Rechargeable battery with a built-in charger. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tri-Per
Tritium Permeation Leak Detector
A Tritium Permeation Leak Detector. Digital. Portable. An ion chamber designed to seal to any type of cylindrical tank wall regardless of tank diameter via pliant air-tight rubber seals. Detects Tritons migrating through the wall of a Tritium Gas Tank. Internal air pump. Battery or AC operation. Audio and visual alarm. Optional: High-level alarm. Local readout. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRIMARAN-AIR and STACK
Ultra-Low Level Tritium Air
Ultra Low-Level Automated Tritium Air and Stack Monitor. Digital. Installed. Designed for near real-time ultra-low level Tritium detection in Nuclear Power Plants using sample enrichment & proportional counting. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRIMARAN H2O-ES
Ultra Low-Level Tritium in Water
Ultra Low-Level Tritium Water Continuous Real-Time Monitor. Digital. Installed. Designed for near real-time ultra-low-level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Trimaran-H2O-ES has enhanced sensitivity in a shorter time period. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRIATHALON Series
Tritium Ultra Low
Ultra Low Range Tritium Monitor. Digital. Installed or Rack Mounted. Highly sensitive, Tritium and C-14, real-time continuous. rugged stack or effluent monitor. Designed for Nuclear Power Plants. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface. The commercial version is available for research labs, room air, glove boxes, and other applicable uses.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tritium-AIR
Analyzer – Low-Level Tritium
Tritium-Air. Digital. Table Top, Rack mounted, or Free Standing. Continuous real-time monitoring. Designed to analyze Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. This system consists of an efficient condenser that pulls Tritiated water vapor from the air. AC power. Data archive and retrieval for up to five years. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tritium-AIR
Analyzer – Low-Level Tritium
Tritium-Air. Digital. Table Top, Rack mounted, or Free Standing. Continuous real-time monitoring. Designed to analyze Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. This system consists of an efficient condenser that pulls Tritiated water vapor from the air. AC power. Data archive and retrieval for up to five years. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tritium Tritides
Flow-Through Liquid Scintillation System, Digital. Portable. Measurement of Tritium and Tritium Tritides. AC/DC power. Pump and Mass Flow Sensor. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TUM-1600 and TUM-1600-T
Thyroid Uptake Monitor
Thyroid Uptake System. Digital. Portable. Floor Stand or Tabletop. Floor stand model TUM-1600 Standard. Optional: Tabletop model TUM-1600-T. Articulating arm for a wide reach. Detects I-123, I-125, I-131, Tc-99m. 1024 Channel MCA with isotope library. Touch screen. Data archive and retrieval. Computer interface. Optional: Print out. Dicom interface for patient data. With or without a well counter. Optional: 1-inch or 2-inch well cavity.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNITECT-H2O
Integrated Water Monitor
Integrated Chemical, Biological, and Radiation Water Robust Monitoring System. Continuous Real-Time. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNITECT-AIR
Integrated Air Monitor
Integrated Air Monitor: Radiation, Chemical, Biological. Digital. Installed. Robust, Continuous Real-Time. Monitoring System. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, Biological. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
URANIUM-TA Series
Uranium in Water
Uranium-TA Series Water Monitor. Two types of electronics. A single-channel analyzer is in both the portable and installed models of the Uranium-TA. The Installed version has the option to use the multi-channel analyzer, Uranium-MCA. Perfect for in-the-field use at fracking sites, uranium mines, and Super Fund clean-up sites. The PRS-7 electronics works with both versions of the Uranium-TA, portable and installed. Powered by AC or rechargeable batteries. Optional: Computer interface and Alarm Relay. The model Uranium-MCA is a benchtop electronics package with a customer-tailored radionuclide library. Data archive and retrieval. Powered by AC and internal batter backup. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VAP-X-(H3)
Tritium
Tritium Vapor Extraction Tool in the Soil and Monitor. Digital. Portable. A sensitive, rugged, instrument for the detection and measurement of Tritium vapor in the soil. Map underground plume and detect leak source. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VAP-X-Radon
Vado-Zone
Radon Vapor Extraction Tool in the Soil and Monitor. Digital. Portable. Measures airborne Radon in any form: water vapor, hydrogen gas or volatile chemicals in concentrations. Rechargeable battery with built-in charger. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installed Vehicle Monitors
Installed Vehicle Monitors. Digital. Installed. Pass between dual scintillation detectors. Local and remote alarm, readout, and monitoring. Computer interface. Optional: Neutron detector. Wireless remote notification – phone, email, text, video recording. 4 models:
- VMF-TA & VMF-TB each have 528"2 scintillation area.
- VMF-TB has higher sensitivity than VMF-TA.
- VMF-4X doubles the sensitivity area.
- VMF-4XO has an overhead detector.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The portable 4650 zNose® is the first and only FIELD READY chemical, organic, and biological compounds analyzer and identifier. Includes a fully integrated computer for in-field real-time analysis and identification. Its hydrocarbon detector speciates and quantifies organic compounds from C-4 to C-24 in 30 – 60 seconds or less. Identifies vapors as low as ppb for many compounds. Diverse applications from explosives to food and beverages. Easy to use.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .