Model

Product Image

Description

Department

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Quick Response Plutonium Air Monitor. Electronics; Portable or Bench Top. Sees Alphas and Betas in high or varying background situations. Two different detectors. Stand-alone or networked with other detection locations. Local and remote alarming, readout and monitoring. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

PET, Iodine, Tc-99m DTPA Air Monitor. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Application: Hospitals / Research, Power Plants, National Labs. Local and remote alarming, readout, and monitoring. Data archive/retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Beta / Gamma Particulate Monitor. T-1190 GM detector. Flow rate 70 lpm standard. The filter is under constant surveillance via a thin window GM pancake detector. FM-9-BG-C has a cyclone particle separator. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed, Portable, Bench Top or Cart Mount.

Iodine-125 and Xenon-125 Ratemeter.  Dual Ratemeter. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Local Readout. Data archive/retrieval. Computer interface. Real-time mass flow meter. Use for the stack, hood, glove box, or area air.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top or Installed.

Radiation Control Monitor. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Accommodates over 50 types of detectors.

  • Exit/Doorway Monitor
  • Package/Mail Monitor
  • Vehicle Monitor
  • Laundry Monitor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed, Portable, Bench Top or Cart Mount.

Iodine Monitor Total Airborne Activity. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector. Line operated. Local readout. Data archive/retrieval. Computer interface.

FR-PII-Pb uses a ½" lead shield. Use as an industrial workplace and hospital breathing air measurement system, and monitor fume hoods and stack effluent down to EPA levels.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed, Portable, Bench Top or Cart Mount.

Chromatogram Scanning Counter. AC. The HY-1 is a Medical Isotope System. It is an automatic scanner for TLCs, gels, paper chromatograms, and electrophoreses, to allow immediate visualization and estimation of isotopic content. Includes MCA. Onboard computer and Computer interface for data download.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Benchtop. Digital.

Chromatogram Scanning Counter. AC. The HY-1 is a Medical Isotope System. It is an automatic scanner for TLCs, gels, paper chromatograms, and electrophoreses, to allow immediate visualization and estimation of isotopic content. Accepts 3 detector types: GM, Gas Flow, and Scintillation. Scans 6 traces simultaneously. A moving 10" x 20" table carries two 20cm x 20 cm TLCs or other samples in controlled steps under a bridge, examines traces on the sample, and transfers information to a printer or strip chart recorder. Detectors are interchangeable. Includes MCA. Computer interface for data download.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Radiation Control Monitor - Exit/Doorway Monitor, Package/Mail Monitor, Vehicle Monitor, Laundry Monitor Detects Beta/Gamma. Mount above the sorting table, conveyor belt, or doorway. Electronics: LAM-10-D Ratemeter. Audio visual alarm. Optional: Wireless remote notification – phone, email, text, video recording. Local readout. Computer interface. Two models:

  • PGS-3 1" x 1" scintillation crystal.
  • PGS-3-L 2" x 2" scintillation crystal.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable-Hand Carry, Cart Mounted, Detachable.

High-Capacity Air Monitor. Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, Noble Gas, and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface. Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital, Benchtop, or Installed.

Water monitor for Alpha isotopes: Most Alphas including U-238, Po-210, and Radon. Continuous Real-Time water monitor. Monitor for contamination of in-ground or surface water. Monitor liquid waste stream from hospitals, laboratories or plants, mining/oil/gas extraction, and Nuclear Power plants. Data archive and retrieval. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital, Benchtop, or installed.

Water monitor for Beta isotopes: I-131, Sr-90/Y-90, Sr-89, Cs-137, Cs-134, etc. Continuous Real-Time Monitor drinking water against any and all Beta Emitter Contaminants except H-3, C-14, and S-35 Ø Monitor for contamination in-ground or surface water Monitor liquid waste stream from laboratory or plant.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Bench Top.

Liquid Scintillation Counting System. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Optional: 6 sample adapters. Six models:

  • 1 sample SSS-12P
  • 3 samples of SSS-22P,
  • 3 samples with a Multichannel Analyzer SSS-22-MCA,
  • All-in-one suitcase version: 3 sample systems and electronics - SSS-22PAL
  • SSS-22PAL-ID comes with MCA,
  • SSS-22-LR (Low Range Tritium).

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Installed.

Flow Through Gas Proportional Monitor for Airborne Radiation. A highly sensitive Alpha, Beta, and Gamma flow through the gas counter. It consists of an internal gas proportional detector, mixing chamber, thermostat assembly, and a scaler, timer, and pulse height analyzer. Use as an accessory to a gas chromatograph. AC power. Audio/visual alarm. A user-settable alarm relay to control other devices. Data archive and retrieval. USB and Ethernet. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Portable.

Alpha, Beta-Gamma, and X-Ray Surface Contamination Meter. Surface contamination monitor. Recommended by experts for the fire department and First Responder use. Local readout. Click For GM Pancake Tube Response Report.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Analog. Portable.

Dual Detector Scintillation/Pancake GM. Internal 2-inch pancake GM detector downward looking window at bottom of the case with sliding shield protector detects Alpha, Beta, Gamma, Iodine, Tc99m, and X-ray. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital. Table Top, Rack mounted, or Free Standing.

Tritium-Air. Continuous real-time monitoring. Designed to analyze Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. This system consists of an efficient condenser that pulls Tritiated water vapor from the air. AC power. Data archive and retrieval for up to five years. Computer interface.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .