When Homeland Security is considered, it is almost typically thought of in terms of an active shooter or a bomber. This means the police, SWAT, bomb squad, emergency services such as EMTs, and other responders. Terrorist activity: from dirty bombs in backpacks to radioactive material dumped in reservoirs, depleted uranium bullets, and other tactical ordnance, to radioactive smoke coming out of a burning medical facility or industry. The need to protect First Responders from encountering a radioactive threat is essential. Technical Associates, a division of US Nuclear Corp, has developed an exceptional suite of instruments to provide that security in the evaluation of the threat at hand, prior to initial response.
MODEL
DESCRIPTION
UAV AIR FORENSICS
Technical Associates, a division of US Nuclear Corp, utilizes a variety of UAV flight platforms. The UAV selected is to meet the customer’s mission requirements. The selection regardless of model or manufacturer is Weather resistant to heavy-lift commercial UAVs. Automatic return to home, autonomous waypoint capability, intelligent flight modes, commercial-grade carbon fiber frame, GPS position and hold, Flight telemetry overlay, stable in 20 mph (32 km/h) wind.
- Optional: Sense and Avoid.Payload up to 11 pounds, 6 commercial-grade heavy-lift motors. Flight times up to 70 minutes, dependent on payload weight, speed 35 mph, (56 km/h), FPV camera, and real-time video downlink. USA made. Fly Detectors Together or Separately.
- Optional: Cameras: User-specific. Note: UAV Platform Is Selected To Meet User’s Mission Requirements.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plume detector. UAV mounted DroneRAD System. Digital. Portable. Alpha, Beta, Gamma, C-14. Aerial radiation detector DroneRAD software, built-in air pump, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Air Monitor and Plume detection DroneRAD-P. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fixed source-detector. UAV mounted DroneRAD System. Digital. Portable. Gamma, optional Neutron aerial radiation detector, DroneRAD software, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Downward looking Gamma and optional Fast Neutron spotters for ground, building, vehicle and facility air surveillance. DroneRAD-ST. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UAV Mounted Chemical Detector. Digital. Portable. Detects a wide variety of airborne chemicals. List available on Data Sheet. Wireless radio download to the ground station. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DroneCHEM-LMC-TA
Laser Methane Detection
UAV Mounted Chemical Detector. Digital. Portable. Laser detects airborne methane. Real-time wireless data download transmission to the included ground station. Easy Installation. Fast deployment. Immediate results. Wireless data download. Display map. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DroneCHEM-908
CWA Chemical Detection
(Data sheet coming soon)
UAV Mounted Chemical Detector. DroneCHEM-908 Digital. Portable. Detects airborne CWAs. Mass spectrometry delivers enhanced sensitivity and broader threat category coverage. Unmatched flexibility and trace detection power for elite responders in chemical, explosive, and priority hazmat scenarios. Audio/visual alarms. Chemical identification. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This two-detector system provides an overview of any methane leaks and close-up leak detection and quantitative measurement and source location with real-time wireless download to the ground station, laptop, or other data acquisition system. Keep workers out of harm’s way. Detection is GPS tagged.
- The DroneCHEM-LMC-TA is an optical laser detection, lightweight unit for methane and can be up to 82 feet away, depending on plume size and methane ppm.
- The DroneCHEM-AERO-MS is a flow-through air sensor with a built-in flow-through fan for the detection of methane. This lightweight UAV-based unit can fly along pipelines or in areas of potential methane leaks.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WATER: SUBMERSIBLE ROBOT SUBMARINE SURVEILLANCE
Full Kit- Submarine Robot Kit
Underwater Explorer Submarine. Portable. Includes submersible, video, and base station electronics. Tethered data stream and onboard data storage serial port. 100 feet depth
- DiveRAD-ST and DiveRAD-P Full Kit.
- DiveRAD-ST Search tool detects Gamma with Optional Neutron Detector.
- DiveRAD-P Plume detector for Alpha, Beta, Gamma Radiation particulates. Detects Chemical and Biological Contamination.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WATER
Tritium in Water Monitor. Digital. Benchtop. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Check Water Monitor. Digital. Portable. Two detectors Internal-t-1190 Alpha, Beta, Gamma detector with a sliding Beta shield. External-submersible Gamma detector. Local readout. Other scales and overlays available: Sieverts, etc. Use anywhere. Great for First Responders. Ranges: 4 linear for each detector:
- 0-500; 5,000; 50,000; 500,000 cpm for external.
- 0-0.15; 1.5; 15; 150 mR/hr. for internal detector.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Water Test/Treat System. Digital. Portable or Installed. Alpha, Beta, Gamma detection. BioSensor for Oxidation Reduction Potential (ORP) and Total Organic Carbon (TOC). Test and Treatment for radioactive and biological contamination.
Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring and treatment of drinking water 24/7. Facilities with multiple water inlets may wish to install multiple NEX-ABG-9TTs. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drinking-Water and Waste Water Monitor. Digital. Rack Mounted or Wheeled Base. Continuous. Detects Gamma. Monitor ground, surface water, and industrial liquid-waste-stream. Useful in complying with discharge requirements for wastewater. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.
- Optional: Detectors: Alpha, Beta, Tritium, Radon.
- Optional: Submersible Gamma probe
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sea Water Monitor Continuous Real-Time. Digital. Installed. Continuous. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.
- Optional: Ozone System.
- Optional: Tritium detection.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drinking-Water Monitor. Continuous Real-Time. Digital. Installed. Continuous. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. FAQ
- Optional: Ozone System.
- Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water).
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Strap-On Water Pipe Monitor. Portable. Gamma detection of waterborne radioactivity with NaI (Tl) crystal scintillation detector. Detection of contamination flowing thru one or more pipes. Battery operated. A constant check with real-time alarm. Measurement independent of water flow rate. Quick set-up with no penetration, no downtime. Electronics: Model TBM-3D with Optional: computer interface, data archive and retrieval, integration into facility computer and linking to multiple detectors for portable system.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radon in Water. Analog. Portable. Radon Alpha Scintillation system and combines a modified PAS-8 Alpha Scintillation Probe plus FLO-9 water-flow-thru sampler. Monitor aquifer for rising Radon levels in complying with EPA and Water Districts standards. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Raw Water Monitor. Continuous Real-Time. Digital. Portable or Installed. Continuous. Detects Gamma. Single detector RAWA-GP. Dual detector RAWA-BGP for Beta and Gamma. Sensitivity: See Data Sheet Chart. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Useful in complying with discharge requirements for wastewater. Modular system allows function changes or additions and rapid repair in the field.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radon Water Monitor. Digital. Bench Top or Rack Mounted. Real-Time Continuous. Monitor laboratory or plant liquid waste stream. Sensitivity: to 200 pCurie/liter. Not influenced by other nuclides. Local readout. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Integrated Chemical, Biological, and Radiation Water Robust Monitoring System. Continuous Real-Time. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIR
Networkable or Standalone Air Monitor. Digital. Portable or Installed. Detects Alpha, Beta Particulates, Ambient Gamma. 1 or 2 channel options. (1) channel ABG-NET. (1) second channel for Radon ABG-R-NET. Moving filter head. Internal data logger. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. Typically used in conjunction with FM-9HUB Electronics.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AIR-TBM
Multi-Use Monitors
Alpha, Beta, Gamma Air Monitor. Wipe Counter / Survey Monitor. Digital. Portable. TBM-3SR-D electronics with built-in T-1190 GM Pancake Detector. Local Readout. Computer interface. Perfect for First Responders, Hospitals, Clean Up sites, Pharmacies, etc. Battery or AC powered. Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Networked Radiation Tracking System. Digital. Portable or Installed. Can network with existing surveillance systems. Detects Gamma and Neutron. Gamma - NaI (or BGO) Scintillation detector. Neutron - BF3 Proportional Probe. Easy placement of detectors and integration into existing systems. Sensitive, wide range. Remote access and wireless notification are available. Computer interface with RS-232 or ethernet data collection. Alarm user settable.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Computing engine for multiple instruments and systems. Wall mount, digital.
- Powers channels for multiple instruments: air, water, area, vehicle, and personnel.
- Continuous, real-time, rugged duty.
- Includes computer and color monitor.
- Easy integration to facility mainframe if desired.
- Single channel to 20 channels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Quick Response Plutonium Air Monitor. Digital. Portable. Electronics; (2) Options: Portable or Bench Top. Sees Alphas and Betas in high or varying background situations. Two different detectors. Local and remote alarming, readout and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High-Capacity Air Monitor. Digital. Portable-Hand Carry, Cart Mounted, detachable. Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, and Noble Gas and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tritium Air Survey Monitor. Digital. Portable, Light weight. Built in air pump 2-3 lpm. Basic Sensitivity of the order of 10 µCi/m3. Dual Ion Chambers. Electronics. Wide range. Local readout. Computer interface RS232.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mobile Radiation Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable Personnel and Package Monitors. Freestanding or installed in a wall or doorway. Can be used for people or anything else which passes by the scintillation detector. Perfect for Covert Scanning in a Crowd. Suitcase or roller case. The vibration alarm is felt on the handle and the visual alarm light is on the handle.
- Optional: Video – Real-Time Display and Capture
- Optional: Wireless Remote Notification – Phone, Email, Text, etc.
The QUICKSCAN-PPM Series uses plastic scintillators. QUICKSCAN-PPM-L one detector 126 in3 in a hand-carry suitcase. QUICKSCAN-PPM-F two detectors equals 296 in3 in a roller case. Completely weatherproof. Continuous operation 'set and forget'. Local alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable Personnel and Package Monitors. Freestanding or installed in a wall or doorway. Can be used for people or anything else which passes by the scintillation detector. Perfect for Covert Scanning in a Crowd. Suitcase or roller case. The vibration alarm is felt on the handle and the visual alarm light is on the handle.
- Optional: Video – Real-Time Display and Capture
- Optional: Wireless Remote Notification – Phone, Email, Text, etc.
The QUICKSCAN-PPM Series uses plastic scintillators. QUICKSCAN-PPM-L one detector, 126 in3, in a hand-carry suitcase. QUICKSCAN-PPM-F two detectors equal 296 in3 in a roller case. Completely weatherproof. Continuous operation 'set and forget'. Local alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radon 220 and 222 Monitor. Digital. Portable, Continuous. Electronics. Highly sensitive and rugged. Fast detection 10 minutes – 30 minutes depending on sensitivity required. Gamma rejection. Range: 0.1 – 2000 pCi/l. User settable units. Ideal for inspectors. Simple stand-alone radon detector providing real-time measurement over a wide range of concentrations. All data is stored. Local readout. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alpha, Beta-Gamma, and X-Ray Surface Contamination Meter. Digital. Surface contamination monitor. Built-in 2” diameter pancake tube with sliding Beta shield and speaker. 0.01 to 100.00 mR/hr. Recommended by experts for the fire department and First Responder use. Local readout. Optional: RS232 Serial Port.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
First Responder’s Radiation Detection Emergency Kit. Optional: (2) models: Analog or Digital. Portable. Detects Alpha, Beta, Gamma, X-Ray & Neutron. Rugged, lightweight system. Internal 2" pancake GM detector downward-looking window at bottom of the case with sliding shield protector. Four external probes for detection of Alpha (PAS-8), low energy Gamma (PGS-3T), all Neutrons (PNS-20T), plus the Gamma Search Probe (PGS-3L). Ranges 4 linear for each detector:
- External Detector: 0-500; 5,000; 50,000; 500,000 cpm.
- Internal Detector: 0-0.15; 1.5; 15; 150 mR/hr.
The kit comes in a carrying case. Local readout. Optional: Alarm – Audio / Visual, USB or RS-232 Ports
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surface Monitor / Search Tool. Analog. Portable. Detects Alpha, Beta, Gamma, and X-Ray. Internal 2-inch pancake GM detector downward-looking window at bottom of the case with sliding shield protector. External Model PGS-3 1'' x 1'' scintillation probe for use as a Gamma Search Tool and µ R Meter. 4 linear ranges for each detector:
- External: 0-500; 5,000; 50,000; 500,000 cpm.
- Internal: 0-0.15; 1.5; 15; 150 mR/hr. Local readout.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TBM-IC-HLS
Wide Range Ion Chamber
Wide Range Ion Chamber. Digital. Portable. Alpha, Beta, Gamma, X-Ray. Detects X-Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. Local readout. This very wide range conforms to ANSI N42.33 Homeland Security Type 2.
Click For Portable Ion Chamber Comparison Chart.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real-time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Readout. Computer interface. TriCair-Select provides User selection of Organic-C14 or In-Organic C-14 - 1-19,999 µCi/m3, with Basic Sensitivity: 1 µCi/m3.
- Tritium Range for A, B and Select: 1-19,999 uCi/m3. Basic Sensitivity: 5 µCi/m3
- TriCair-A for Inorganic-C14 - 1-19,999 µCi/m3. Basic Sensitivity: 1 µCi/m3
- TriCair-B for Organic-C14 - 1-19,999 µCi/m3. Basic Sensitivity: 1 µCi/m3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tritium-Air. Digital. Table Top, Rack mounted, or Free Standing. Continuous real-time monitoring. Designed to analyze Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. This system consists of an efficient condenser that pulls Tritiated water vapor from the air. AC power. Data archive and retrieval for up to five years. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNITECT-AIR
Integrated Air Monitor
Integrated Air Monitor: Radiation, Chemical, Biological. Digital. Installed. Robust, Continuous Real-Time. Monitoring System. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PORTAL AND CARGO
Personnel, Vehicle, Waste/Trash Portal Monitors. Digital. Portable or Installed. Two towers each with scintillation detectors. Weather-proof. Continuous operation ‘set and forget’. (5) Model options.
- PPVM-TA Total (2) scintillation detectors. (2) Towers. Portable or Installed, Walls, or Doorways. Freestanding, Fences,
- PPVM-TA-P Total (2) scintillation detectors. (2) Towers. Portable: Freestanding, Fences, Walls, or Doorways
- PPVM-TA-3: Total (7) scintillation detectors.(2) Towers. (1) overhead detector. Has a Higher sensitivity than PPVM-TA.
- PPVM-TA-5ES: Total (11) scintillation detectors.(2) Towers. (1) The overhead detector is designed for indoor use, hallways, and doorways.
- PPVM-TA-1: Total (1) scintillation detector.(1) Tower.
Optional: Underfoot detector. Handheld Alpha/Beta Detector. Installed Neutron detector
Optional: Local and remote alarm, readout, and monitoring. Computer interface.
Optional: Wireless remote notification – phone, email, text, video recording.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Backpack Gamma / Neutron. Field ready, with data analysis, data logging. High sensitivity. Lightweight. Rechargeable batteries and AC / DC charger. LED belt unit alert and earphone. Computer interface. Optional:MCA Spectroscopy and isotope identification.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radiation and Metal Wand. Portable, lightweight. Merging existing technology for metal scanning with radiation detector into an easy-to-use lightweight handheld wand provides security officers with a robust multi-use instrument. With 2 different LED indicators and 2 different alarm tones to notify the operator which type of threat is alarming.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 3 Mounting Models: Mobile Crane, Truck, both with top-down detection; Fixed Vertical Wall with drive-by detection. Three models: Gamma only RAD-7-CANSCAN. Gamma/Neutron RAD-8-CANSCAN. Gamma/Neutron/Neutron Generator RAD-9-CANSCAN. Multichannel Analyzer (MCA).
The RAD-7, 8, 9 CANSCAN have two main elements: (1) an 8ft tall x 1 ft wide mobile detector column and (2) the computer analysis console. RAD-9 CANSCAN has a third element, a neutron generator requiring a Neutron Generator license to own and operate.
Detects Gamma and Neutron Radiation with (30) 3"x1" Gamma scintillator detectors and (1) 5" Neutron scintillator detector. Fast scan. Creates pinpoint location map of container or truck interior and remote alarm, readout, and monitoring. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-10-CANSCAN
RAD-11-CANSCAN
Container Scan
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 2 Mounting Models: Crane with top-down detection; Fixed Vertical Wall for drive-by detection.
Detects Gamma and Neutrons Radiation with (30) 3"x1" Gamma scintillator detectors and (2) 3" Neutron detectors. Fast scan. Multichannel Analyzer (MCA). Creates pinpoint location map of container or truck interior. Local and remote alarm, readout, and monitoring. Computer interface.
Two models: Gamma/Neutron RAD-10-CANSCAN. Gamma/Neutron/Neutron Generator RAD-11-CANSCAN requires a neutron Generator license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAD-20-CANSCAN
RAD-21-CANSCAN
Container Scan
Radiation Scanner for Cargo Containers and Trucks. Digital. Transportable. 2 Mounting Models: Two detection styles: Crane with top-down detection; Tunnel Mounted with drive-through detection. Multichannel Analyzer (MCA). Creates pinpoint location map of container or truck interior. Local and remote alarm, readout, and monitoring. Computer interface.
Detects Gamma, Neutrons Radiation with. (30) 3"x1" Gamma scintillator detectors and (1) 7" Neutron scintillator detectors. Fast scan.
Two models: Gamma only RAD-20-CANSCAN. Gamma/Neutron/Neutron Generator RAD-21-CANSCAN requires a Neutron Generator license to own and operate.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMF-TA Series
Installed Vehicle Monitors
Installed Vehicle Monitors. Digital. Installed. Pass between dual scintillation detectors. Local and remote alarm, readout, and monitoring. Computer interface. Optional: Neutron detector. Wireless remote notification – phone, email, text, video recording. 4 models:
- VMF-TA and VMF-TB each have 528"2 scintillation area.
- VMF-TB has higher sensitivity than VMF-TA.
- VMF-4X doubles the sensitivity area.
- VMF-4XO has an overhead detector.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .