Model

Description

Catalog Page

Water monitor for Alpha isotopes: Most Alphas including U-238, Po-210, and Radon. Digital, Benchtop, or installed. Continuous Real-Time water monitor. Monitor for contamination of in-ground or surface water. Monitor liquid waste stream from hospitals, laboratories or plants, mining/oil/gas extraction, and Nuclear Power plants. Data archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Test/Treat System. Digital. Portable or Installed. Alpha, Beta, Gamma detection. BioSensor for Oxidation Reduction Potential (ORP) and Total Organic Carbon (TOC). Test and Treatment for radioactive and biological contamination.

Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring and treatment of drinking water 24/7. Facilities with multiple water inlets may wish to install multiple NEX-ABG-9TTs. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Monitor. Continuous Real-Time. Digital. Portable or Installed. Detects Alpha, Beta, Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface. (3) Models:

  • (1) Portable with User’s electronics
  • (1) Installed with embedded processor
  • (1) Portable with embedded processor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water monitor for Beta isotopes: I-131, Sr-90/Y-90, Sr-89, Cs-137, Cs-134 etc. Digital, Benchtop, or installed. Continuous Real-Time Monitor drinking water against any and all Beta Emitter Contaminants except H-3, C-14, S-35 Monitor for contamination in-ground or surface water Monitor liquid waste stream from laboratory or plant. Data archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drinking/Waste Water Monitor. Digital. In-Line or transportable (Rack Mounted or Wheeled Base). Continuous Real-Time. Detects Gamma. Monitor ground, surface water, industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TI) OR HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Use NEXGAMMA-2-SEA in Salt Water / Harsh Environments. Five models from which to choose. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

  • Optional: Detectors: Alpha, Beta, Tritium, Radon
  • Optional: Submersible Gamma probe

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

  • Optional: Ozone System.
  • Optional: Tritium detection.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Drinking-Water Monitor. Digital. Installed. Real-time continuous multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. FAQ

  • Optional: Ozone System.
  • Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium Water Monitor. Digital. Bench Top or Rack mounted. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Meets EPA drinking water levels. Strategy for Measurement of Tritium in Water / Oil Mixture.

  • Monitor Leaks in Candu Type Reactors
  • Monitor Tritium Contamination in Ground Water.
  • Monitor Laboratory or Plant Liquid Waste Stream.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dual Detector Wide Range Gamma Pocket Dosimeter. Digital and Analog. Portable. Detects Gammas, X-Rays. Alarming Gamma Rate and Dose Meter. Dual detector: Scintillator and Silicon Semiconductor. Dose and dose rate. Rugged, dust and water proof. function. Rechargeable batteries. EMF interference resistant. GPS search tool. Excellent for police, first responders, airport, and security personnel. USB.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Water Monitor. Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, and Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection. Strategy for Measurement of Tritium in Water / Oil Mixture.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wide Range Gamma Pocket Dosimeter. Digital. Portable. Compact, lightweight, impact resistant with long battery life. EMF interference resistant. Measures dose equivalent. Data download via reader.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gamma, X-Ray, Neutron Pocket Dosimeter. Digital. Portable. Dose and dose rate. Compact, lightweight, impact resistant with long battery life. EMF interference resistant. Data download via reader.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gamma, Beta, and X-Ray Pocket Dosimeter. Digital. Portable. Compact, lightweight, impact-resistant with long battery life. Measures dose equivalent. EMF interference-resistant. Data download via reader.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The NSN3 Neutron Survey Meter is designed for Nuclear Reactors, Neutron Sources and Generators, customs inspections, etc. Portable, light weight with fast count and zero drift. Measures ambient dose equivalent and ambient dose rate equivalent of neutrons.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ORO

Overhoff Radiation Overview. Digital. Installed. Map the facility in a series of views linking multiple instruments, installed and portable, and readings from a variety of areas to the facility mainframe and/or individually in each area including the perimeter. Software package: readout, mapping, reporting. Easy integration into facility mainframe. Wide variety of reports available.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • OXY-IS-D AIR; Oxygen measurement for ambient oxygen in the air. Wall mount. Diffusion style. No pump. Local readout or Computer interface.
  • OXY-IS-DF AIR; Oxygen measurement for process oxygen. Wall mount or benchtop. Flow-through style. Quiet Air pump, 30 lpm.
  • Both OXY-IS-D and OXY-IS-DF; Dual scale 0-25%; 0-50%. Sensitivity 0.5% O2 in the air by volume. Local readout or Computer interface.
  • OXY-IS-DSUB WATER; Portable. Digital. Dissolved oxygen. Non-fouling cell diffusion style submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.
  • OXY-IS-DFW WATER; Dissolved oxygen. Non-fouling cell flows through submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .