Quick Response Plutonium Air Monitor. Digital. Portable. Electronics; Portable or Bench Top. Sees Alphas and Betas in high or varying background situations. Two different detectors. Stand alone or networked with other detection locations. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Tritium and C-14 Surface Contamination Meter. Digital. Portable. Gas flow proportional detector. Use for flat surfaces. 100cm² sensitive area. Local readout. Optional: probe for hands, clothing, and equipment.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wide Range Area Monitor. Digital. Portable. Bench Top. Rack Mount. Wall Mount, or NEMA cabinet for hostile environments. Detects Gamma and Beta. Electronics: digital alarm ratemeter LAM-10D, built in battery pack with charger, electrometer and ion chamber.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Food and Cosmetic Monitor. Digital. Bench Top. Measure radioactive contamination in all types of food, cosmetics, or other bulk samples. One-liter capacity scintillation well detector. Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Neutron REM Area Air Monitoring System. Digital. Installed or Rack Mounted. Moderated proportional BF3 neutron tube. Use for tracking the level of Neutron radiation present in and around nuclear reactors, accelerators, neutron sources, generators, etc. Optional: multi-channel system. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Alpha/Beta/Gamma/Beryllium Air Monitor. Digital. Portable or Bench Top. Continuous.

  • FM-9-AB2: 2 detectors (1) GM Pancake. (1) Scintillator.
  • FM-9-AB2-Be: added Beryllium filters. Flow rate 70 lpm standard, user settable. Local Readout. Data archive/retrieval. Computer interface

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Beta / Gamma Particulate Monitor. Digital. Portable. T-1190 GM detector. Flow rate 70 lpm standard. The filter is under constant surveillance via a thin window GM pancake detector. FM-9-BG-C has a cyclone particle separator. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PET, Iodine, Tc-99m DTPA Air Monitor. DigitalPortable. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Application: Hospitals / Research, Power Plants, National Labs

Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The FM-9-ABGN uses a standard filter in TA's unique quick change, with no leak holder to trap any airborne particulates. The filter is under constant surveillance via a thin window GM pancake detector.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FM-9HUB

 

Computing engine for multiple instruments and systems. Wall mount, digital.

  • Powers channels for multiple instruments: air, water, area, vehicle, and personnel.
  • Continuous, real-time, rugged duty.
  • Includes computer and color monitor.
  • Easy integration to facility mainframe if desired.
  • Single-channel to 20 channels

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Multiuse Radiation and Chemical Air Monitor. Digital. Benchtop. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination available. Detectors for Alpha and Beta particulates; 1 each. Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

  • Applications: radiation and chemical air monitoring for the workplace of stack effluent, hoods, glove boxes, room, and environmental air
  • Optional Sensors: temperature, thermal, and relative humidity

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Thoron and Radon Gas Air Monitors. Alpha, Beta Particulate. FM-9-MA2 Series: Digital, Portable, Installed. Real-Time operation. Local or Remote Sampling and Read Out. Data archive/retrieval. Computer interface.

  • FM-9-MA2: Alpha Only
  • FM-9-MAB2: Alpha and Beta
  • FM-9-MAB2-M: Mobile. Moving filter head for FM-9-MAB2-M only.
  • FM-9-MA2-T: Gas Ion Chamber is added to the Alpha and Beta detector system.
  • FM-9-MA2-R Radon: Gas Ion Chamber is added to the Alpha and Beta detector system.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Use for the stack, hood, glove box, or area air. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Xenon-133 Gas Monitor. Digital. Installed. Continuous. Flow rate 10 lpm standard. Local readout. Pre-filter removes particulates. Local Readout. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PET, Iodine, or Tc-99m DTPA Air Monitor. Digital. Bench Top. Multi-Channel Analyzer (MCA). Continuous. Monitor air room or stack effluent. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Iodine-125 Air Gas and Particulate Air Monitor. Digital. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard.

Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent. Bench Top or Cart Mounted

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Beta Particulate Air Monitor System. Digital. Bench Top. Continuous. 2 GM detector system. (1) Beta Particulates, (1) for Dynamic Background Subtract. Integrated exposure. Local and remote continuous real-time sampling. Quick change filter. Electronic Mass Flowmeter. Data archive/retrieval. Computer interface.

Expandable system with FM-9 series modules.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Noble Gas, Argon, Xenon, Krypton Monitor, or Leak Detector. Digital. Installed, Cart Mounted, or Benchtop. Real-time, continuous, digital display. Five models to choose from include the cart-mounted FM-9XE-NGL Leak Detector and the 10 scintillation detector model FM-9NGAS-10S. Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wide Range Beta-Gamma GM Area Monitor. Single or Multi-Channel. Digital. Rack or Wall mount. For in and around nuclear reactors, hot cells irradiators, and other facilities handling radioactive materials or x-rays. Local or Remote monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wide Range Area Monitor. Digital. Bench Top or Installed. Detects Beta, Gamma, X-Ray. Optional: Neutron. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Use with wide range of TA detector types. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Radiation Control Monitor. Digital. Bench Top or Installed. Exit/Doorway Monitor/Package/Mail Monitor/Vehicle Monitor/Laundry Monitor. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Nuclear Power Plant Process Monitor. Digital. Rack Mounted. Safety Class Qualified for NPP use. Detects Gamma, rejects thermal Neutron, Alpha, Beta. High pressure sealed ionization chamber with mineral insulated cable. (2) Electronics: Single or multichannel. (1) single channel FM-9W. (1) multichannel FM-9WHUB. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wide Range Beta-Gamma GM Area Monitor. Single or Multi Channel. Digital. Rack or Wall mount. For in and around nuclear reactors, hot cells irradiators and other facilities handling radioactive materials or x-rays. Local or Remote monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FPT-H3 Series
Fuel Pool Tool

Fuel Pool Tool. Detects Tritium in NPP pool water, and pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only FPT-H3. (1) Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Portable Radon Monitor Systems. Used to determine the radon content of the air in basements, mills, mines, buildings, or anywhere radon concentration is a concern.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The Rapid Radon Monitor. A System for Quick Measurement. A Collection Unit with a Quiet Pump and Charcoal Filter Holder with a Scintillation Counter/Scaler. Portable AC. 1 Picocurie Per Liter In 3 Minute Sampling. Increased Sensitivity with Longer Sampling. Replacement Cartridges Widely Available. PRS-7 Electronics. Battery or AC. Computer Interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FR-PIB Series
Iodine Total Air Activity

Iodine Monitor Total Airborne Activity. Digital. Portable. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector. Line operated. Local readout. Data archive/retrieval. Computer interface.

FR-PII-Pb uses ½" lead shield. Use as industrial workplace and hospital breathing air measurement system, and to monitor fume hoods and stack effluent down to EPA levels.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Lightweight Digital Frisker. Dual GM Pancake Sensors in paddle form with handle. Battery operated. Gamma detection. Portable. Electronics: PRS-2. 2 Separate scale factors for Rate and Total. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .