Model
Description
Catalog Page
Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, mass flow controllers, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-3 Series
Surface Contamination Monitors
Surface Contamination Monitors. Analog. Portable. Detects Alpha, Beta-Gamma, and X-ray. 3 range ratemeters. 3 models. Recommended by experts for fire department and first responder use. Local readout.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-3D-PAS-9
6 Decade
Six Decade Scaler/Ratemeter Survey Meter. Digital. Portable. PAS-9: Alpha Scintillation Probe. TBM-3D electronics works with all of Technical Associates GM, Proportional, and Scintillation probes including those for X-Ray and Positron. Local readout. Optional: alarm, computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-3R
Radiographic Survey Meter
Radiographic Survey Meter. Analog. Portable. Small, rugged, very light weight one hand operation three range ratemeter with built-in speaker. It has an anti-saturation circuit. Detects Gamma and X-Rays. Reads out directly in mR/hr. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-3R-D
Radiographic Survey Meter
Radiographic Survey Meter. Digital. Portable. Small, rugged, very lightweight one-hand operation three-range ratemeter with built-in speaker. It has an anti-saturation circuit. Detects Gamma and X-Rays. Reads out directly in mR/hr. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-3SR-D
Surface Contamination
TBM-3SR-D is a Surface Contamination Meter. Digital. Portable, Alpha, Beta-Gamma, X-Ray. Built-in 2" diameter pancake tube with sliding Beta shield and speaker. 0.01 to 100.00 mR/hr. Recommended by experts for the fire department and first responder use. Local readout. Optional: 2-way serial ports for computer interface.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wide Range Alpha, Beta, Gamma Survey Meter. Analog. Portable. 5 RANGES: 0-0.2, 2, 20, 200, 2000mR/h. Energy compensated. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SP
Gamma Micro/Neutron Analyzer
Gamma Micro Meter plus Neutron Analyzer. Digital. Portable. Dual readout with Gamma in μ R/hr and Neutrons in cps. Designed specifically for use by inspectors and guards, police, and hazmat squad to give warning in case of illicit or accidental storage or transport of radioactive and fissile material. Optional: telescoping wand. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6GN
Gamma Micro/Neutron Analyzer
Gamma Micro Meter plus Neutron Analyzer. Digital. Portable. Dual readout with Gamma in μ R/hr and Neutrons in cps. Designed specifically for use by inspectors and guards, police, and hazmat squad to give warning in case of illicit or accidental storage or transport of radioactive and fissile material. Optional: telescoping wand. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SPE-D
First Responder’s Kit
First Responder’s Radiation Detection Emergency Kit. Portable. Digital. Detects Alpha, Beta, Gamma, X-Ray, and low-energy Neutrons. Rechargeable batteries and charger. Rugged, lightweight system. Local readout. The kit comes in a self-contained carrying case. Five external probes for detection: TBM-6SPE-D. A favorite of First Responders.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SP-ST
Search Tool
Surface Monitor / Search Tool. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Internal 2-inch pancake GM T-1190 detector downward looking window at bottom of the case with sliding shield protector. External Model PGS-3 1'' x 1'' scintillation probe for use as a Gamma Search Tool and µ R Meter. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6U-SV
Gamma Micro-R-Meter
Gamma Micro-R-Meter. Analog. Portable. Internal scintillation detector. Engineering units are µSv/h. Optional: mR/h. External probe with BNC connector. Internal and external probe circuits are switch selectable and independently calibrated. Optional: the second probe may be any GM, scintillation, or gas flow. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-15
3 Range Frisker
Frisker 3 Range Surface Contamination Meter. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonalert. Local Readout.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-15D
Single Range Frisker
Frisker- 4 Decades, Single Range Surface Contamination Meter with No Range Switching. Digital. Portable. Detects Alpha, Beta, Gamma, and X-Ray. External probe. One or two-handed use. Built-in probe holder. Small, lightweight. Sonaler. Local Readout.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-20S
Beta /Gamma Survey
Beta and Gamma Survey Meter. Analog. Portable. Small, lightweight three-range. Ratemeter with built-in GM tube and speaker. One-hand operation. Local readout. Reads out in mSv/h (or mR/h).
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-23 Series
3 Range Ratemeter
Three-range ratemeter. Analog. Portable. Reads out in cpm or mR/hr. Detects Alpha, Beta, and Gamma Radiation.
- TBM-23-W has an extendable 33'' long wand with a recessed and protected GM detector on the end.
- TBM-23-LB reads Low Background. Use for Column monitoring chromatogram plate monitoring: general purpose monitoring.
Survey/Sampler
3 Range Ratemeter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The Low Background TBM. Used for Column monitoring chromatogram plate monitoring: general purpose monitoring.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Floor Monitor
Floor Monitor. Digital. Portable. Detects Alpha, Beta, and Gamma. (4) models: (1) GM pancake detector, swivel head, with a 1.2-meter wand with separable, small, three-range ratemeter TBM-28 and TBM-28-15. (4) GM pancake detectors, swivel head, with a 1.2-meter wand with separable, small, three-range ratemeter TBM-28/4 and TBM-28/4-15. Additional short handles included TBM-28-15 and TBM-28/4-15. Local readout and alarm.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-55
Beta/Gamma Telescopic
Low to High Range Beta/Gamma Hand Held and Telescopic Probe. Digital. Portable. 3 Models: TBM-55-LR, Low Wide Range TBM-55-W, Wide Range. TBM-55-HR, High, Narrow Range. PRS-2S electronics have a ruggedized dual-meter readout. Battery operated with a probe holder attachment. Lightweight, compact size permits easy to transport and use. Local readout.
The TBM-55-W, Wide Range. TBM-55-HR, High, Narrow Range. probes have an extendable telescopic 6 oz. wand to 5 ½ feet. Optional: extendable wand to 10 ½ feet, 24 oz.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High Energy Accelerator Plasma Chamber® Area Monitor. Digital. Two models: Installed, PLASMA-ACC and portable TBM-ACC-X. The ONLY accelerator plasma chamber® that will detect nanosecond pulsed X-Rays. It will accurately measure the integrated Total Dose from pulsed X-Ray machines over a wide range of pulse widths and repetition rates
- PLASMA-ACC: Installed. AC power. Available in a multi-detector system.Data archive and retrieval. Local and remote readout and alarm. Computer interface.
- TBM-ACC-X: Portable. Battery power. Single detector system. Local digital readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-AJI
Integrating Ion Chamber
Integrating Ion Chamber. Digital. Portable. Free Air ion chamber 3.7'' dia x 6'' long. The internal volume is almost one liter. High sensitivity for Alphas and low energy Betas such as C-14. Also detects higher energy Betas and Gammas and X-rays down to 2 KeV. The TBM-IC-AJI ion chamber is lightweight and stable with essentially drift-free electrometer technology. Optional: RS232 Serial Port. Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-HLS
Wide Range Ion Chamber
Wide Range Ion Chamber. Digital. Portable. Alpha, Beta, Gamma, X-Ray. Detects X-Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. Local readout. This very wide range conforms to ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .