NEUTRON, C-14, Tc99m, PLUTONIUM
MODEL
DESCRIPTION
BAM-STAM-3Z Series
Portable Alpha, Beta, Gamma
Portable Alpha, Beta, Gamma. Portable. Digital. Rugged, cart-mounted (detachable). Two detector systems. Optional: Three detector system BAM-STAM-3ZG. Alpha, Gamma, Plutonium. Counts wipes, filters, and planchets. Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARB-F-9 Series
C-14/Iodine Air/Stack
High-Range Submersible Monitors. Digital. Portable. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven Model CP-MU coupled to specific ion chamber detectors for monitoring reactor core, fuel pool, and their components. Gamma and Neutron detection use a proportional detector. CP-MU-GN. Four Linear Ranges:
- CP-MU-D1 (Gamma) High Range
- CP-MU-D100 (Gamma) Mid Range
- CP-MU-D1000 (Gamma) Low Range
- CP-MU-7-D1 (Gamma) Very High Range
CP-MU-GN (Gamma and Neutron Proportional Detector). Very High Range. Local readout. Optional: Computer interface.
Click For Portable Ion Chamber Comparison Chart
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High-Range Submersible Monitors. Digital. Portable. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven (Model CP-MU) coupled to specific ion chamber detectors for use monitoring reactor core and fuel pool and their components. Gamma and Neutron detection use a proportional detector. CP-MU-GN High-Range Submersible Monitors. Four Linear Ranges:
- CP-MU-D1 (Gamma) High Range
- CP-MU-D100 Gamma) Mid Range
- CP-MU-D1000 (Gamma) Low Range
- CP-MU-7-D1 (Gamma) Very High Range
CP-MU-GN (Gamma and Neutron Proportional Detector) Very High Range. Local readout. Optional: Computer interface.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multiuse Radiation and Chemical Air Monitor. Digital. Bench Top. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination is available. 1 each for a solid-state detector for Alpha and Beta particulates. Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-REM
Neutron Air System
Neutron Air Monitoring System. Digital. Installed or Rack Mounted. Moderated proportional BF3 neutron tube. Use for tracking the level of Neutron radiation present in and around nuclear reactors, accelerators, neuron sources, and generators, etc. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9W-V
Radiation Control
Radiation Control Monitor. Digital. Bench Top or Installed. Exit/Doorway Monitor - Package/Mail Monitor - Vehicle Monitor -Laundry Monitor. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9W Series
Wide Range Area
Wide Range Area Monitor. Digital. Bench Top or Installed. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wide Range Beta-Gamma GM Area Monitor. Single or Multi-Channel. Digital. Rack or Wall mount. For in and around nuclear reactors, hot cells irradiators, and other facilities handling radioactive materials or x-rays. Local or Remote monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GRAPPLE Scanner
Crane Mounted Scanner
Grapple or Crane Mounted Gamma and Neutron Radiation Detector System. Digital. Portable. Use in scrapyards, containers. Suitable for any grapple or crane. No moving parts, quick change between grapples or crane. Display in Grapple Operator cab. Optional: Wireless remote alarm, readout and data download to base station.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NRF31
Gamma/X-Ray/Neutron
Gamma, X-Ray, Neutron Pocket Dosimeter. Digital. Portable. Dose and dose rate. Compact, lightweight, impact resistant with long battery life. EMF interference resistant. Data download via reader.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NSN3
Neutron Survey
The NSN3 Neutron Survey Meter is designed for Nuclear Reactors, Neutron Sources, and Generators, customs inspections, etc. Portable, lightweight with fast count and zero drift. Measures ambient dose equivalent and ambient dose rate equivalent of neutrons.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Universal Survey Meter. Portable. Digital or Analog. Use with Technical Associates GM, Proportional, Scintillation, Solid-State Probes. Alpha, Beta, Gamma, Neutron, X-Ray. Six decades. Four range survey meters. The readout is in microR/h (or SI units). Three models: PUG-7-D - alarm. PUG-70-D – User Settable Alarm. PUG-7-DF – Full System includes PUG-7-D Electronics with PGS-3 (one inch Nal(TI) scintillator) Gamma Probe. Battery operated. Optional: AC. Local Read Out.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Neutron PUG-Analog. Portable. Detects fast (PNS-19) or slow/fast Neutrons (PNS-20), and favors slow Neutrons. It is lightweight and includes the electronics, moderator, and probe. Battery operated. Local Read Out.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Neutron PUG. Portable. Analog. Detects fast (PNS-19) or slow/fast Neutrons (PNS-20) and favors slow Neutrons. It is lightweight and includes electronics, a moderator, and a probe. Battery operated. Local Read Out.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 3 Mounting Models: Mobile Crane, Truck, both with top-down detection; Fixed Vertical Wall with drive-by detection. Three models: Gamma only RAD-7-CANSCAN. Gamma/Neutron RAD-8-CANSCAN. Gamma/Neutron/Neutron Generator RAD-9-CANSCAN. Multichannel Analyzer (MCA).
The RAD-7, 8, 9 CANSCAN have two main elements: (1) an 8ft tall x 1 ft wide mobile detector column and (2) the computer analysis console. RAD-9 CANSCAN has a third element, a neutron generator requiring a Neutron Generator license to own and operate.
Detects Gamma and Neutron Radiation with (30) 3"x1" Gamma scintillator detectors and (1) 5" Neutron scintillator detector. Fast scan. Creates pinpoint location map of container or truck interior and remote alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-10-CANSCAN
RAD-11-CANSCAN
Container Scan
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 2 Mounting Models: Crane with top-down detection; Fixed Vertical Wall for drive-by detection.
Detects Gamma and Neutrons Radiation with (30) 3"x1" Gamma scintillator detectors and (2) 3" Neutron detectors. Fast scan. Multichannel Analyzer (MCA). Creates pinpoint location map of container or truck interior. Local and remote alarm, readout, and monitoring. Computer interface.
Two models: Gamma/Neutron RAD-10-CANSCAN. Gamma/Neutron/Neutron Generator RAD-11-CANSCAN requires a neutron Generator license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-20-CANSCAN
RAD-21-CANSCAN
Container Scan
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 2 Mounting Models: Two detection styles: Crane with top-down detection; Tunnel Mounted with drive-through detection. Multichannel Analyzer (MCA). Creates pinpoint location map of container or truck interior. Local and remote alarm, readout, and monitoring. Computer interface.
Detects Gamma, Neutrons Radiation with. (30) 3"x1" Gamma scintillator detectors and (1) 7" Neutron scintillator detectors. Fast scan.
Two models: Gamma only RAD-20-CANSCAN. Gamma/Neutron/Neutron Generator RAD-21-CANSCAN requires a Neutron Generator license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-ID-TA
Portable Isotope Identifier
The Portable Isotope Identifier. Digital. Bench Top or Cart Mounted. Multi-Channel Analyzer (MCA). Detect Alpha, Beta, Gamma, Neutron, Positron. Used as both a sample counting system and/or a search tool in addition to monitoring hood, glove box, packages, or other hazardous situations. Use a wide variety of detectors. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RADBACK-GN
Backpack Gamma / Neutron
Backpack Gamma / Neutron. Field ready, with data analysis, data logging. High sensitivity. Lightweight. Rechargeable batteries and AC / DC charger. LED belt unit alert and earphone. Computer interface. Optional: MCA Spectroscopy and isotope identification.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sample Counting Systems. Digital. Portable.
- STG-4: Beta-Gamma Counting Scintillation System.
- STG-4TP: Low Energy Gamma Scintillation System with preamplifier
- STG-4T: Low Energy Gamma Scintillation System.
- STB-3: Beta Gamma GM System.
- STAM-2: Alpha Scintillation System.
- STAM-5N: Neutron
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6GN
Gamma/Neutron Analyzer
Gamma Micro Meter plus Neutron Analyzer. Digital. Portable. Dual readout with Gamma in μ R/hr and Neutrons in cps. Designed specifically for use by inspectors and guards, police and hazmat squad to give warning in case of illicit or accidental storage or transport of radioactive and fissile material. Optional: Telescoping wand. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SP
Dual Detector
Dual Detector Scintillation/Pancake TBM. Analog. Portable. Detects Alpha, Beta, Gamma, Iodine, Tc99m and X-ray. Lightweight system. Internal 2 inch pancake GM detector downward looking window at bottom of case with sliding shield protector. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PTG-9-14
Carbon-14 Air/Stack
Carbon-14 Air/Stack Monitor. Digital. Installed. Continuous. Electronics; Portable or Bench Top. Wide range. Local readout. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SSS-22P Series
Liquid Scintillation
Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Multichannel Analyzer SSS-22-MCA, suitcase version of SSS-22P SSS-22PAL, lab version of SSS-22P SSS-22LAB. Local readout and alarm. Computer interface. Optional: 6 sample adapters.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TOTAL-6
NPP Stack/Effluent
Stack Monitor. Digital. Installed. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium and C-14 with focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. A Commercial version is available for research labs, room air, glove boxes and other applicable uses.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TriCair
Tritium and C-14
Tritium and C-14 Detector. Digital. Portable. Detects Tritium and C-14. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Read out. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HOMELAND SECURITY - NEUTRON
DRONERAD-P
UAV Plume Detector
Plume detector. UAV mounted DroneRAD System. Digital. Portable. Alpha, Beta, Gamma, C-14. Aerial radiation detector DroneRAD software, built-in air pump, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Air Monitor and Plume detection DroneRAD-P. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DRONERAD-ST
UAV Search Tool
Search Tool fixed source-detector. UAV mounted DroneRAD System. Digital. Portable. Gamma, optional Neutron aerial radiation detector, DroneRAD software, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Downward-looking Gamma and optional Fast Neutron spotters for ground, building, vehicle, and facility air surveillance. DroneRAD-ST. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-ID-W
Inspector’s Scanner
Portable Inspector’s Radiation Scanner. Digital. Backpack, Roller Case or Cart Mounted. Detects Neutrons and Gamma Radiation. For use in Airports, Seaports, and anywhere else illegal transportation or use of radiation is suspected.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 3 Mounting Models: Mobile Crane, Truck, both with top-down detection; Fixed Vertical Wall with drive-by detection. Creates pinpoint location map of container or truck interior. Fast scan. Local and remote alarm, readout, and monitoring. Multichannel Analyzer (MCA). Computer interface.
The RAD-7, 8, 9 CANSCAN have two main elements: (1) an 8ft tall x 1 ft wide mobile detector column, (2) the computer analysis console. RAD-9 CANSCAN has a third element a neutron generator requiring a license to own and operate.
- Detects Gamma, Neutron Radiation with (30) 3"x1" Gamma scintillator detectors and (1) 5" Neutron scintillator detector.
- RAD-7-CANSCAN Gamma only. RAD-8-CANSCAN Gamma/Neutron. RAD-9-CANSCAN Gamma/Neutron/Neutron Generator. Generator requires a license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-10-CANSCAN
RAD-11-CANSCAN
Container Scanner/2
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 2 Mounting Models: Crane with top-down detection; Fixed Vertical Wall with drive-by detection. Detects Gamma, Neutrons Radiation with (30) 3"x1" Gamma scintillator detectors and (2) 3" Neutron detectors. Fast scan. Multichannel Analyzer (MCA). Creates pinpoint location map of container or truck interior. Local and remote alarm, readout, and monitoring. Computer interface.
RAD-10-CANSCAN Gamma/Neutron. RAD-11-CANSCAN Gamma/Neutron/Neutron Generator requires a license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-20-CANSCAN
RAD-21-CANSCAN
Container Scanner/3
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 2 Mounting Models: Crane with top-down detection; Tunnel Mounted with drive-through detection. Detects Gamma, Neutrons Radiation with. (30)"x1" Gamma scintillator detectors and (1) 7" Neutron scintillator detectors. Fast scan. Multichannel Analyzer (MCA). Creates pinpoint location map of container or truck interior. Local and remote alarm, readout, and monitoring. Computer interface.
RAD-20-CANSCAN Gamma only. RAD-21-CANSCAN Gamma/Neutron/Neutron Generator. The generator requires a license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MORAD
Mobile Radiation
Mobile Radiation Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SPE
1st Responder’s Emergency Kit
First Responder’s Radiation Detection Emergency Kit. Analog or Digital. Portable. Detects Alpha, Beta, Gamma, X-Ray, and Neutron. Rugged, lightweight system. Internal 2-inch pancake GM detector downward-looking window at bottom of the case with sliding shield protector. Four external probes for detection of Alpha (PAS-8), low energy Gamma (PGS-3T), all Neutrons (PNS-20T), plus the Gamma Search Probe PGS-3L. Local readout. The kit comes in a carrying case.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-6SP-ST
Surface Search Tool
Surface Monitor / Search Tool. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Internal 2 inch pancake GM detector downward looking window at bottom of case with sliding shield protector. External Model PGS-3 1'' x 1'' scintillation probe for use as a Gamma Search Tool and µ R Meter. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMF-TA Series
Installed Vehicle Monitors
Installed Vehicle Monitors. Digital. Installed. Pass between dual scintillation detectors. Local and remote alarm, readout, and monitoring. Computer interface. Optional: Neutron detector. Wireless remote notification – phone, email, text, video recording. 4 models:
- VMF-TA and VMF-TB each have 528"2 scintillation area.
- VMF-TB has higher sensitivity than VMF-TA.
- VMF-4X doubles the sensitivity area.
- VMF-4XO has an overhead detector.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .