Searching for "VAP-X-Tritium"

Number of results 6

  • VAP-X-Tritium

    VAP-X-Tritium

    Technical Associates VAP-X-Radon Monitor is a sensitive, rugged, portable instrument for detection and measurement of Radon vapor in the soil. Its subtractive balanced chamber electrometer circuit decreases background effects to negligible levels and its deionized and filtered intake reduces to negligible levels spurious effects from dust and existing ionization in soil air. It is battery or AC operated.

    Inlet and outlet hoses are provided. The VAP-X-Radon will measure airborne Radon in any form: water vapor, hydrogen gas or as volatile chemicals in concentrations as low as 1 x 10-5 uCi/cc of air. (370 KBq/m3)

    Data Sheet Page One

    Data Sheet Page Two

    Complete Data Sheet

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Tritium

    MODEL

    DESCRIPTION

    TRITIUM, AIR

    CAM-33 Series
    Air/Stack Monitors

    Multi-Channel Air Monitor. Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Optional: Alpha, Tritium, and Carbon-14 detection are available. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. A Commercial version is available for research labs, room air, glove boxes, and other applicable uses. Click here for screenshots

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FPT (H3) Series
    Fuel Pool Tool

    Fuel Pool Tool. Digital. Installed. Detects Tritium in NPP pool water, pool room air condensation. Monitors pool water temperature FPT-H3. Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Air and Stack Monitor. Digital. Installed. Continuous Real-Time. Ultra-sensitivity to low-level Tritium (at or Below Public Release Levels). Dose-rate and Dose. Can be located remotely. Archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 200SB is a Tritium survey monitor. Portable. Digital. No zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO-discriminating version. Local display.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 347. Digital. Highly sensitive tritium air monitor that includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 357 Tritium in air monitor. Digital. Portable. General-Purpose. Dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarms. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium in air monitor. Digital. Portable. Gamma compensated. High sensitivity and stability Rapid response. Four 200cc ion chambers: Two ion chambers are used for measurement (400cc total) and two for gamma compensation (400cc total). NiMH rechargeable batteries. Optional: AC adapter. RS232 Data output. CE Marked.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MoRAD

     

    Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PTG-9
    Tritium Air Monitor

    Tritium Air Monitor. Digital. Portable. Wide range. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, a mass flow controller, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair
    Tritium and C-14

    Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real-time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriMaran-Air and Stack
    Ultra Low-Level Tritium

    Ultra Low-Level Automated Tritium Air and Stack Monitor. Digital. Installed. Continuous. Designed for near real-time ultra-low level Tritium detection in Nuclear Power Plants using sample enrichment and proportional counting. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Triathalon Series
    Tritium Ultra Low Air

    Triathalon Tritium Ultra Low Range Monitor. Digital. Installed or Rack Mounted. Continuous. Sensitive, rugged stack, or effluent. Designed for Nuclear Power Plants. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface. The commercial version available for research labs, room air, glove boxes, and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TOTAL-6
    NPP Stack/Effluent

    NPP Stack/Effluent Monitor. Digital. Installed. Continuous. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium and C-14 with focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface. A Commercial version is available for research labs, room air, glove boxes and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    The TRI-DECON is a high efficiency Tritium decontamination system. Convenient with ease of use this miniature Tritium Gas Removal Facility provides a rugged system for harsh environments, is in-line operated provides inlet and outlet hoses for decontamination of fume hood, exhaust stack, etc interiors. Powered by Rechargeable battery with built in charger.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    STG-4S/D and STG-5ATL
    Tritium Monitor

    Tritium Monitor. Continuous Real-Time. Digital. Installed. Continuous. Public release level, sensitive, rugged stack, or effluent monitors. The STG-5ATL will measure airborne Tritium as HTO. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    H3-PLR Series
    Tritium Monitor

    Tritium Monitor. Continuous Real-Time. Digital. Installed. Continuous. Public release level, sensitive, rugged stack, or effluent monitors. H3-PLR-5 – 5 decade. H3-PLR-7 – 7 decade.  Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TASC
    Tritium/C-14 Sampling

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pump, mass flow controller, and regulated oxidizer. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    • UNITECT-AIR combines several detection goals into a single monitor.
    • The UNITECT-AIR continuously monitors Radionuclides using a particulate filter and charcoal filter.
    • Both Industrial and Warfare Chemicals, as well as Biological Threats including Bacteria, Yeast, viruses, and Mold, are monitored with detectors integrated within the UNITECT-AIR system.
    • Additional monitoring is available and will be tailored to specific needs upon request
    • Measurements are logged 24 hr/day - 7 days/week, with alarm capability and a universal read-out adaptable to mainframe infrastructure computers.
    • Local and remote readout and alarm.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Tritium
    Vapor Extraction/Soil
    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates Pin-point leak source/location. Map underground plume. Locate edge of the plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    WATER

    Fuel Pool Tool. Continuous Real-Time monitor. NRC rules require close real-time monitoring of fuel pool status and parameters. For the first time in a Continuous Real-Time monitor TA's FPT-H3 solves this problem by continuously monitoring water and air using Tritium detectors. FPT-H3-ABG incorporates Alpha, Beta, and Gamma detectors for water.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium in Water Monitor. Digital. Benchtop. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra-Sensitive Tritium in Water Monitor. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water fully automated, real-time, continuous. Integrated computer with custom software and large LCD display. Monitors water below EPA drinking water standard of 20,000 pCi/l.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Molten Salt Thorium Reactor Water Monitor. Real-time Continuous. Digital. Installed. Detects Thorium, Tritium, Alpha, Beta and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Nuclear Power Water Monitor. Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Water Monitor. Continuous Real-Time. Digital. Portable or Installed. Detects Alpha, Beta, Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface. (3) Models:

    • (1) Portable with User’s electronics
    • (1) Installed with embedded processor
    • (1) Portable with embedded processor

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking/Waste Water Monitor. Digital. In-Line or transportable (Rack Mounted or Wheeled Base). Continuous Real-Time. Detects Gamma. Monitor ground, surface water, industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TI) OR HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Use NEXGAMMA-2-SEA in Salt Water / Harsh Environments. Five models from which to choose. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    • Optional: Detectors: Alpha, Beta, Tritium, Radon
    • Optional: Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    • Optional: Ozone System.
    • Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking-Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the RAWA-GP option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. FAQ

    • Optional: Ozone System.
    • Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water).

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Water Monitor. Digital. Bench Top or Rack mounted. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Meets EPA drinking water levels.

    • Monitor Leaks in Candu Type Reactors
    • Monitor Tritium Contamination in Ground Water.
    • Monitor Laboratory or Plant Liquid Waste Stream.

    Strategy for Measurement of Tritium in Water / Oil Mixture

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Digital. Bench Top. Military level water test for potable water. Accurately quantitatively measures Carbon-14, Tritium, and most other radioactive materials. measures the low level of Tritium even below 20,000 pCi/l, Clean Drinking Water Levels. meets New Requirements for Military Drinking Water TB MED 577/ NAVMED P-5010/AFMAN 48-138_IP May 2010.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Detects all Alpha/Beta Emitters and Low Energy Gamma Emitters–Including-Tritium, Carbon-14, and Sulphur-35 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Multichannel Analyzer SSS-22-MCA, suitcase version of SSS-22P SSS-22PAL, lab version of SSS-22P SSS-22LAB.  Local readout and alarm. Computer interface. Optional: 6 sample adapter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Down Hole Tritium in Water Detector. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels. Protective ActionGuideline (PAG) / Military Drinking Water limits.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Radon and Tritium Deionizer and Filter. Is a two-stage deionizer producing water equivalent to -distilled water. SSS-33M8-D are the deionizer cartridges. SSS-33M8-F is the Filter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra Low-Level Automated Tritium Water Monitor. Continuous. Designed for near real-time ultra-low level Tritium Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Integrated Chemical, Biological and Radiation Water Robust, Continuous Real-Time. Monitoring System. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Continuous real-time monitoring. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration

    SURVEY, SURFACE, WIPE TEST

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CURIE-H3-PLO
    Wipe Test

    Low Range Tritium Wipe Test Counter. Portable. Measure down to 500DPM. 3" Sample drawer. The unique ion chamber sample counter provides low range Tritium measurement and eliminates the need for a pressurized gas supply or LSA cocktail. USB Output. User-specified engineering units.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    High Range Tritium Wipe Test Counter. An Ion Chamber Sample Counter with FM-9 Smart Electronics. Designed for low energy, HIGH activity counting. Ideal for fusion research or in Tritium production and use. Choice of 5 decades or Optional 8 decades. No LSC or pressurized gas requirement equals no Waste. Computer Interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FF-27
    Tritium Surface

    Tritium and C-14 Surface Contamination Meter. Digital. Portable Gas flow proportional detector. Use for flat surfaces. 100cm2 sensitive area. Local readout. Optional: probe for hands, clothing, and equipment.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium survey monitor. Portable. Digital. No zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO discriminating version. Local display.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    STB-TF-6
    Tritium Wipe Test

    Tritium Wipe Test Counter. Digital. Portable. Detects Tritium, Carbon-14, Sulfur-35, etc. Gas flow proportional detector. Electronics PRS-7. Three single-channel analyzer windows. AC or rechargeable battery power. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Portable Tritium monitor. Based on our popular Model 400 platform and is a small, high sensitivity, handheld, battery (rechargeable) operated, fully Gamma-compensated survey meter with RS232 serial data output and user recalibration features.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VADO-ZONE

    VAP-X-Tritium
    VADO-Zone/Soil System

    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates Pin-point leak source/location. Map underground plume. Locate the edge of the plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Tritium, Air Monitor

    MODEL

    DESCRIPTION

    CAM-33 Series
    Air/Stack Monitors

    Multi-Channel Air Monitor Continuous Real-Time. Digital. Installed. Continuous. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Optional: Alpha, Tritium, and Carbon-14 detection are available. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. A Commercial version is available for research labs, room air, glove boxes, and other applicable uses.
    Click here for screenshots

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FPT (H3) Series
    Fuel Pool Tool

    Fuel Pool Tool. Digital. Installed. Detects Tritium in NPP pool water, and pool room air condensation. Monitors pool water temperature FPT-H3. Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    H3-PLR Series
    Tritium Monitor

    Tritium Monitor. Continuous Real-Time. Digital. Installed. Public release level, sensitive, rugged stack, or effluent monitors. H3-PLR-5 – 5 decade. H3-PLR-7 – 7 decade. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 200SB is a portable, digital Tritium survey monitor with no zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO discriminating version.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 347. Digital. Highly sensitive tritium air monitor that includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 357 Tritium in air monitor. Digital. Portable.General-Purpose. Dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarms. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, and wire-grid chambers to reduce.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PTG-9
    Tritium Air Monitor

    Tritium Air Monitor. Digital. Portable. Wide range. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    STG-4S/D & STG-5ATL
    Tritium Monitor

    Tritium Monitor.Continuous Real-Time. Digital. Installed. Continuous. Public release level, sensitive, rugged stack, or effluent monitors. The STG-5ATL will measure airborne Tritium as HTO. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Slip in a self-contained modular unit for a van or truck for mobile radiation detection. Digital. Installed. Choose up to 7 different detectors for simultaneous detection. Detects Beta-Gamma, and Neutrons. Optional: Targeted OMNI directional detector. Built-in GPS. Includes air and water sampling, MCA, electronics – computer hub – FM-9HUB. Local alarm, readout, and monitoring. Easy to use with Ethernet capabilities. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, a mass flow controller, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair
    Tritium and C-14

    Tritium and C-14 Detector.Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real-time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TRIMARAN-AIR and STACK
    Ultra-Low Level Tritium Air

    Ultra Low-Level Automated Tritium Air and Stack Monitor. Digital. Installed. Continuous. Designed for near real-time ultra-low level Tritium detection in Nuclear Power Plants using sample enrichment and proportional counting. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Triathalon Series
    Tritium Ultra Low Air

    Ultra Low Range Tritium Monitor. Digital. Installed or Rack Mounted. Highly sensitive, Tritium and C-14, real-time continuous. rugged stack or effluent monitor. Designed for Nuclear Power Plants. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface. The commercial version is available for research labs, room air, glove boxes, and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TOTAL-6
    NPP Stack/Effluent

    NPP Stack/Effluent Monitor. Digital. Installed. Continuous. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium and C-14 with focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface. A Commercial version is available for research labs, room air, glove boxes and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Decontamination System. Digital. Installed. This miniature Tritium Gas Removal system has high efficiency with convenience and ease of use. It provides a rugged system for harsh environments. Two electronics options: Model 357: to 1.0 µCi/m3 and Model 347: to 0.5 µCi/m3.  Inlet and outlet hoses provide easy decontamination of fume hood, exhaust stack, etc interiors. Powered by a Rechargeable battery with a built-in charger. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TASC
    Tritium/C-14 Sampling

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pump, mass flow controller, and regulated oxidizer. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Integrated Air Monitor: Radiation, Chemical, Biological. Digital. Installed. Robust, Continuous Real-Time. Monitoring System. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Tritium
    Vapor Extraction/Soil
    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates Pin-point leak source/location. Map underground plume. Locate edge of the plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Portable and Benchtop Monitors

    MODEL

    DESCRIPTION

    PORTABLE & BENCH TOP AIR MONITORS

    FM-9-AB2
    FM-9-AB2-Be
    Alpha/Beta/Gamma/Beryllium Air

    Alpha/Beta/Gamma/Beryllium Air Monitor. Digital. Portable or Bench Top. Continuous. Computer interface.

    • FM-9-AB2 dual detectors (1) GM Pancake. (1) Scintillator.
    • FM-9-AB2-Be added Beryllium filters. Flow rate 70 lpm standard, user-settable. Local Readout. Data archive/retrieval.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-IXE
    Iodine-125/Xenon-125 Ratemeter

    Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Use for the stack, hood, glove box, or area air. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9XE
    Xenon-133 Monitor

    Xenon-133 Gas Monitor. Digital. Installed. Continuous. Flow rate 10 lpm standard. Local readout. Pre-filter removes particulates. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MABC
    Radiation and Chemical Monitor

    Multiuse Radiation and Chemical Air Monitor. Digital. Bench Top. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination is available. 1 each for a solid-state detector for Alpha and Beta particulates.

    Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.
    Click For GM Pancake Tube Response Report.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MA2 Series
    Alpha, Beta Particulate, Thoron & Radon

    Thoron and Radon Gas Air Monitors. Alpha, Beta Particulate. FM-9-MA2 Series: Digital, Portable, Installed. Real-Time operation. Local or Remote Sampling and Read Out. Data archive/retrieval. Computer interface.

    • FM-9-MA2 - Alpha Only
    • FM-9-MAB2 - Alpha and Beta
    • FM-9-MAB2-M - Mobile. Moving filter head for FM-9-MAB2-M only.
    • FM-9-MA2-T - Gas Ion Chamber is added to the Alpha and Beta detector system.
    • FM-9-MA2-R Radon - Gas Ion Chamber is added to the Alpha and Beta detector system.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MCA
    PET/Iodine/Tc-99m

    PET, Iodine, or Tc-99m DTPA Air Monitor. Digital. Bench Top. Multi-Channel Analyzer (MCA). Continuous. Monitor air room or stack effluent. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MCA-2
    Iodine-125/Gas/Particulate

    Iodine-125 Air Gas and Particulate Air Monitor. Digital. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Computer interface. Flow rate 70 lpm standard.

    Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-M2
    Beta Particulate System

    Beta Particulate Air Monitor System. Digital. Bench Top. Continuous. 2 GM detector system. (1) Beta Particulates, (1) for Dynamic Background Subtract. Integrated exposure. Local and remote continuous real-time sampling. Quick change filter. Electronic Mass Flowmeter. Data archive/retrieval. Computer interface.

    Expandable system with FM-9 series modules.
    Click For GM Pancake Tube Response Report.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9W-V
    Radiation Control

    Radiation Control Monitor. Digital. Bench Top or Installed.

    • Exit/Doorway Monitor
    • Package/Mail Monitor
    • Vehicle Monitor
    • Laundry Monitor

    Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9NGAS Series
    Noble Gas Monitor

    Noble Gas, Argon, Xenon, Krypton Monitor. Digital. Installed, Cart Mounted, or Benchtop.Real-time, continuous, digital display. Five models to choose from including the cart-mounted FM-9XE-NGL Leak Detector an the 10 scintillation detector model FM-9NGAS-10S. Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Portable Radon Monitor Systems. Used to determine the radon content of the air in basements, mills, mines, buildings, or anywhere radon concentration is a concern.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 347 is digital and a highly sensitive tritium air monitor that includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 357 is a digital, general-purpose Tritium in air monitor with dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarm. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 400AC is a digital, portable Tritium in air monitor. Gamma compensated. High sensitivity and stability Rapid response. Four 200cc ion chambers: Two ion chambers are used for measurement (400cc total) and two for gamma compensation (400cc total). NiMH rechargeable batteries. Optional AC adapter. RS232 Data output. CE Marked.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair-A, B SELECT
    Tritium and C-14

    Tritium & C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Read out. Computer interface.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Radon
    VADO-Zone/Soil

    VADO-Zone/Soil Air System. Digital. Portable. Detects Radon. Vapor extraction from soil facilitates:

    Pin-point leak source & location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Radon vapor in soil process.

    Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Tritium
    VADO-Zone/Soil

    VADO-Zone/Soil Air System. Digital. Portable. Detects Tritium. Vapor extraction from soil facilitates:

    Pin-point leak source & location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process.

    Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

     

  • All Air and Stack Monitors

    MODEL

    DESCRIPTION

    HIGH-CAPACITY AIR and STACK MONITORS

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CAM-33 Series
    Air/Stack Monitors

    Multi-Channel Air Monitor. Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases with a focus on Noble and Iodine gases. Note: TOTAL-6 focus is on Tritium and C-14. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Total Noble Gas, Noble Gas Curie MeV CAM-3XG. Local and remote alarming, readout, and monitoring of data archive/retrieval. Computer interface.

    Optional: Alpha, Tritium, and Carbon-14 detection are available. Local and remote alarming, readout and monitoring. A Commercial version is available for research labs, room air, and glove boxes. Click here for screenshots

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CAM-33-1P
    Three Channel Air

    Three Channel Air Monitor. Continuous Real-Time. Digital. Caster or Rack Mounted. Detects gross Beta-Gamma, Particulates, Noble and Iodine gases. Flow rate 120 lpm standard. The user is settable. 1" lead shields. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. Click here for screenshots

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CARB-9-14
    Carbon 14 Four Channel Air

    CARBON-14 Air and Stack Monitor. Digital, bench top, line operated. The CARB-F-14 detects airborne concentration of C-14. Separately and simultaneously detects CO, Inorganic C-14, Net Organic C-14, and Particulates. Four channels. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Air and Stack Monitor. Digital. Installed. Continuous Real-Time. Ultra-sensitivity to low-level Tritium (at or Below Public Release Levels). Dose-rate and Dose. Can be located remotely. Archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AC-DC Radiation Monitor. Digital. Portable. The LAM ratemeters are rugged and easy to use for laboratory or field applications. Operated by AC mains or by rechargeable batteries. Works with all of the Technical Associates GM, Proportional, Scintillation, and Solid State probes. The LAM-10D-I has an internal energy compensated probe.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MicroBAM-3ZL Series
    3 Channel Air

    High-Capacity Air Monitor. Digital. Portable. Hand Carry, Cart Mounted (detachable). Three-channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, and Noble Gas and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium air monitor. Digital. Highly sensitive. Includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium in air monitor. Digital. Portable. General-Purpose. Dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarm. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PET-CAM-511
    Positron Air System

    Complete Positron Air Monitoring System for PET (Positron Emission Tomography) facilities. Digital. Installed. Continuous. 9 detector channels. 2 are monitors. Detects Positron, Particulate Beta/Gamma Iodine, Noble Gases. Local and remote readout, alarm, and monitoring. Data archive/retrieval. Computer interface. Easy integration into facility mainframe.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PTG-9-C-14
    Carbon-14 Air/Stack

    Carbon-14 Air/Stack Monitor. Digital. Electronics; Portable or Bench Top. Wide range. A sensitive, rugged, and portable instrument for detection and measurement of airborne C-14. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PTG-9-T
    Tritium Air Monitor

    Tritium Air Monitor. Digital. Electronics; Portable or Bench Top. Wide range. A sensitive, rugged, and portable instrument for detection and measurement of airborne Tritium. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PTG-9-RN
    Radon Air/Stack

    Radon Air Monitor. Digital. Portable or Bench Top. Highly sensitive and rugged. Dual balanced ion chambers. measure airborne radon as free Radon gas (with or without Radon Daughters user’s option) as low as 1pCi/l. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SAAM-1 and SAAM-4HVM
    Six Weeks Unattended Operation

    Moving Air Filter, Alpha Less Radon. Digital. Installed. Alpha, Beta/Gamma. Two models are available:

    • SAAM-1:2-channels, detects gross Alpha & Beta/Gamma (1) GM, (1) ,scintillation detector.
    • SAAM-4HVM: 4-channel, detects gross Alpha, Beta/Gamma, short & long-life particulates. (4) detectors: (1) solid state, (2) GM, (1) scintillation.

    Optional: with SAAM-1 detection of Pu-239, U-238 and/or other nuclides. Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SAAM-1HVM and SAAM-3
    Six Weeks Unattended Operation

    Moving Air Filter, Alpha Less Radon. Digital. Installed. Two models are available:

    • SAAM-1HVM: 2-channel, dual detectors (1) solid-state (1) scintillation. Simultaneous measurement of gross Alpha, Beta/Gamma particulates.
    • SAAM-3: Detects Alpha only. (1) solid-state detector Optional: Detection of Pu-239, and U-238, and/or other nuclides.

    Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SAAM-2VHM
    Six Weeks Unattended Operation

    Moving Air Filter 3 Channel Monitor, Alpha Less Radon. Digital. Installed.

    • SAAM-2VHMSimultaneous measurement of gross Alpha, Beta/Gamma particulates, Noble Gas and Iodine. (3) detectors (2) GM (1) scintillation.

    Optional: Detection of Pu-239, and U-238, and/or other nuclides. Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TOTAL-6
    NPP Stack/Effluent

    Stack Monitor. Digital. Installed. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, and Tritium and C-14 with focus on Tritium and C-14. Optional: Curie MeV channel.

    Note: CAM-33 Series focuses on Iodine and Noble Gas. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. A Commercial version is available for research labs, room air, glove boxes and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    STG-4S/D and STG-5ALT
    Tritium Air Monitor

    Tritium Monitor. Continuous Real-Time. Installed. Stack or Effluent Monitors. Public Release Level, Sensitive, Rugged. No range switching. Audio/visual alarm; Local and Remote, Readout and Monitoring. Data archive/retrieval. Computer Interface.

    • STG-4S/D Digital, 6 decades, auto-ranging.
    • STG-5ATL Analog 4 decades, Log scale. Measures Tritium as HTO in presence of other radioactive gases.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AIR and STACK: PORTABLE and BENCH TOP

    CAM-33 Series
    Air/Stack Monitors

    Multi-Channel Air Monitor Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases with focus on Noble and Iodine gases. Note: TOTAL-6 focus is on Tritium and C-14. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Total Noble Gas, Noble Gas Curie MeV CAM-3XG. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface

    Optional: Alpha, Tritium, Carbon-14 detection is available. Local and remote alarming, readout and monitoring. A Commercial version is available for research labs, room air, glove boxes.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FASTCAM-5
    Plutonium Air Monitor

    Quick Response Plutonium Air Monitor. Digital. Portable. Electronics; Portable or Bench Top. Sees Alphas and Betas in high or varying background situations. Two different detectors. Stand alone or networked with other detection locations. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9ABNI
    PET/Iodine/99m

    PET, Iodine, Tc-99m DTPA Air Monitor. DigitalPortable. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Application: Hospitals / Research, Power Plants, National Labs. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PORTABLE, SURVEY, SAMPLER, RATEMETER

    ABG-NET Series
    Networked or Standalone
    Air Monitor

    Networked or Standalone Air Monitor. Digital. Portable or Installed. Detects Alpha, Beta Particulates, Ambient Gamma. 1 or 2 channel options. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    • ABG-NET One channel
    • ABG-R-NET Second channel for Radon Moving filter head

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AIR-TBM
    Multi Use Monitor

    Alpha, Beta, Gamma Air Monitor / Wipe Counter / Survey Monitor. Digital. Portable. TBM-3SR-D electronics with built-in T-1190 GM Pancake Detector. Local Readout. Computer interface. Perfect for First Responders, Hospitals, Clean Up sites, Pharmacies, etc. Battery or AC powered.
    Click For GM Pancake Tube Response Report.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AIR-TBM-SP
    Air / Wipe / Survey Monitor

    Alpha, Beta, Gamma Air Monitor. Wipe Counter / Survey Monitor. Digital. Portable All-In-One Multi-Use Radiation Monitor System uses LAM-10D electronics. 2 detectors: (1) STB-3 Alpha/Beta Sample/Wipe Counter; (1) Gamma-Source Search Tool; PGS-3 Scintillation probe. Ideal for First Responders. Local readout. Computer interface. Optional: Relay for operating other equipment, door locks, fans, etc. Battery or AC powered.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AP Series
    Quiet, Oil-less Green Turtle Air Pump

    Quiet, Oil-less Air Pump. Models with flow rates from. 48 lpm – 190 lpm. Aluminum housing.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AS-30-Be and AD-30-Be
    High Volume Air Sampler
    and Totalizer Monitor

    High Volume Beryllium Air Sampler and Detector. Digital. Portable. AS-30-Be air sampler. AD-30-Be detector with continuous surveillance with GM detector. User settable flow rate 10-100 lpm. Room, Hood, or Stack. Local readout. Perfect for Hospitals, Cleanup sites, Pharmacies, etc.

    • Optional: RS-232 or RS-485, or Ethernet
    • Optional: Data Storage (Flow Rate and Sample Duration)

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AS-100 Series
    High Volume Air Sampler
    and Totalizer Monitor

    High Volume Air Sampler and Totalizer Monitor. Digital. Portable. Programable electronics. Flow rate 227 lpm. Room, Hood, or Stack. Local readout. Computer Interface. 3 models. Perfect for Hospitals, Cleanup sites, Pharmacies, etc.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    BAM-STAM-3Z Series
    Alpha, Beta, Gamma

    Alpha, Beta, Gamma. Digital. Portable (Hand Carry). Cart Mounted (detachable). Sampler with dual detectors system. Standard:

    • Multi-Channel Alpha Analyzer (MCA) BAM-STAM-3Z
    • Single-Channel Gamma Analyzer (SCA) BAM-STAM-3Z

    Optional: Three detector system. BAM-STAM-3ZG. Alpha, Gamma, Plutonium. Optional: Multi-Channel Gamma Analyzer (MCA) BAM-STAM-3ZG
    Includes Counts, wipes, filters, and planchets. laptop and software. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium and C-14 Surface Contamination Meter. Digital. Portable. Gas flow proportional detector. Use for flat surfaces. 100cm2 sensitive area. Local readout. Optional: probe for hands, clothing and equipment.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-BG
    FM-9-BG-C

    Beta/Particulate Monitor

    Beta / Gamma Particulate Monitor. Digital. Portable. T-1190 GM detector. Flow rate 70 lpm standard. The filter is under constant surveillance via a thin window GM pancake detector. FM-9-BG-Chas a cyclone particle separator. Data archive/retrieval. Computer interface. Click For GM Pancake Tube Response Report.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Rapid Radon Monitor. A System for Quick Measurement. A Collection Unit with a Quiet Pump and Charcoal Filter Holder with a Scintillation Counter/Scaler. Portable AC. 1 pCi/l in 3 Minute Sampling. Increased Sensitivity with Longer Sampling. Replacement Cartridges Widely Available PRS-7 Electronics. Battery or AC. Computer Interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Lightweight Digital Frisker. Dual GM Pancake Sensors in paddle form with handle. Battery operated. Gamma detection. Portable. Electronics – PRS-2. 2 Separate scale factors for Rate and Total. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FR-PIB Series
    Iodine Total Air Activity

    Iodine Monitor Total Airborne Activity. Digital. Portable. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user-settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector. Line operated. Local readout. Data archive/retrieval. Computer interface.

    FR-PII-Pb uses ½" lead shield. Use as industrial workplace and hospital breathing air measurement system, and to monitor fume hoods and stack effluent down to EPA levels.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chromatogram Scanning Counter. Portable. Digital. AC. The HY-1 is a Medical Isotope System. It is an automatic scanner for TLCs, gels, paper chromatograms, and electrophoreses, to allow immediate visualization and estimation of isotopic content. Includes MCA. On board computer and Computer interface for data download.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Chromatogram Scanning Counter. Benchtop. Digital. AC. The HY-1 is a Medical Isotope System. It is an automatic scanner for TLCs, gels, paper chromatograms, and electrophoreses, to allow immediate visualization and estimation of isotopic content. Accepts 3 detector types: GM, Gas Flow, and Scintillation. Scans 6 traces simultaneously. A moving 10" x 20" table carries two 20cm x 20 cm TLCs or other samples in controlled steps under a bridge, examines samples' traces, and transfers information to a printer or strip chart recorder. Detectors are interchangeable.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AC-DC Radiation Monitor. Portable. Analog. The LAM ratemeters are rugged and easy to use for laboratory or field applications. AC or DC power. LAM-10 Electronics work with all of the Technical Associates GM, Proportional, Scintillation, and Solid State probes. Local Readout, Optional: USB.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    METHANE-TA Series
    Methane Leak Detector

    • Methane-TA1 Digital, portable, battery operated, hand held. Data archive/retrieval. Computer interface. Local readout. User settable alarm. Detects multiple gases, user settable.
    • Methane-TA2 Digital, portable or installed, battery or AC power, hand held. Local readout. User settable alarm (high or low) Detects multiple gases, with interchangeable sensor heads. Data archive/retrieval. Computer interface. Optional: remote sensor capability. Optional: temp and HR sensor.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MINI-AIR-RAD Series
    Personal Mini-Air Sampler

    Personal Mini-Air Monitor Series. Digital. Portable. Continuous. Miniature pump 1-3 lpm. Integrated exposure. (2) Options: (1) Mini-Air, Sampler only, no read out (2) Mini-Air-RAD, Sampler and local read out. Full System (Big Bro) Total Airborne activity 6x10-8 uCi/cc in 30 minutes for Big Bro.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MINI-AIR-Be
    Personal Beryllium Air Sampler

    Personal Beryllium-Air Sampler. Digital. Portable. Continuous. Miniature pump 1-3 lpm. Integrated exposure. Collection of Beryllium particulates. Onboard memory for data retrieval via data access. Uses 47 mm or 140 mm filters. User specified. USB, rechargeable batteries, and charger.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Mobile High Volume Cart Mounted Air Sampler and Totalizer. Digital. Portable. Draws the room air in onto quick-change filters, 2"- 4" or 4"- 8" Mobl-Air-8. Adjustable breathing air intake height. Inlet/outlet hose provides versatility for hoods, glove boxes, stacks, etc. Optional: Battery power. Standard air flow is 48-200 lpm with a quiet Green Turtle pump.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Mobile High Volume Cart Mounted Beryllium Air Sampler and Totalizer. Digital. Portable.Draws the room air in onto quick-change filters, 47mm or 147mm diameter glass fiber filters. Adjustable breathing air intake height. Inlet/outlet hose provides versatility for hoods, glove boxes, stacks, etc. Optional: Battery power. Standard air flow is 10-100 lpm. Optional: 227 lpm with a quiet Green Turtle pump.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium survey monitor. Digital. Portable. No zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO discriminating version. Local display.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NSN3 Neutron Survey Meter. Designed for Nuclear Reactors, Neutron Sources and Generators, customs inspections, etc. Portable, light weight with fast count and zero drift. Measures ambient dose equivalent and ambient dose rate equivalent of neutrons.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PRS-2 Series Automatic Scalers. Simultaneous dual readouts. Digital. Portable. PRS-2S has no energy discrimination. PRS-2F has energy discrimination. Local readout. Optional: USB Computer interface. Use with a wide variety of detectors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Analyzing Ratemeter Scalers. Digital. Portable. The PRS-7 is a Single Channel Analyzer. Dual Channel Analyzer PRS-7-DSC with two independent detector inputs and coincidence circuit. Both models have integrate and ratemeter functions. Three presettable window positions. Local readout. Optional: USB Computer interface. Use with a wide variety of GM, Proportional, and Scintillation Probes.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Universal Survey Meter. Portable. Digital or Analog. Use with Technical Associates GM, Proportional, Scintillation, Solid-State Probes. Alpha, Beta, Gamma, Neutron, X-Ray. Six decades. Four range survey meters. The readout is in microR/h (or SI units). Three models: PUG-7-D - alarm. PUG-70-D – User Settable Alarm.  PUG-7-DF – Full System includes PUG-7-D Electronics with PGS-3 (one inch Nal(TI) scintillator) Gamma Probe. Battery operated. Optional: AC. Local Read Out.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Neutron PUG. Portable. Analog. Detects fast (PNS-19) or slow/fast Neutrons (PNS-20) and favors slow Neutrons. It is lightweight and includes electronics, a moderator, and a probe. Battery operated. Local Read Out.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Neutron PUG. Portable. Analog. Detects fast (PNS-19) or slow/fast Neutrons (PNS-20) and favors slow Neutrons. It is lightweight and includes electronics, a moderator, and a probe. Battery operated. Local Read Out.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AREA MONITORS

    DSI-2-ITS
    Network Radiation Tracking System

    Networked Radiation Tracking System. Digital. Portable or Installed. Can network with existing surveillance systems. Detects Gamma and Neutron. Gamma - NaI (or BGO) Scintillation detector. Neutron - BF3 Proportional Probe. Easy placement of detectors and integration into existing systems. Sensitive, wide range. Remote access and wireless notification are available. Computer interface with RS-232 or ethernet data collection. Alarm user-settable.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FIL-9DP
    Wide Range Ion Chamber Area Monitor

    Wide Range Area Monitor. Digital. Portable, Bench Top, Rack Mount, Wall Mount, or NEMA cabinet for hostile environments. Detects Gamma and Beta. Electronics: digital alarm ratemeter LAM-10D, built-in battery pack with charger, electrometer, and ion chamber.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FML-9W-GM
    Area Monitor

    Wide Range Beta-Gamma GM Area Monitor. Single or Multi Channel. Digital. Rack or Wall mount. For in and around nuclear reactors, hot cells irradiators and other facilities handling radioactive materials or x-rays. Local or Remote monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Neutron Air Monitoring System. Digital. Installed or Rack Mounted. Moderated proportional BF3 neutron tube. Use for tracking the level of Neutron radiation present in and around nuclear reactors, accelerators, neuron sources, and generators, etc. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9W Series
    Wide Range Area

    Wide Range Area Monitor. Digital. Bench Top or Installed. Detects Beta, Gamma, X-Ray. Optional: Neutron. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Use with wide range of TA detector types. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LAM-10-D with PGS-3
    Radiation Control Monitor

    Radiation Control Monitor. Exit/Doorway Monitor, Package/Mail Monitor, Vehicle Monitor, Laundry Monitor. Digital. Installed. Detects Beta/Gamma. Mount above sorting table, conveyor belt, or doorway. Electronics: LAM-10-D Ratemeter. Audio visual alarm. Optional: Wireless remote notification – phone, email, text, video recording. Local readout. Computer interface. (2) models:

    • PGS-3 1" x 1" scintillation crystal.
    • PGS-3-L 2" x 2" scintillation crystal.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LoGAM-E/W
    Environmental Gamma Air Counter

    Very Low Range Environmental Gamma Counter. Continuous Real-Time monitoring detects small changes in ambient radiation levels. Replaces traditional 'PIC' detectors. Current Regulations and Environmental concerns demand ever lower levels of Gamma Flux measurement. Data archive and retrieval. Local and remote read out and alarm. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    • OXY-IS-D AIR - Oxygen measurement for ambient oxygen in the air. Wall mount. Diffusion style. No pump. Local readout or Computer interface.
    • OXY-IS-DF AIR - Oxygen measurement for process oxygen. Wall mount. or benchtop. Flow-through style. Quiet Air pump, 30 lpm.
    • Both OXY-IS-D and OXY-IS-DF - Dual scale 0-25%; 0-50%. Sensitivity 0.5% O2 in the air by volume. Local readout or Computer interface.
    • OXY-IS-DSUB WATER - Portable. Digital. Dissolved oxygen. Non-fouling cell diffusion style submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.
    • OXY-IS-DFW WATER - Dissolved oxygen. Non-fouling cell flows through submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PLASMA-ACC
    TBM-ACC-X

    High Energy Accelerator
    Plasma Chamber System

    This is a Plasma Chamber® for an Area Monitor for a High Energy Accelerator. Digital. Installed or portable TBM-ACC-X. The PLASMA-ACC is the only accelerator plasma chamber® that will detect nanosecond pulsed X-Rays. It will accurately measure the integrated Total Dose from pulsed X-Ray machines over a wide range of pulse widths and repetition rates.
    Installed model – Plasma-ACC. Data archive and retrieval. Local and remote read out and alarm. Computer interface. Portable TBM-ACC-X: Local digital read out.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PORTABLE and BENCH TOP AIR MONITORS

    Portable Gamma Micro-R Meter Plus Neutron. The DSI-2GN-L Precision Radiation Proximity analyzer is small with unprecedented sensitivity and accuracy. The DSI-2GN-L is designed specifically for use by inspectors and guards, police, and hazmat squad to give warning in case of illicit or accidental storage or transport of radioactive and fissile material. Suitable uses are for shipment inspectors both in the USA and overseas. Also power plants, environmental and industrial inspectors, and steel mills. Also in hospitals, landfills, and at customs entry and exit points. The DSI-2GN-L is also useful as a µ R/hr meter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-AB2 / FM-9-AB2-Be
    Alpha/Beta/Gamma/Beryllium Air

    Alpha/Beta/Gamma/Beryllium Air Monitor. Digital. Portable or Bench Top. Continuous. Local Readout. Data archive/retrieval. Computer interface.

    • FM-9-AB2 dual detectors (1) GM Pancake. (1) Scintillator.
    • FM-9-AB2-Be added Beryllium filters. Flow rate 70 lpm standard, user-settable.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-IXE
    Iodine-125/Xenon-125 Ratemeter

    Iodine-125 and Xenon-125 Ratemeter. Digital. Installed. Continuous Quick connect Xenon detector. Quickly connect the Iodine detector and filter cartridge. Use for the stack, hood, glove box, or area air. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9XE
    Xenon-133 Monitor

    Xenon-133 Gas Monitor. Digital. Installed. Continuous. Flow rate 10 lpm standard. Local readout. Pre filter removes particulates. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MABC
    Radiation and Chemical Monitor

    Multiuse Radiation and Chemical Air Monitor. Digital. Bench Top. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination is available. 1 each for a solid-state detector for Alpha and Beta particulates. Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MA2 Series
    Alpha, Beta Particulate, Thoron & Radon

    Thoron and Radon Gas Air Monitors. Alpha, Beta Particulate. FM-9-MA2 Series: Digital, Portable, Installed. Real-Time operation. Local or Remote Sampling and Read Out. Data archive/retrieval. Computer interface.

    • FM-9-MA2 - Alpha Only
    • FM-9-MAB2 - Alpha and Beta
    • FM-9-MAB2-M - Mobile. Moving filter head for FM-9-MAB2-M only.
    • FM-9-MA2-T - Gas Ion Chamber is added to the Alpha and Beta detector system.
    • FM-9-MA2-R Radon - Gas Ion Chamber is added to the Alpha and Beta detector system.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MCA
    PET/Iodine/Tc-99m

    PET, Iodine, or Tc-99m DTPA Air Monitor. Digital. Bench Top. Multi-Channel Analyzer (MCA). Continuous. Monitor air room or stack effluent. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MCA-2
    Iodine-125/Gas/Particulate

    Iodine-125 Air Gas and Particulate Air Monitor. Digital. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Computer interface. Flow rate 70 lpm standard.

    Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-M2
    Beta Particulate System

    Beta Particulate Air Monitor System. Digital. Bench Top. Continuous. 2 GM detector system. (1) Beta Particulates, (1) for Dynamic Background Subtract. Integrated exposure. Local and remote continuous real-time sampling. Quick change filter. Electronic Mass Flowmeter. Data archive/retrieval. Computer interface. Expandable system with FM-9 series modules. Click For GM Pancake Tube Response Report.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9W-V
    Radiation Control

    Radiation Control Monitor. Digital. Bench Top or Installed. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Accommodates over 50 types of detectors.

    • Exit/Doorway Monitor
    • Package/Mail Monitor
    • Vehicle Monitor
    • Laundry Monitor

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9NGAS Series
    Noble Gas Monitor

    Noble Gas, Argon, Xenon, Krypton Monitor, or Leak Detector. Real-time, continuous, digital display. Five models to choose from including the cart-mounted FM-9XE-NGL Leak Detector and the 10 scintillation detector model FM-9NGAS-10S. Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Neutron PUG. Portable. Digital. Detects fast (PNS-19) or slow/fast Neutrons (PNS-20), and favors slow Neutrons. It is lightweight and includes the electronics, moderator, and probe. Battery operated. Local Read Out.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SFM-9V Series
    Low Background

    Low Background Gas Flow Alpha and Beta Counting System. Digital. Benchtop. This system produces high counting efficiencies for measuring extremely low levels of Alpha and Beta radioactivity with a detect-reject cosmic ray feature. Includes a sample detector and a guard detector. Ideal for applications in biological, physical, and chemical research or in environmental sampling for health physics and public health services. The instrument includes a sample tray holder that accepts 1'' SFM-PV-1 or 2” SFM-PV-2 samples. FM-9 Smart Electronics, computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair-A, B Select
    Tritium and C-14

    Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Read out. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Radon
    VADO-Zone/Soil

    VADO-Zone/Soil Air System. Digital. Portable. Detects Radon. Vapor extraction from soil facilitates: Pin-point leak source and location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Radon vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Tritium
    VADO-Zone/Soil

    VADO-Zone/Soil Air System. Digital. Portable. Detects Tritium. Vapor extraction from soil facilitates: Pin-point leak source and location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Nuclear Power

    Nuclear Power

    MODEL

    DESCRIPTION

    NUCLEAR POWER: SYSTEMS

    FML-W9 GM
    Area Monitor

    Digital. Rack or Wall Mount.

    Wide Range Beta-Gamma GM Area Monitor. Single or Multi-Channel. For in and around nuclear reactors, hot cell irradiators, and other facilities handling radioactive materials. Local or Remote monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9W Series
    Area Monitor

    Digital. Bench Top or Installed.

    Wide Range Area Monitor. Detects Beta, Gamma, and X-Ray. Optional: Neutron. Continuous. Multichannel Analyzer (MCA). Relay can lock doors, trigger a siren or send an alert. Use a wide range of TA detector types. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Accommodates over 50 types of detectors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9W-IC-25HT
    NPP Process Monitor

    Digital. Rack Mounted.

    Nuclear Power Plant Process Monitor. Safety Class Qualified for NPP use. Detects Gamma, and rejects thermal Neutron, Alpha, and Beta. High-pressure sealed ionization chamber with mineral insulated cable. (2) Electronics: Single or multichannel. (1) single channel (FM-9W). (1) multichannel (FM-9WHUB). Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Portable.

    The NSN3 Neutron Survey Meter is designed for Nuclear Reactors, Neutron Sources, Generators, customs inspections, etc. Lightweight with fast count and zero drift. Measures ambient dose equivalent and ambient dose rate equivalent of neutrons.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    ORO
    Radiation Overview

    Digital. Installed.

    Overhoff Radiation Overview. Map the facility in a series of views linking multiple instruments, installed and portable, and readings from various areas to the facility mainframe and individually in each area including the perimeter. Software package: readout, mapping, reporting. Easy integration into facility mainframe. A wide variety of reports are available.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RMS-RR
    Repair and
    Replacement

    Digital. Rack or Wall Mounted.

    RMS repair and replacement services for all manufactured RMS models. Orphan and legacy, and hard to find replacement and repair. TA provides replacement detectors with longer life along with cost savings. Nuclear power plant detectors, monitors, and systems.

    Problem: detectors and monitors break, degrade, or replacement parts are no longer available. Technical Associates fills this need: Build an exact fit and function replacement detector with the same or longer life span; use the highest quality parts and components, often the same brand as the original; provide reasonable pricing; rebuild “burned out” detectors scheduled for discard; provide dependable, perfectly working spares.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RMS-TA
    Nuclear Power RMS Systems

    Technical Associates provides standard and custom-designed Radiation Monitoring Systems (RMS) and equipment to nuclear power plants globally including the United States, Canada, United Kingdom, Sweden, France, Korea, Japan, China, and other countries.

    TA's Digital Radiation Monitoring Equipment is a complete Multinuclide instrument product line. This includes off-line and in-line liquid effluent, water and air monitors, particulate and, Noble Gas monitors, Tritium, C-14, Radon, Thorium, and Iodine monitors as well as area and atmosphere monitors. TA also provides accident and post-accident monitors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FACILITY INFRASTRUCTURE

    Drone Flight Platform
    UAV Air Forensics

    Technical Associates, a division of US Nuclear Corp, utilizes a variety of UAV flight platforms. The UAV selected is to meet the customer’s mission requirements. The selection regardless of model or manufacturer is Weather resistant to heavy-lift commercial UAVs. Automatic return to home, autonomous waypoint capability, intelligent flight modes, commercial-grade carbon fiber frame, GPS position and hold, Flight telemetry overlay, stable in 20 mph (32 km/h) wind.

    Optional: Sense and Avoid. Payload up to 11 pounds, 6 commercial-grade heavy-lift motors. Flight times up to 70 minutes, dependent on payload weight, speed 35 mph, (56 km/h), FPV camera, and real-time video downlink. USA made. Fly Detectors Together or Separately. Optional: Cameras - User-specific. Note: UAV Platform Is Selected To Meet User’s Mission Requirements.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DroneRAD-P
    UAV Air Forensics

    Digital. Portable.

    Plume detector. UAV-mounted DroneRAD System. Alpha, Beta, Gamma, C-14. Aerial radiation detector DroneRAD software, built-in air pump, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Air Monitor and Plume detection DroneRAD-P. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    DroneRAD-ST
    UAV Air Forensics

    Digital. Portable.

    Search Tool fixed source-detector. UAV-mounted DroneRAD System. Gamma, optional Neutron aerial radiation detector, DroneRAD software, radiation mapping data tool. Real-time wireless data download transmission to the included ground station. Downward-looking Gamma and optional Fast Neutron spotters for ground, building, vehicle, and facility air surveillance. DroneRAD-ST. Easy Installation. Fast deployment. Immediate results. Local readout and monitoring. Display map. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    WATER & LIQUID EFFLUENT MONITORS

    Digital. Portable.

    High-Range Submersible Ion Chamber. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven (Model CP-MU) coupled to a submersible ion chamber, 60 feet of special low noise cable with a waterproof coupling to the detector. Local readout. Optional: Computer interface. Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Portable.

    High-Range Submersible Monitors. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven Model CP-MU coupled to specific ion chamber detectors for use monitoring reactor core and fuel pool and their components. Very High Range. Local readout. Optional: Computer interface. Five Linear Ranges:

    • CP-MU-D1: GAMMA High Range
    • CP-MU-D100: GAMMA Mid Range
    • CP-MU-D1000: GAMMA Low Range
    • CP-MU-7-D1: GAMMA Very High Range
    • CP-MU-GN: Gamma and Neutron Proportional Detector.

    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    D2O-STA and D2O-FTA
    Deuterium Oxide

    Digital. Portable or Benchtop.

    D2O-STA sampler detects deuterium oxide in water, liquid, or gas. No sample preparation is required. Infrared spectrometry. Attenuated total reflectance (ATR). The small size allows positioning inside the glove box or fume hood. Touch panel display. D2O-STA with TA-specific software. AC power with rechargeable battery backup. Quick-snap sampling module. 10-year laser warranty. Computer interface. Optional: Flow through feature – D2O-FTA.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Under Water High-Capacity Ion Chamber Probes. Used with the CP-MU series of electronics.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FPT-H3 Series
    Fuel Pool Tool

    Digital. Installed.

    Fuel Pool Tool. Detects Tritium in NPP pool water, and pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only (FPT-H3). (1) Tritium plus Alpha-Beta-Gamma Detectors (FPT-H3-ABG). Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LIQ-X(H3)
    Tritium in Water

    Digital. Benchtop.

    Tritium in Water Monitor. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory, or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18.

    For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Ultra-Sensitive Tritium in Water Monitor. Heavy water leak detector. Fully automated, real-time, and continuous. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water. Integrated computer with custom software and large LCD display. Monitors water below the EPA drinking water standard of 20,000 pCi/l. Computer interface with ethernet and USB.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Multi-detector air monitor for Molten Salt Thorium Reactors. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14, and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MSTR-H2O
    Thorium Reactor Water

    Digital. Installed.

    Molten Salt Thorium Reactor Water Monitor. Real-time Continuous. Detects Thorium, Tritium, Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. In-Line or transportable (Rack Mounted or Wheeled Base)

    Drinking/Waste Water Monitor. Continuous Real-Time. Detects Gamma. Monitor ground, surface water, and industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TL) or HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    • Optional: Detectors: Alpha, Beta, Tritium, Radon
    • Optional: Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NEXGEN-SEA
    Sea Water Monitor

    Digital. Installed.

    Sea Water Monitor Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    Optional: Ozone System.
    Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Bench Top or Rack mounted

    Tritium Water Monitor. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Meets EPA drinking water levels. Strategy for Measurement of Tritium in Water / Oil Mixture

    • Monitor Leaks in Candu Type Reactors
    • Monitor Tritium Contamination in Ground Water.
    • Monitor Laboratory or Plant Liquid Waste Stream.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NPP-H2O
    Nuclear Power Water

    Digital. Installed.

    Nuclear Power Water Monitor. Continuous Real-Time. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, and Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PEMO-7
    Strap-On Pipe Monitor

    Digital. Installed.

    Strap-On Water Pipe Monitor Series. Continuous Real-Time. Gamma detection. Flow rate is not a factor. Constant check and alarm. Single channel (SCA) or multichannel analyzer (MCA) models. Detection for PEMO-7 and PEMO-7-MCA is with a NaI (Tl) scintillation crystal detector. Detection for PEMO-7-G is with an HPGe solid-state detector. Electronics is the FM-9W Read Out for use with multiple detectors. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PEMO-7LE
    Strap-On Pipe Monitor

    Strap-On Pipe Monitor Series. Digital. Portable. Flow rate is not a factor. Constant check and alarm. Single channel (SCA) and multichannel analyzer (MCA) models. Local and remote alarm, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Low range liquid scintillation system accurately quantitatively measures Carbon-14, Tritium and most other radioactive materials. Measures low levels of Tritium even below 20,000 pCi/l, Clean Drinking Water Levels.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SSS-22P Series
    Liquid Scintillation

    Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Multichannel Analyzer SSS-22-MCA, suitcase version of SSS-22P SSS-22PAL, lab version of SSS-22P SSS-22LAB. Local readout and alarm. Computer interface. Optional: 6 sample adapters.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TASC
    Tritium/C-14 Sampling

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit Tritium sampler and concentrator from stacks, hoods, room air, the outside environment or other areas. System includes: Specific chemical reagents for Tritium or C-14, sample bottles, pump, mass flow controller and regulated oxidizer. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TRIMARAN H2O
    Ultra Low Tritium Water

    Ultra Low-Level Tritium Water Continuous Real-Time Monitor. Digital. Installed. Designed for near real time ultra-low level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LAUNDRY

    LIM-64S
    Laundry Sorter/A-B

    Laundry Monitor. Digital. Installed. Detects Beta/Gamma. Dual fast flow sorting (clean vs contaminated) conveyor belts. Detectors are mounted above and below the conveyor belt. (6) 8" x 8" Beta scintillation detectors mounted above a conveyor belt in a conveyor belt rack. Sensitive area 642 inches (412 cm2) for each detector. (4) 2" x 12" Gamma scintillation detectors mounted below the conveyor belt. Sensitive area 242 inches (155 cm2) for each detector.

    Electronics: Wall or Rack Mounted. (10) channels, audio/visual alarms on each channel. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Laundry Inspection Monitor. Digital. Portable. Simplified laundry monitor. Fast response. Settable alarm. Lead shielding on detectors. Audible and visual alarms. P-10 hand probe for localizing contamination. Detectors in the Portable frame. Eight channels. (1) T-1110 GM Tube in Hand Probe P-10 with both LIM-19 and LIM-20.

    • LIM-19 - (6) T-1120 Halogen-Quenched GM Tubes Single channel
    • Lim-20 - (8) T-1120 Halogen-Quenched GM Tubes

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed. A high sensitivity Beta/Gamma Monitoring conveyor system for determining possible radiation contamination in garments or hazmat (PPE) garments. (8) large area of flat plastic scintillation sheets, (4) on each side.

    • The conveyor brings garments on hangers forward and then turns each vertically hanging garment into a perpendicular position.
    • Garments move between the two towers for simultaneous detection on both sides of the garment for contamination.
    • As the conveyor progresses the garments are sorted onto either the ‘contaminated’ conveyor or the ‘clean’ conveyor.

    The LIM-OH-8 is a dependable, long, life mechanical system with advanced computer and data processing.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Laundry Conveyor Monitor-21. Digital. Installed. (2) models: Detects Beta (LIM-GFA) and Beta/Gamma (LIM-GFAT). Single fast flow-through 6-foot-long conveyor belt. (8) Gas proportional detectors mounted in a conveyor belt rack. Electronics: Wall or Rack Mounted. (8) channels with audio/visual alarms for each channel. Sensitive area 622 inches (400 cm2) for each detector. Local readout and alarm.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Transportable. A high sensitivity Gamma Monitoring system for determining possible radiation contamination in laundry, carts, packages, or hazmat (PPE) garments. The ‘pass through’ between two towers, each with 3 plastic scintillation sheets, can be direct straight through or paused between the towers for higher sensitivity. Optional Neutron detectors. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    AIR AND STACK MONITORS

    CAM-33 Series
    Air/Stack Monitors

     

    Multi-Channel Air Monitor Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases with a focus on Noble and Iodine gases. Note: TOTAL-6 focus is on Tritium and C-14. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Total Noble Gas, Noble Gas Curie MeV CAM-3XG. Local and remote alarming, readout, and monitoring. Data archive/retrieval. Computer interface.

    Optional: Alpha, Tritium, and Carbon-14 detection is available. Local and remote alarming, readout, and monitoring. A Commercial version is available for research labs, room air, and glove boxes. Click here for screenshots

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Low Range Tritium Wipe Test Counter. Portable. Measure down to 500DPM. 3" Sample drawer. The unique ion chamber sample counter provides low-range Tritium measurement and eliminates the need for a pressurized gas supply or LSA cocktail. USB Output. User-specified engineering units.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    High-Range Tritium Wipe Test Counter. An Ion Chamber Sample Counter with FM-9 Smart Electronics. Designed for low energy, HIGH activity counting. Ideal for fusion research or in Tritium production and use. Choice of 5 decades or Optional: 8 decades. No LSC or pressurized gas requirement equals no Waste. Computer Interface.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    D2O-STA and D2O-FTA
    Deuterium Oxide

    D2O-STA sampler detects deuterium oxide in water, liquid, or gas. Digital. Portable or Benchtop. No sample preparation is required. Infrared spectrometry. Attenuated total reflectance (ATR). The small size allows positioning inside the glove box or fume hood. Touch panel display. D2O-STA with TA-specific software. AC power with rechargeable battery backup. Quick-snap sampling module. 10-year laser warranty. Computer interface. Optional: Flow through feature – D2O-FTA.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FIL-9DP
    Wide Range Area Monitor

    Wide Range Area Monitor. Digital. Portable, Bench Top, Rack Mount, Wall Mount, or NEMA cabinet for hostile environments. Detects Gamma and Beta. Electronics: digital alarm ratemeter (LAM-10D), built-in battery pack with charger, electrometer, and ion chamber.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-REM
    Neutron Air System

    Neutron Air Monitoring System. Digital. Installed or Rack Mounted. Moderated proportional BF3 neutron tube. Use for tracking the level of Neutron radiation present in and around nuclear reactors, accelerators, neutron sources, generators, etc. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9ABNI
    PET/Iodine/99m

    PET/Iodine/99m PET, Iodine, Tc-99m DTPA Air Monitor. Digital. Portable. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9-MCA
    PET/Iodine/Tc-99m

    PET, Iodine, or Tc-99m DTPA Air Monitor. Digital. Bench Top. Multi-Channel Analyzer (MCA). Continuous Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional: lpm available. Monitor air room or stack effluent.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9NGAS
    Noble Gases, Argon, Xenon, Krypton

    Noble Gas, Argon, Xenon, Krypton Monitor, or Leak Detector. Real-time, continuous, digital display. Five models to choose from include the cart-mounted FM-9XE-NGL Leak Detector and the 10 scintillation detector model FM-9NGAS-10S.

    Chamber volume 300cc, 600cc, 1 liter. Use GM or scintillation detectors. Local Readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FR-PIB Series
    Iodine Total Air Activity

    Iodine Monitor Total Airborne Activity. Digital. Portable. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector (FR-PIB) or scintillation (FR-PII) detector. Line operated. Local readout. Data archive/retrieval. Computer interface.

    FR-PII-Pb uses ½” lead shield. Use as industrial workplace and hospital breathing air measurement system, and to monitor fume hoods and stack effluent down to EPA levels.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Air and Stack Monitor. Digital. Installed. Continuous Real-Time. Ultra-sensitivity to low-level Tritium (at or Below Public Release Levels). Dose-rate and Dose. Can be located remotely. Archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LOGAM
    Ultra Low Gamma

    Very Low Range Continuous Environmental Gamma Counter. Digital. Portable. Detects gamma flux with a gain stabilized scintillator. Tripod mounted sensor. Installed electronics. Gamma spectrum and isotope identifier. Multichannel Analyzer (MCA). Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MicroBAM-3ZL Series
    3 Channel Air

    High Capacity Air Monitor. Digital. Portable. Cart Mounted or detachable Hand Carry. Three channel air monitors for simultaneous measuring of gross Beta-Gamma Particulates, and Noble Gas and Iodine. Multichannel Analyzer (MCA) MicroBam-3ZL-G-ID Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NHL-4
    Gamma Pocket Dosimeter

    Dual Detector Wide Range Gamma Pocket Dosimeter. Digital and Analog. Portable. Detects Gammas, X-Rays. Alarming Gamma Rate and Dose Meter. Dual detector: Scintillator and Silicon Semiconductor. Dose and dose rate. Rugged, dust and water proof. function. Rechargeable batteries. EMF interference resistant. GPS search tool. Excellent for police, first responders, airport, and security personnel. USB.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Wide Range Gamma Pocket Dosimeter. Digital. Portable. Compact, lightweight, impact resistant with long battery life. EMF interference resistant. Measures dose equivalent. Data download via reader.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NRF31
    Gamma/X-Ray/Neutron

    Gamma, X-Ray, Neutron Pocket Dosimeter. Digital. Portable. Dose and dose rate. Compact, lightweight, impact resistant with long battery life. EMF interference resistant. Data download via reader.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NRF34
    Gamma/X-Ray/Neutron

    Gamma, Beta and X-Ray Pocket Dosimeter. Digital. Portable. Compact, lightweight, impact resistant with long battery life. Measures dose equivalent. EMF interference resistant. Data download via reader.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    • OXY-IS-D AIR - Oxygen measurement for ambient oxygen in the air. Wall mount. Diffusion style. No pump. Local readout or Computer interface.
    • OXY-IS-DF AIR - Oxygen measurement for process oxygen. Wall mount. or benchtop. Flow-through style. Quiet Air pump, 30 lpm.
    • Both OXY-IS-D and OXY-IS-DF - Dual scale 0-25%; 0-50%. Sensitivity 0.5% O2 in the air by volume. Local readout or Computer interface.
    • OXY-IS-DSUB WATER – Portable. Digital. Dissolved oxygen. Non-fouling cell diffusion style submersible to 60 ft (18m) water depth. The module is available in the 0-20 ppm range. Ideal for aeration lagoons, sewers, etc. Data download up to 5 miles via a transmission cable.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SAAM-2HVM
    Six Weeks Unattended Operation

     

    Moving Air Filter 3 Channel Monitor, Alpha Less Radon. Digital. Installed.

    • SAAM-2VHMSimultaneous measurement of gross Alpha, Beta/Gamma particulates, Noble Gas and Iodine. (3) detectors (2) GM (1) scintillation.

    Optional: Detection of Pu-239, and U-238, and/or other nuclides. Unattended operation up to 6 weeks. Counts separately and simultaneously. High-capacity air pump; flow rate standard: 4cfm. Optional: 30 cfm. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TBM-IC-HLS
    Wide Range Monitor

    Wide Range Ion Chamber. Digital. Portable. Alpha, Beta, Gamma, X-Ray. Detects X-Ray Pulse down to 0.002μR. Wide range 0.1mR/hr to1,000R/hr. ANSI N42.33 Homeland Security Type 2.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair
    Tritium and C-14

    Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Read out. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriMaran – Air/Stack
    Ultra Low-Tritium

    Ultra Low-Level Automated Tritium Air and Stack Monitor. Digital. Installed. Continuous. Designed for near real time ultra-low level Tritium detection in Nuclear Power Plants using sample enrichment and proportional counting. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Triathalon Series
    Tritium Ultra Low Air

    Triathalon Tritium Ultra Low Range Monitor. Digital. Installed or Rack Mounted. Continuous. Sensitive, rugged stack or effluent. Designed for Nuclear Power Plants. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface. Commercial version available for research labs, room air, glove boxes and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TOTAL-6
    NPP Stack/Effluent

    Stack Monitor. Digital. Installed. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium and C-14 with focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Data archive/retrieval. Local and remote alarming and monitoring. A Commercial version is available for research labs, room air, glove boxes and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VADO-ZONE

    VAP-X-Radon
    VADO-Zone/Soil System

    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates: Pin-point leak source / location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Radon vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Tritium
    VADO-Zone/Soil System

    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates: Pin-point leak source / location. Map underground plume. Locate edge of plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .