Model
Description
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable.
Fast – Slow Neutron Monitors. PUG-7N-A. Analog. Detects fast or slow Neutrons by means of a thermal Neutron scintillation detector and a moderator. It is lightweight and includes electronics, a moderator, and a probe. Use with GM or Scintillator detectors. Local readout.
PUG-7N-D Digital. Portable.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital. Portable.
Nanosecond Pulsed X-Ray Detection. The ONLY radiology imaging portable for nanosecond detection. Measures integrated Total Dose from pulsed x-ray machines over a wide range of pulse widths and repetition rates. Local readout. Meets 10CFR 34.25 - Federal Requirements for Radiation Survey Instruments. FAQ. Click to See Reports.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital. Portable.
Gamma, X-Ray Survey Meter. Detects Alpha, Beta, Gamma, and X-Ray. Fast, sensitive ion chamber. Affectionally referred to as the ‘Cutie Pie’. Small, lightweight. Drift-free electrometer technology. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital. Portable.
Integrated Ion Chamber. Detects X-Ray Pulse down to 0.2μR and 0.0001 mR to 10 R Total Dose. Local readout.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital. Portable.
Wide Range Ion Chamber. Alpha, Beta, Gamma, X-Ray. Detects X-Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. Local readout. ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-LR
Low Range Gammas and Betas
Digital. Portable.
Low Range Ion Chamber. Measures Alpha, Beta, Gamma, and X-Ray. All Gammas Including Low Energy Gammas, Betas (C-14), and X-Rays. Detects X-Ray pulse down to 0.002 μR. Measures down to the background. Measures all Gammas including low-energy Gammas and X-Rays. Sees axially below 5 KeV Gamma or X-Rays. Wide range 0.1 mR/hr to1,000R/hr. Local readout: 8 digit-rate, 8-digit integration. Free Air ion chamber. Internal volume 2 liters. ANSI N42.33 Homeland Security Type 2. Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital. Portable.
Fast, Rugged Ion Chamber. Detects Beta, Gamma, and X-rays. Digital. Readout: 6 Digit-Rate, 8 Digit Integrate. The rate range is 0.1 mR/h to 50,000mR/h in a single range. The dose range is 0.01mR to 100R in a single range. Optional: Side view low energy (down to 20KeV) fluted chamber. TBM-IC-LE. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital. Portable.
Alpha, Beta-Gamma, and X-Ray Surface Contamination Meter. Surface contamination monitor. Recommended by experts for the fire department and First Responder use. Local readout. Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .