MODEL
DESCRIPTION
PORTABLE & BENCH TOP AIR MONITORS
FM-9-AB2
FM-9-AB2-Be
Alpha/Beta/Gamma/Beryllium Air
Alpha/Beta/Gamma/Beryllium Air Monitor. Digital. Portable or Bench Top. Continuous. Computer interface.
- FM-9-AB2 dual detectors (1) GM Pancake. (1) Scintillator.
- FM-9-AB2-Be added Beryllium filters. Flow rate 70 lpm standard, user-settable. Local Readout. Data archive/retrieval.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-IXE
Iodine-125/Xenon-125 Ratemeter
Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Use for the stack, hood, glove box, or area air. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9XE
Xenon-133 Monitor
Xenon-133 Gas Monitor. Digital. Installed. Continuous. Flow rate 10 lpm standard. Local readout. Pre-filter removes particulates. Local Readout. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MABC
Radiation and Chemical Monitor
Multiuse Radiation and Chemical Air Monitor. Digital. Bench Top. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination is available. 1 each for a solid-state detector for Alpha and Beta particulates.
Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MA2 Series
Alpha, Beta Particulate, Thoron & Radon
Thoron and Radon Gas Air Monitors. Alpha, Beta Particulate. FM-9-MA2 Series: Digital, Portable, Installed. Real-Time operation. Local or Remote Sampling and Read Out. Data archive/retrieval. Computer interface.
- FM-9-MA2 - Alpha Only
- FM-9-MAB2 - Alpha and Beta
- FM-9-MAB2-M - Mobile. Moving filter head for FM-9-MAB2-M only.
- FM-9-MA2-T - Gas Ion Chamber is added to the Alpha and Beta detector system.
- FM-9-MA2-R Radon - Gas Ion Chamber is added to the Alpha and Beta detector system.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MCA
PET/Iodine/Tc-99m
PET, Iodine, or Tc-99m DTPA Air Monitor. Digital. Bench Top. Multi-Channel Analyzer (MCA). Continuous. Monitor air room or stack effluent. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-MCA-2
Iodine-125/Gas/Particulate
Iodine-125 Air Gas and Particulate Air Monitor. Digital. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Computer interface. Flow rate 70 lpm standard.
Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9-M2
Beta Particulate System
Beta Particulate Air Monitor System. Digital. Bench Top. Continuous. 2 GM detector system. (1) Beta Particulates, (1) for Dynamic Background Subtract. Integrated exposure. Local and remote continuous real-time sampling. Quick change filter. Electronic Mass Flowmeter. Data archive/retrieval. Computer interface.
Expandable system with FM-9 series modules.
Click For GM Pancake Tube Response Report.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9W-V
Radiation Control
Radiation Control Monitor. Digital. Bench Top or Installed.
- Exit/Doorway Monitor
- Package/Mail Monitor
- Vehicle Monitor
- Laundry Monitor
Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FM-9NGAS Series
Noble Gas Monitor
Noble Gas, Argon, Xenon, Krypton Monitor. Digital. Installed, Cart Mounted, or Benchtop.Real-time, continuous, digital display. Five models to choose from including the cart-mounted FM-9XE-NGL Leak Detector an the 10 scintillation detector model FM-9NGAS-10S. Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Portable Radon Monitor Systems. Used to determine the radon content of the air in basements, mills, mines, buildings, or anywhere radon concentration is a concern.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 347 is digital and a highly sensitive tritium air monitor that includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 357 is a digital, general-purpose Tritium in air monitor with dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarm. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TriCair-A, B SELECT
Tritium and C-14
Tritium & C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Read out. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VAP-X-Radon
VADO-Zone/Soil
VADO-Zone/Soil Air System. Digital. Portable. Detects Radon. Vapor extraction from soil facilitates:
Pin-point leak source & location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Radon vapor in soil process.
Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VAP-X-Tritium
VADO-Zone/Soil
VADO-Zone/Soil Air System. Digital. Portable. Detects Tritium. Vapor extraction from soil facilitates:
Pin-point leak source & location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process.
Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .