Model

Description

Catalog Page

Quick Check Water Monitor. Digital. Portable. Two detectors. (1) Internal-T-1190 Alpha, Beta, Gamma detector with a sliding Beta shield. (1) External-submersible Gamma detector. Local readout. Ranges: 4 linear for each detector:

  • 0-500; 5,000; 50,000; 500,000 cpm for external
  • 0-0.15; 1.5; 15; 150 mR/hr. for internal detector

Other scales and overlays available: Sieverts, etc. Use anywhere. Great for First Responders. Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

METHANE-TA Series
Methane Leak Detector

  • Methane-TA1 Digital. Portable. Battery operated. Hand held. Data archive/retrieval. Computer interface. Local readout. User settable alarm. Detects multiple gases, user settable.
  • Methane-TA2 Digital. Portable or installed. Battery or AC power. Hand held. Local readout. User settable alarm (high or low) Detects multiple gases, with interchangeable sensor heads. Data archive/retrieval. Computer interface. Optional: remote sensor capability. Optional: temp and HR sensor.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

High-Capacity Air Monitor. Digital. Portable-Hand Carry. Cart Mounted. Detachable. Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, and Noble Gas and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Personal Beryllium-Air Sampler. Digital. Portable. Continuous. Miniature pump 1-3 lpm. Integrated exposure. Collection of Beryllium particulates. On board memory for data retrieval via data access. Uses 47 mm or 140 mm filters. User specified. USB, rechargeable batteries, and charger.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Personal Mini-Air Monitor Series. Digital. Portable. Continuous. Miniature pump 1-3 lpm. Integrated exposure. (2) Options: (1) Mini-Air, Sampler only, no readout (2) Mini-Air-RAD, Sampler, and local readout. Full System (Big Bro) Total Airborne activity 6x10-8 uCi/cc in 30 minutes for Big Bro.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Chemical, Biological, and Radiation Water Safety Monitor. Digital. Portable. Solar Powered. Real-Time Continuous detection of 4-6 Radionuclides, 6 major chemical contaminants, Total Fecal, and E-Coli Bacteria. USB port for data downloads to PC or Tablet. Suitcase model in wheeled case MiniTect-H2O-SC. Backpack model = (2) backpacks MiniTect-H2O-BP.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Moving Filter Head for Alpha and Beta in a variety of air monitors.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mobile High Volume Cart Mounted Beryllium Air Sampler and Totalizer. Digital. Portable. Draws the room air in onto quick-change filters, 47mm or 147mm diameter glass fiber filters. Adjustable breathing air intake height. Inlet/outlet hose provides versatility for hoods, glove boxes, stacks, etc. Optional: Battery power. Standard air flow is 10-100 lpm. Optional: 227 lpm with a quiet Green Turtle pump.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mobile High Volume Cart Mounted Air Sampler and Totalizer. Digital. Portable. Draws the room air in onto quick-change filters, 2"- 4" or 4"- 8" Mobl-Air-8. Adjustable breathing air intake height. Inlet/outlet hose provides versatility for hoods, glove boxes, stacks, etc. Optional: Battery power. Standard air flow is 48-200 lpm with a quiet Green Turtle pump.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium survey monitor. Portable. Digital. No zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO discriminating version. Local display.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Highly sensitive tritium air monitor Digital. Portable. Includes four-21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model 357 Tritium in air monitor. Digital. Portable. General-Purpose. Dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarm. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium in air monitor. Digital. Portable. Gamma compensated. High sensitivity and stability Rapid response. Four 200cc ion chambers: Two ion chambers are used for measurement (400cc total) and two for gamma compensation (400cc total). NiMH rechargeable batteries. Optional: AC adapter. RS232 Data output. CE Marked.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ultra-Sensitive Tritium in Water Monitor. Heavy water leak detector. Installed. Digital. Fully automated, real-time, and continuous. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water. Integrated computer with custom software and large LCD display. Monitors water below the EPA drinking water standard of 20,000 pCi/l. The Model 1925-PR-SEA includes sample preparation and robust plumbing to withstand salt water. Computer interface with ethernet and USB.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Molten Salt Thorium Reactor Water Monitor. Real-Time Continuous. Digital. Installed. Detects Thorium, Tritium, Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .