Searching for "NPP-H2O"

Number of results 15

  • NPP-H2O

    Highly Sensitive for Nuclear Power Plants

    Real-Time Continuous Water Monitor
    Model: NPP-H2O  /  NPP-H2O-G  /  NPP-GAMMA  /  NPP-GAMMA-G  /  NPP-BETA  /  NPP-ALPHA

    NPP-H2O, NEXGEN-SEA, NEXGEN-SSS, NEXGAMMA-2

    Features

    • World’s Only PAG-level αβγ Water Monitor
    • Measures at or Below EPA/dhs PAG-Levels (EPA’s Protective Action Guideline Levels)
    • Real-Time, In-Line, Continuous
    • Detects Alphas, Betas, and Gammas
    • Gamma-MCA Isotope Identifier
    • Detector Type: Nai (Tl) Or HPGe
    • Tritium and C-14 Optional Detection
    • No Reagent Tanks to Fill
    • No Waste Stream
    • Easy Calibration
    • Full SCADA Compatibility

    Problem
    Most nuclear power stations have high-range water monitors for monitoring coolant leaks, but low-range water monitors for real-time, online users have not been available until now. Very few nuclear power plants have real-time radiation monitors in place to protect the water and the public, spot problems early, and ensure compliance with current regulations.

    Solution
    For the first time in a Continuous Real-Time Water Monitor, the Model NPP-H2O solves this problem by continuously monitoring the water using Alpha, Beta, and Gamma detectors and Gamma-MCA identifiers. Determines and identifies individual radionuclides.

    Page One of Data Sheet

    Page Two of Data Sheet

    Complete Data Sheet

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Water & Liquid Effluent Monitors

    Nuclear Power Monitors

    MODEL

    DESCRIPTION

    High-Range Submersible Ion Chamber Digital. Portable. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven Model CP-MU coupled to a submersible ion chamber, 60 feet of special low noise cable with a waterproof coupling to the detector. Local readout. Optional: Computer interface.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    High-Range Submersible Monitors. Digital. Portable. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET driven Model CP-MU coupled to specific ion chamber detectors for use monitoring reactor core and fuel pool and their components. Very High Range. Local readout. Optional: Computer interface. Five Linear Ranges:

    • CP-MU-D1: GAMMA High Range
    • CP-MU-D100: GAMMA Mid Range
    • CP-MU-D1000: GAMMA Low Range
    • CP-MU-7-D1: GAMMA Very High Range
    • CP-MU-GN: Gamma and Neutron Proportional Detector

    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Under Water High-Capacity Ion Chamber Probes. Used with the CP-MU series of electronics.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FPT Series
    Fuel Pool Tool

    Fuel Pool Tool. Digital. Installed. Detects Tritium in NPP pool water, and pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only FPT-H3. (1) Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    LIQ-X(H3)
    Tritium in Water

    Tritium in Water Monitor. Digital. Benchtop. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra-Sensitive Tritium in Water Monitor. Heavy water leak detector. Installed. Digital. Fully automated, real-time, and continuous. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water. Integrated computer with custom software and large LCD display. Monitors water below the EPA drinking water standard of 20,000 pCi/l. Computer interface with ethernet and USB.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MSTR-H2O
    Thorium Reactor Water

    Molten Salt Thorium Reactor Water Monitor. Real-time Continuous. Digital. Installed. Detects Thorium, Tritium, Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking/Waste Water Monitor. Digital. In-Line or transportable (Rack Mounted or Wheeled Base). Continuous Real-Time. Detects Gamma. Monitor ground, surface water, industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TI) or HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Use NEXGAMMA-2-SEA in Salt Water/Harsh Environments. Five models from which to choose. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    • Optional: Detectors: Alpha, Beta, Tritium, Radon
    • Optional: Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NEXGEN-SEA
    Sea Water Monitor

    Sea Water Monitor Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    Optional: Ozone System.
    Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Water Monitor. Digital. Bench Top or Rack mounted. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Meets EPA drinking water levels.

    • Monitor Leaks in Candu Type Reactors
    • Monitor Tritium Contamination in Ground Water.
    • Monitor Laboratory or Plant Liquid Waste Stream.

    Strategy for Measurement of Tritium in Water / Oil Mixture

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NPP-H2O
    Nuclear Power Water

    Nuclear Power Water Monitor. Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PEMO-7
    Strap-On Pipe Monitor

    Strap-On Water Pipe Monitor Series. Digital. Installed. Continuous Real-Time. Gamma detection. Flow rate is not a factor. Constant check and alarm. Single channel (SCA) or multichannel analyzer (MCA) models. Detection for PEMO-7 and PEMO-7-MCA is with a NaI (Tl) scintillation crystal detector. Detection for PEMO-7-G is with an HPGe solid-state detector. Electronics is the FM-9W Read Out for use with multiple detectors. Local and remote alarm, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PEMO-7LE
    Strap-On Pipe Monitor

    Strap-On Water Pipe Monitor. Digital. Portable. Gamma detection of waterborne radioactivity with NaI (Tl) crystal scintillation detector. Detection of contamination flowing thru one or more pipes. Battery operated. A constant check with real-time alarm. Measurement is independent of the water flow rate. Quick set-up with no penetration, and no downtime. Electronics: Model TBM-3D with Optional: USB. Optional: computer interface for Portable system: Data archive and retrieval, integration into facility computer, and linking to multiple detectors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Low range liquid scintillation system accurately quantitatively measures Carbon-14, Tritium and most other radioactive materials. Measures low levels of Tritium even below 20,000 pCi/l, Clean Drinking Water Levels.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SSS-22P Series
    Liquid Scintillation

    Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Optional: 6 sample adapters. Six models:

    • SSS-12P 1 sample
    • SSS-22P 3 samples
    • SSS-22-MCA 3 samples with a Multichannel Analyzer
    • SSS-22PAL All-in-one suitcase version: 3 sample systems and electronics
    • SSS-22PAL-ID comes with MCA,
    • SSS-22-LR (Low Range Tritium).

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TASC
    Tritium/C-14 Sampling

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit Tritium sampler and concentrator from stacks, hoods, room air, the outside environment or other areas. System includes: Specific chemical reagents for Tritium or C-14, sample bottles, pump, mass flow controller and regulated oxidizer. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TRIMARAN H2O
    Ultra Low Tritium in Water

    Ultra Low-Level Tritium Water Monitor. Digital. Installed. Continuous Real-Time. Designed for near real-time ultra-low-level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Trimaran-H2O-ES has enhanced sensitivity in a shorter time period. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Tritium

    MODEL

    DESCRIPTION

    TRITIUM, AIR

    CAM-33 Series
    Air/Stack Monitors

    Multi-Channel Air Monitor. Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Optional: Alpha, Tritium, and Carbon-14 detection are available. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. A Commercial version is available for research labs, room air, glove boxes, and other applicable uses. Click here for screenshots

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FPT (H3) Series
    Fuel Pool Tool

    Fuel Pool Tool. Digital. Installed. Detects Tritium in NPP pool water, pool room air condensation. Monitors pool water temperature FPT-H3. Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Air and Stack Monitor. Digital. Installed. Continuous Real-Time. Ultra-sensitivity to low-level Tritium (at or Below Public Release Levels). Dose-rate and Dose. Can be located remotely. Archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 200SB is a Tritium survey monitor. Portable. Digital. No zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO-discriminating version. Local display.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 347. Digital. Highly sensitive tritium air monitor that includes four 21 ionization chambers arranged in a cruciform pattern to provide superior gamma compensation from all directions. The additional ionization chamber volume also provides enhanced stability and sensitivity. The pump, filter, and flowmeter are mounted on a separate panel and include a HEPA filter to ensure the sample is free of particulates. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Model 357 Tritium in air monitor. Digital. Portable. General-Purpose. Dual 2-liter ionization chambers for gamma compensation. Includes everything needed for operation: pump, HEPA filter, flowmeter, local display, and an adjustable single alarm setpoint with audible and visual alarms. A variety of options can be added, including data output, remote display/alarm units, noble gas compensation, wire-grid chambers to reduce plate-out contamination, and more. Local display. Optional: RS232 output; remote readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium in air monitor. Digital. Portable. Gamma compensated. High sensitivity and stability Rapid response. Four 200cc ion chambers: Two ion chambers are used for measurement (400cc total) and two for gamma compensation (400cc total). NiMH rechargeable batteries. Optional: AC adapter. RS232 Data output. CE Marked.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MoRAD

     

    Mobile Radiation. Digital. Portable. Detects Beta-Gamma Radiation and Neutron. Choose up to 7 different detectors for simultaneous detection. Electronics in the vehicle. Detectors in or mounted to vehicle or robot. Optional: Targeted OMNI directional detector. Built-in GPS. For use in first responder or command center vehicles for alerting to the presence of radioactivity in the area. Local alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PTG-9
    Tritium Air Monitor

    Tritium Air Monitor. Digital. Portable. Wide range. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, a mass flow controller, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair
    Tritium and C-14

    Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real-time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local Readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriMaran-Air and Stack
    Ultra Low-Level Tritium

    Ultra Low-Level Automated Tritium Air and Stack Monitor. Digital. Installed. Continuous. Designed for near real-time ultra-low level Tritium detection in Nuclear Power Plants using sample enrichment and proportional counting. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Triathalon Series
    Tritium Ultra Low Air

    Triathalon Tritium Ultra Low Range Monitor. Digital. Installed or Rack Mounted. Continuous. Sensitive, rugged stack, or effluent. Designed for Nuclear Power Plants. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface. The commercial version available for research labs, room air, glove boxes, and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TOTAL-6
    NPP Stack/Effluent

    NPP Stack/Effluent Monitor. Digital. Installed. Continuous. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium and C-14 with focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface. A Commercial version is available for research labs, room air, glove boxes and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    The TRI-DECON is a high efficiency Tritium decontamination system. Convenient with ease of use this miniature Tritium Gas Removal Facility provides a rugged system for harsh environments, is in-line operated provides inlet and outlet hoses for decontamination of fume hood, exhaust stack, etc interiors. Powered by Rechargeable battery with built in charger.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    STG-4S/D and STG-5ATL
    Tritium Monitor

    Tritium Monitor. Continuous Real-Time. Digital. Installed. Continuous. Public release level, sensitive, rugged stack, or effluent monitors. The STG-5ATL will measure airborne Tritium as HTO. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    H3-PLR Series
    Tritium Monitor

    Tritium Monitor. Continuous Real-Time. Digital. Installed. Continuous. Public release level, sensitive, rugged stack, or effluent monitors. H3-PLR-5 – 5 decade. H3-PLR-7 – 7 decade.  Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TASC
    Tritium/C-14 Sampling

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pump, mass flow controller, and regulated oxidizer. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    • UNITECT-AIR combines several detection goals into a single monitor.
    • The UNITECT-AIR continuously monitors Radionuclides using a particulate filter and charcoal filter.
    • Both Industrial and Warfare Chemicals, as well as Biological Threats including Bacteria, Yeast, viruses, and Mold, are monitored with detectors integrated within the UNITECT-AIR system.
    • Additional monitoring is available and will be tailored to specific needs upon request
    • Measurements are logged 24 hr/day - 7 days/week, with alarm capability and a universal read-out adaptable to mainframe infrastructure computers.
    • Local and remote readout and alarm.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VAP-X-Tritium
    Vapor Extraction/Soil
    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates Pin-point leak source/location. Map underground plume. Locate edge of the plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    WATER

    Fuel Pool Tool. Continuous Real-Time monitor. NRC rules require close real-time monitoring of fuel pool status and parameters. For the first time in a Continuous Real-Time monitor TA's FPT-H3 solves this problem by continuously monitoring water and air using Tritium detectors. FPT-H3-ABG incorporates Alpha, Beta, and Gamma detectors for water.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium in Water Monitor. Digital. Benchtop. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra-Sensitive Tritium in Water Monitor. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water fully automated, real-time, continuous. Integrated computer with custom software and large LCD display. Monitors water below EPA drinking water standard of 20,000 pCi/l.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Molten Salt Thorium Reactor Water Monitor. Real-time Continuous. Digital. Installed. Detects Thorium, Tritium, Alpha, Beta and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Nuclear Power Water Monitor. Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Water Monitor. Continuous Real-Time. Digital. Portable or Installed. Detects Alpha, Beta, Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface. (3) Models:

    • (1) Portable with User’s electronics
    • (1) Installed with embedded processor
    • (1) Portable with embedded processor

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking/Waste Water Monitor. Digital. In-Line or transportable (Rack Mounted or Wheeled Base). Continuous Real-Time. Detects Gamma. Monitor ground, surface water, industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TI) OR HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Use NEXGAMMA-2-SEA in Salt Water / Harsh Environments. Five models from which to choose. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    • Optional: Detectors: Alpha, Beta, Tritium, Radon
    • Optional: Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    • Optional: Ozone System.
    • Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking-Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the RAWA-GP option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. FAQ

    • Optional: Ozone System.
    • Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water).

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Water Monitor. Digital. Bench Top or Rack mounted. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Meets EPA drinking water levels.

    • Monitor Leaks in Candu Type Reactors
    • Monitor Tritium Contamination in Ground Water.
    • Monitor Laboratory or Plant Liquid Waste Stream.

    Strategy for Measurement of Tritium in Water / Oil Mixture

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Digital. Bench Top. Military level water test for potable water. Accurately quantitatively measures Carbon-14, Tritium, and most other radioactive materials. measures the low level of Tritium even below 20,000 pCi/l, Clean Drinking Water Levels. meets New Requirements for Military Drinking Water TB MED 577/ NAVMED P-5010/AFMAN 48-138_IP May 2010.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Detects all Alpha/Beta Emitters and Low Energy Gamma Emitters–Including-Tritium, Carbon-14, and Sulphur-35 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Multichannel Analyzer SSS-22-MCA, suitcase version of SSS-22P SSS-22PAL, lab version of SSS-22P SSS-22LAB.  Local readout and alarm. Computer interface. Optional: 6 sample adapter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Down Hole Tritium in Water Detector. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels. Protective ActionGuideline (PAG) / Military Drinking Water limits.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Radon and Tritium Deionizer and Filter. Is a two-stage deionizer producing water equivalent to -distilled water. SSS-33M8-D are the deionizer cartridges. SSS-33M8-F is the Filter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra Low-Level Automated Tritium Water Monitor. Continuous. Designed for near real-time ultra-low level Tritium Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Integrated Chemical, Biological and Radiation Water Robust, Continuous Real-Time. Monitoring System. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Continuous real-time monitoring. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration

    SURVEY, SURFACE, WIPE TEST

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CURIE-H3-PLO
    Wipe Test

    Low Range Tritium Wipe Test Counter. Portable. Measure down to 500DPM. 3" Sample drawer. The unique ion chamber sample counter provides low range Tritium measurement and eliminates the need for a pressurized gas supply or LSA cocktail. USB Output. User-specified engineering units.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    High Range Tritium Wipe Test Counter. An Ion Chamber Sample Counter with FM-9 Smart Electronics. Designed for low energy, HIGH activity counting. Ideal for fusion research or in Tritium production and use. Choice of 5 decades or Optional 8 decades. No LSC or pressurized gas requirement equals no Waste. Computer Interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FF-27
    Tritium Surface

    Tritium and C-14 Surface Contamination Meter. Digital. Portable Gas flow proportional detector. Use for flat surfaces. 100cm2 sensitive area. Local readout. Optional: probe for hands, clothing, and equipment.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium survey monitor. Portable. Digital. No zero drift over a temperature range of 0° C to +50° C. A 4 1/2 digit LCD display for readings from 0 to 19,999 MPCA. A large pump and fast electronics combine to give this instrument a fast overall response. This instrument is useful where measurement sensitivities of the order of 10 μCi/m3 (1 MPCA) is sufficient, and where a wide range, a fast response is needed. Model 200 SB HTO is an HTO discriminating version. Local display.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    STB-TF-6
    Tritium Wipe Test

    Tritium Wipe Test Counter. Digital. Portable. Detects Tritium, Carbon-14, Sulfur-35, etc. Gas flow proportional detector. Electronics PRS-7. Three single-channel analyzer windows. AC or rechargeable battery power. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Portable Tritium monitor. Based on our popular Model 400 platform and is a small, high sensitivity, handheld, battery (rechargeable) operated, fully Gamma-compensated survey meter with RS232 serial data output and user recalibration features.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VADO-ZONE

    VAP-X-Tritium
    VADO-Zone/Soil System

    VADO-Zone/Soil Air System. Digital. Portable. Vapor extraction from soil facilitates Pin-point leak source/location. Map underground plume. Locate the edge of the plume. Locate problem areas. System detection chart details extraction of Tritium vapor in soil process. Local and remote alarming readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Water

    Tritium: Water Monitors

    MODEL

    DESCRIPTION

    FPT-H3 Series
    Fuel Pool Tool

    Fuel Pool Tool. Digital. Installed. Detects Tritium in NPP pool water, pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only (FPT-H3). (1) Tritium plus Alpha-Beta-Gamma Detectors (FPT-H3-ABG). Data archive/retrieval. Local and remote alarm, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium in Water Monitor. Digital. Benchtop. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra-Sensitive Tritium in Water Monitor. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water  Fully automated, real-time, continuous. Integrated computer with custom software and large LCD display. Monitors water below EPA drinking water standard of 20,000 pCi/l.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Molten Salt Thorium Reactor Water MonitorReal-time Continuous. Digital. Installed. Detects Thorium, Tritium, Alpha, Beta and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Water Monitor Continuous Real-Time. Digital. Portable or Installed. Continuous. Detects Alpha, Beta, and Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Nuclear Power Water Monitor. Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    Optional: Ozone System.
    Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital, Bench Top or Rack mounted. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Meets EPA drinking water levels.

    • Monitor Leaks in Candu Type Reactors
    • Monitor Tritium Contamination in Ground Water.
    • Monitor Laboratory or Plant Liquid Waste Stream.

    Strategy for Measurement of Tritium in Water / Oil Mixture.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking/Waste Water Monitor. Continuous Real-Time. In-Line or transportable (Rack Mounted or Wheeled Base). Detects Gamma. Monitor ground, surface water, industrial liquid-waste-stream. MCA isotope Identifier – Detector Type:   NAI (TL) OR HPGE. Optional: NEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector.

    Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    Optional: Detectors: Alpha, Beta, Tritium, Radon. Optional: Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking-Water Monitor Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
    Optional: Ozone System. Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water). FAQ

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. SSS-22-LAB with stainless steel case, lab version of SSS-22P. Local readout and alarm. Computer interface. Optional: 6 sample adapters.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Optional: 6 sample adapters. Six models:

    • 1 sample SSS-12P
    • 3 samples of SSS-22P,
    • 3 samples with a Multichannel Analyzer SSS-22-MCA,
    • All-in-one suitcase version: 3 sample systems and electronics SSS-22PAL
    • SSS-22PAL-ID comes with MCA,
    • SSS-22-LR (Low Range Tritium).

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Digital. Bench Top. The suitcase version of SSS-22P (SSS-22PAL or SSS-22PAL-ID with MCA), Quantitatively measures Carbon-14 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample SSS-12P, 3 samples SSS-22P, 3 samples with a Multichannel Analyzer SSS-22-MCA, lab version of SSS-22P SSS-22LAB, SSS-22-LR (Low Range Tritium). Local readout and alarm. Computer interface. Optional 6 sample adapter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    MIL-Water Safety Test Liquid Scintillation Counting System. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Portable electronics (SSS-22LR). Installed electronics (SSS-22LRX). Local readout and alarm. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Down Hole Tritium in Water Monitor. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline. Five models:

    • SSS-33-DHC and SSS-33-DHC-4 each will deploy to 160 feet.
    • SSS-33-DHC utilizes a two-inch diameter well hole.
    • SSS-33-DHC- 4 utilizes a four-inch diameter well hole.
    • SSS-33-DH-XT utilizes a two-inch diameter well hole and will deploy 5,000 feet.
    • SSS-33-DHC-WH and SSS-33-DHC-4-WH utilize the WELL-HEAD (WH) SERIES procedure.

    The WELL-HEAD (WH) SERIES procedure has the same function as the other models, with significantly higher sensitivity and reduced maintenance by the simple expedient of placing only the pump down the hole and bringing the detection cell, filtration, and amplifiers up to the surface where they can sit alongside the readout and data transmission package which was already on the surface at the WELL-HEAD. There are thousands of boreholes in the United States which could be or should be monitored for Tritium.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Radon and Tritium Deionizer and Filter. Is a two-stage deionizer producing water equivalent to -distilled water. SSS-33M8-D are the deionizer cartridges. SSS-33M8-F is the Filter.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra Low-Level Tritium Water Continuous Real-Time Monitor. Digital. Installed. Designed for near real-time ultra-low-level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Trimaran-H2O-ES has enhanced sensitivity in a shorter time period. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Tritium Instruments

    Model

    Description

    Single Purpose – Tritium In Water with Optional C14

    Digital. Benchtop.

    Tritium in Water Monitor. Real-time continuous water monitor. Monitors leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory, or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Molten Salt Thorium Reactor Water Monitor. Real-time Continuous. Detects Thorium, Tritium, Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Ultra-Sensitive Tritium in Water Monitor. Heavy water leak detector. Fully automated, real-time, and continuous. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water. Integrated computer with custom software and large LCD display. Monitors water below the EPA drinking water standard of 20,000 pCi/l. Computer interface with ethernet and USB.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TRIMARAN H2O
    Ultra Low-Level Tritium in Water

    Digital. Installed.

    Ultra Low-Level Tritium Water. Continuous Real-Time Monitor. Designed for near real-time ultra-low-level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Trimaran-H2O-ES has enhanced sensitivity in a shorter time period. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multi-Detector; Tritium in Water

    Digital. Installed.

    Fuel Pool Tool. Detects Tritium in NPP pool water, and pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only FPT-H3. (1) Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout, and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Ozone System. Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Drinking Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the RAWA-GP option. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Ozone System. Optional: Detectors: Tritium, Radon, or RAWA-GP (Raw Water). FAQ 

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Nuclear Power Water Monitor. Continuous Real-Time. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, and Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Benchtop.

    Liquid Scintillation Counting System. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Six models:

    • 1 sample SSS-12P
    • 3 samples of SSS-22P
    • 3 samples with a Multichannel Analyzer SSS-22-MCA
    • All-in-one suitcase version: 3 sample systems and electronics - SSS-22PAL
    • SSS-22PAL-ID comes with MCA
    • SSS-22-LR (Low Range Tritium)

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Nuclear Power Instruments

    Water Security - Nuclear Power

    MODEL

    DESCRIPTION

    Digital. Portable.

    High-Range Submersible Monitors. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven Model CP-MU coupled to specific ion chamber detectors for use monitoring reactor core and fuel pool and their components. Very High Range. Local readout. Optional: Computer interface. Five Linear Ranges:

    • CP-MU-D1: GAMMA High Range
    • CP-MU-D100: GAMMA Mid Range
    • CP-MU-D1000: GAMMA Low Range
    • CP-MU-7-D1: GAMMA Very High Range
    • CP-MU-GN: Gamma and Neutron Proportional Detector.

    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Portable.

    High-Range Submersible Ion Chamber. 5 decades. Reads 0.1 to 10,0000 R/hr. The electronic package is a lightweight, waterproof, 6 AA cell operated, solid-state, and MOSFET is driven Model CP-MU coupled to a submersible ion chamber, 60 feet of special low noise cable with a waterproof coupling to the detector. Local readout. Optional: Computer interface.
    Click For Portable Ion Chamber Comparison Chart

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FPT-H3 Series
    Fuel Pool Tool

    Digital. Installed.

    Fuel Pool Tool. Detects Tritium in NPP pool water, and pool room air condensation. Monitors pool water temperature. (2) models: (1) Tritium only FPT-H3. (1) Tritium plus Alpha-Beta-Gamma Detectors FPT-H3-ABG. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Benchtop.

    Tritium in Water Monitor. Real-Time- Automatic, Continuous Water Monitoring. Monitor leaks in Candu-type reactors; Thorium and Fusion Research Reactors. Monitor for Tritium radiation in groundwater, laboratory, or plant liquid waste stream. Low activity LIQ-X-LO. Mid activity LIQ-X-HI. High activity LIQ-X-HI. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A and N.42.18. For low-level Tritium see Nex-Tritium H2O.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Ultra-Sensitive Tritium in Water Monitor. Heavy water leak detector. Fully automated, real-time, and continuous. Dual proportional counters, hydrogen separator to separate hydrogen (Tritium) from water. Integrated computer with custom software and large LCD display. Monitors water below the EPA drinking water standard of 20,000 pCi/l. Computer interface with ethernet and USB.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Molten Salt Thorium Reactor Water Monitor. Real-time Continuous. Detects Thorium, Tritium, Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (4) Detectors: Alpha, including Thorium 232 and Uranium 238; Beta scintillation; Gamma with MCA analyzer; Tritium scintillation detector. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed or Transportable.

    Drinking/Waste Water Monitor. In-Line or transportable (Rack Mounted or Wheeled Base). Continuous Real-Time. Detects Gamma. Monitor ground, surface water, and industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TI) or HPGE. OptionalNEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Use NEXGAMMA-2-SEA in Salt Water / Harsh Environments. Five models from which to choose. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    • Optional: Detectors: Alpha, Beta, Tritium, Radon
    • Optional Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Sea Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma in seawater. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    • Optional: Ozone System.
    • Optional: Tritium detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital, Benchtop, or installed.

    Water monitor for Alpha isotopes: Most Alphas including U-238, Po-210, and Radon. Continuous Real-Time water monitor. Monitor for contamination of in-ground or surface water. Monitor liquid waste stream from hospitals, laboratories or plants, mining/oil/gas extraction, and Nuclear Power plants. Data archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Portable or Benchtop.

    Water monitor for Beta isotopes: Detects I-131, Sr-90/Y-90, Sr-89, Cs-137, Cs-134, etc. Continuous, Real-Time Monitor drinking water against any and all Beta Emitter Contaminants except H-3, C-14, and S-35 Monitor for contamination in-ground or surface water Monitor liquid waste stream from laboratory or plant. Data archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Bench Top or Rack Mounted.

    Tritium Water Monitor. Continuous real-time display analyzes Low-Level Tritium output through twin pairs of matched photomultiplier tubes. Not influenced by other nuclides. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Meets EPA drinking water levels. Strategy for Measurement of Tritium in Water / Oil Mixture.

    • Monitor Leaks in Candu Type Reactors.
    • Monitor Tritium Contamination in Ground Water.
    • Monitor Laboratory or Plant Liquid Waste Stream.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Nuclear Power Water Monitor. Continuous Real-Time. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, and Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Tritium, C-14, Radon detection. Strategy for Measurement of Tritium in Water / Oil Mixture.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Strap-On Water Pipe Monitor Series. Continuous Real-Time. Gamma detection. Flow rate is not a factor. Constant check and alarm. Single-channel (SCA) or multichannel analyzer (MCA) models. Detection for PEMO-7 and PEMO-7-MCA is with a NaI (Tl) scintillation crystal detector. Detection for PEMO-7-G is with an HPGe solid-state detector.  Electronics is the FM-9W Read Out for use with multiple detectors. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Portable.

    Strap-On Water Pipe Monitor. Gamma detection of waterborne radioactivity with NaI (Tl) crystal scintillation detector. Detection of contamination flowing thru one or more pipes. Battery operated. A constant check with real-time alarm. Measurement is independent of the water flow rate. Quick set-up with no penetration, and no downtime. Electronics: Model TBM-3D with Optional: USB. Optional: computer interface for Portable system: Data archive and retrieval, integration into facility computer, and linking to multiple detectors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TRIMARAN H2O
    Ultra Low-Level Tritium in Water

    Digital. Installed.

    Ultra Low-Level Tritium Water Monitor. Continuous Real-Time. Designed for near real-time ultra-low-level Tritium. Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Trimaran-H2O-ES has enhanced sensitivity in a shorter time period. Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Radium, Radon, Uranium

    Water Security

    Model

    Description

    Digital. Installed. Transportable.

    Drinking/Waste Water Monitor. Digital. In-Line or transportable (Rack Mounted or Wheeled Base). Continuous Real-Time. Detects Gamma. Monitor ground, surface water, and industrial liquid-waste-stream. MCA isotope Identifier – Detector Type: NAI (TI) OR HPGE. OptionalNEXGAMMA-2 Br has a LaBr (Lanthanum Bromide Scintillation) detector. Use NEXGAMMA-2-SEA in Salt Water / Harsh Environments. Five models from which to choose. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    • Optional: Detectors: Alpha, Beta, Tritium, Radon.
    • Optional: Submersible Gamma probe

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Drinking Water Monitor. Continuous Real-Time. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional: Ozone System. Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water). FAQ 

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Nuclear Power Water Monitor Continuous Real-Time. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, and Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. UV Lamp: Used on the inlet as an algaecide. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Optional Tritium, C-14, and Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Radium in Water Removal System. Digital. Installed. Ion Exchange system for small water systems. The system Includes One TADR-M-150-2 progressive flow water softener with meter-controlled regeneration. (2) 5 cubic foot steel resin tank. (2) MVP control. (2) Meter assembly and cable. (1) Brine (salt storage tank) 24 x 50. (1) Initial salt fill (400 lbs/ten 40 lb bags). Flow Rate: Typical 500 GPM, Total Flow:7,500 gallons per day. Installation is available in the USA.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Radium-TA Series
    Radium In Water

    Digital. Portable or Installed

    Radium in Water System. Digital. Detects Alpha. (2) modelsRADIUM-TA or RADIUM-MCA with Alpha Multichannel Analyzer. Multiple components: Water Pump, radium collection cell, scintillation detector, electronics. Optional: In-Line Radium Detector. Sensitivity 3 Pico curie per Liter Total Radium. (2) Electronics options:

    • RADIUM-MCA with MCA-TA (Multi-Channel Analyzer) and Semiconductor Crystal. Local readout, computer interface.
    • RADIUM-TA with PRS-7 digital scaler and ZnS(Ag) Scintillator. Local readout. Optional: computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RADON-7
    Portable Radon

    Digital. Portable.

    Radon in Water. Analog. Portable. Radon Alpha Scintillation system and combines a modified PAS-8 Alpha Scintillation Probe plus FLO-9 water-flow-thru sampler. Monitor aquifer for rising Radon levels in complying with EPA and Water Districts standards. Local readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Installed.

    Radon and Tritium Deionizer a Filter. Is a two-stage deionizer producing water equivalent to -distilled water. SSS-33M8-D are the deionizer cartridges.
    SSS-33M8-F is the Filter. Use with SSS-33M8-R (Radon) and LIQ-X (Tritium).

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Benchtop or Rack Mounted.

    Radon Water Monitor. Continuous Real-Time. Detects and alerts to rise in radon levels in drinking water. Sensitive to 200 pCurie/liter. Not influenced by other nuclides. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Benchtop or Rack Mounted.

    Integrated Chemical, Biological, and Radiation Water Robust, Monitoring System. Continuous real-time monitoring. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Digital. Portable or Installed

    Uranium-TA Series Water Monitor. Two types of electronics. A single-channel analyzer is in both the portable and installed models of the Uranium-TA. The Installed version has the option to use the multi-channel analyzer, Uranium-MCA. Perfect for in-the-field use at fracking sites, uranium mines, and Super Fund clean-up sites. The PRS-7 electronics works with both versions of the Uranium-TA, portable and installed. Powered by AC or rechargeable batteries. Optional: Computer interface and Alarm Relay. The model Uranium-MCA is a benchtop electronics package with a customer-tailored radionuclide library. Data archive and retrieval. Powered by AC and internal batter backup. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Tritium in Water Monitors

    MODEL

    DESCRIPTION - SINGLE PURPOSE ~ TRITIUM IN WATER WITH OPTIONAL C-14

    Tritium in Water Monitor Real-Time Continuous Series.

    Digital. Bench Top. Low activity (LIQ-X-LO). Mid activity (LIQ-X-HI). High activity (LIQ-X-HI). Data archive/retrieval. Local and remote alarm, readout, and monitoring. Computer interface. Complies with relevant sections of ANSI 42.17A & N.42.18. For low-level Tritium see Nex-Tritium H2O.

    Optional: C-14

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Low-Level Tritium Water Monitor. Digital. Bench Top or Rack Mounted. Continuous. Twin pairs of matched photomultiplier tubes. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Monitor leaks in CANDU-type reactors. Monitor Tritium contamination in groundwater, laboratory or plant liquid waste stream. Meets EPA drinking water levels.

    Optional: C-14

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Low-level detection of Tritium. Continuous Real-time low-level detection of Tritium in water in nuclear power plants. Low MDA, reliability, ruggedness (suitable for HWR, PWR, BWR), and simplicity of operation.  Matched gas proportional detectors. 6 inputs for sampling 6 individual lines. Detect heavy water leaks in nuclear power plants that utilize CANDU reactors. Other applications: monitoring changes in Tritium content of groundwater, drinking water, and wastewater.  Built-in computer, local and remote readout. Computer interface, easy integration into facility mainframe.

    Optional: C-14

    . . . . . . . . . . . . . . . . . . . . .

    MULTI-DETECTOR TRITIUM IN WATER

    Fuel Pool Tool

    NRC rules require close real-time monitoring of fuel pool status and parameters. For the first time in a Continuous Real-Time monitor Ta's FPT-H3 solves this problem by continuously monitoring water and air using Tritium detectors and optional Alpha, Beta, and Gamma detectors.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Ultra Low-Level Automated Tritium Water Monitor.

    Digital. Installed. Continuous. Designed for near real-time ultra-low level Tritium Designed for Nuclear Power Plants. Monitor changes in Tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    OptionalC-14

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Sea Water Monitor, Continuous Real-Time

    . Digital. Installed. Continuous. Multidetector system for Alpha, Beta, and Gamma in sea water. Multichannel Analyzer (MCA). Monitor liquid effluent around sea water-cooled nuclear power plants and desalination plants. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    Optional Ozone System.
    Optional Tritium detection.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking-Water Monitor, Continuous Real-Time.

    Digital. Installed. Continuous. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the (RAWA-GP) option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.

    Optional Ozone System.
    Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water).

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Nuclear Power Water Monitor, Continuous Real-Time.

    Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. Multichannel Analyzer (MCA).

    (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
    Optional Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System

    Digital. Bench Top. Detects all Alpha/Beta Emitters and Low Energy Gamma Emitters–IncludingØTritium, Carbon-14, & Sulphur-35 and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. 1 sample (SSS-12P), 3 samples (SSS-22P), 3 samples with a Multichannel Analyzer (SSS-22-MCA), suitcase version of SSS-22P (SSS-22PAL), lab version of SSS-22P (SSS-22LAB).  Local readout and alarm. Computer interface.

    Optional 6 sample adapter.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    UNITECT-H2O

     

    Integrated Chemical, Biological & Radiation Water Robust, Continuous Real-Time. Monitoring System.

    Digital. Installed. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . .

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Radon and Radium

    Radon, Radium, Thoron

    MODEL

    DESCRIPTION

    RADON IN AIR

    ABG-NET Series
    Networked or Stand
    Alone Air Monitor

    Networked or Standalone Air Monitor. Digital. Portable or Installed. Detects Alpha, Beta Particulates, Ambient Gamma. 1 or 2 channel options. Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    • ABG-NET: One channel
    • ABG-R-NET: Second channel for Radon Moving filter head.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Thoron and Radon Gas Air Monitors. Alpha, Beta Particulate. FM-9-MA2 Series: Digital, Portable, Installed. Real-Time operation. Local or Remote Sampling and Read Out. Data archive/retrieval. Computer interface.

    • FM-9-MA2: Alpha Only
    • FM-9-MAB2: Alpha and Beta
    • FM-9-MAB2-M: Mobile. Moving filter head for FM-9-MAB2-M only.
    • FM-9-MA2-T: Gas Ion Chamber is added to the Alpha and Beta detector system.
    • FM-9-MA2-R Radon: Gas Ion Chamber is added to the Alpha and Beta detector system.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multiuse Radiation and Chemical Air Monitor. Digital. Bench Top. Choice of Radiation and Chemical sensors. Continuous. Alpha, Beta, Gamma, or combination is available. 1 each for a solid-state detector for Alpha and Beta particulates. Choose chemical sensors at the time of order. Local and remote alarm, readout, and monitoring. Flow rate 120 lpm. Real-time mass flow meter. Local Readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FR-5-FS

     

    The Rapid Radon Monitor. A System for Quick Measurement. A Collection Unit with a Quiet Pump and Charcoal Filter Holder with a Scintillation Counter/Scaler. Portable AC. 1 Picocurie Per Liter In 3 Minute Sampling. Increased Sensitivity with Longer Sampling. Replacement Cartridges Widely Available. PRS-7 Electronics. Battery or AC. Computer Interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Iodine Monitor Total Airborne Activity. Digital. Portable. Detects I-131, I-125, and I-129. Flow rate 227 lpm. Built-in timer, user-settable. Integrated exposure. The filter is under constant surveillance via a GM 2" pancake detector FR-PIB or scintillation FR-PII detector.

    FR-PII-Pb uses ½" lead shield. Use as industrial workplace and hospital breathing air measurement system, and to monitor fume hoods and stack effluent down to EPA levels. Line operated. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Radon Air Monitor

    Radon Air Monitor. Digital. Portable or Bench Top. Highly sensitive and rugged. Dual balanced ion chambers. measure airborne radon as free Radon gas (with or without Radon Daughters user’s option) as low as 1pCi/l. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RANDFAN-SX
    Radon Detect / Switch

    Radon Detection and Mitigation Switch. Digital. Installed. Integrate into building HVAC system or stand alone. Radon sensor and activates or controls Radon mitigation devices. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RnCAM
    Radon in Air

    Portable Radon Monitor. Digital. Portable. Detects Radon-220 and Radon-222 at 10 Minutes. Longer the count times (30 Minutes), the greater sensitivity. Real-time display. Local readout. Data output via proprietary software to user's laptop. The internal data log establishes daily variation in Radon concentrations. Perfect for inspectors.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Rn-EX-DET
    Radon Expel Water and Gas System

    Dual radon detectors and radon expel / water and gas system/monitor. Digital. Installed and portable. The system has two detectors. NexAlpha-R for Radon in Water (Installed) and the RnCAM for Radon in Air (Installed or portable.) FM-9W electronics include one display from the two detectors with a computer interface. Water moves through the NexAlpha-Rwhich measures Total Radon. The RnCAM measures Radon in air.

    The system removes and cleans Radon from the water via a separator chamber. Radon gas is bubbled out of the water and enters the RnCAM air monitor for measurement. The cleaned water is directed from the separator chamber to the outlet drain. The RnCAM can be detached from the system and used as a portable Radon air monitor.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TBM-IC-RN
    Fast Radon Detector

    Portable Fast Radon Detector. Digital. Portable. Detects 10 picoCi/l in 5 seconds and detects public release level in less than 10 minutes. Small, lightweight. Drift-free electrometer technology. Measures ambient radon and no air pump is required. Local readout.
    Click For Portable Ion Chamber Comparison Chart.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    VADO-Zone/Soil

    Radon Vapor Extraction Tool in the Soil and Monitor. Digital. Portable. Measures airborne Radon in any form: water vapor, hydrogen gas, or as volatile chemicals in concentrations. Rechargeable battery with built-in charger. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RADON IN WATER

    NPP-H2O
    Nuclear Power Water

    Nuclear Power Water Monitor Continuous Real-Time. Digital. Installed. Detects Alpha, Beta, and Gamma in Nuclear Power water. (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice Scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide. Optional:Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Water monitor for Alpha isotopes: Most Alphas including U-238, Po-210, and Radon. Digital, Benchtop, or installed. Continuous Real-Time water monitor. Monitor for contamination of in-ground or surface water. Monitor liquid waste stream from hospitals, laboratories or plants, mining/oil/gas extraction, and Nuclear Power plants. Data archive and retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Water Monitor Continuous Real-Time. Digital. Portable or Installed. Detects Alpha, Beta, Gamma. Designed for facilities serving vulnerable populations. Install on water inlet pipe for automatic continuous monitoring of drinking water. Optional: Tritium and Radon detection. Data archive/retrieval. Computer interface. (3) Models:

    • (1) Portable with User’s electronics
    • (1) Installed with embedded processor
    • (1) Portable with embedded processor

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NEXGEN-SSS
    Drinking Water Monitor

    Drinking-Water Monitor, Continuous Real-Time. Digital. Installed. Continuous. Multidetector system for Alpha, Beta, and Gamma. Multichannel Analyzer (MCA). Use in drinking water utility facilities. In sewage treatment plants with the RAWA-GP option. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on the inlet as an algaecide.
    Optional: Ozone System. Optional Detectors: Tritium, Radon, or RAWA-GP (Raw Water). FAQ

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Drinking/Waste Water

    Drinking-Water and Wastewater Monitor. Digital. Rack Mounted or Wheeled Base. Continuous. Detects Gamma. Monitor ground, surface water, and industrial liquid-waste-stream. Useful in complying with discharge requirements for wastewater. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. Optional: Detectors: Alpha, Beta, Tritium, Radon. Optional: Submersible Gamma probe.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RADON-7
    Portable Radon Water

    Radon in Water. Analog. Portable. Radon Alpha Scintillation system and combines a modified PAS-8 Alpha Scintillation Probe plus FLO-9 water-flow-thru sampler. Monitor aquifer for rising Radon levels in complying with EPA and Water Districts standards.  Local readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    SSS-33M8-R
    Radon Water Monitor

    Radon Water Monitor. Digital. Bench Top or Rack Mounted. Real-Time Continuous. Monitor laboratory or plant liquid waste stream. Sensitive to 200 pCurie/liter. Not influenced by other nuclides. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    RADIUM WATER MONITOR

    Radium Series
    Radium In Water

    Radium in Water System. Digital. Portable or Installed. Detects Alpha. (2) modelsRADIUM-TA or RADIUM-MCA with Alpha Multichannel Analyzer. (2) Electronics options:

    • RADIUM-MCA – with MCA-TA (Multi-Channel Analyzer) and Semiconductor Crystal.
      Local readout, computer interface.
    • RADIUM-TA with PRS-7 digital scaler and ZnS(Ag) Scintillator. Local readout.
      Optional: computer interface.

    Multiple components: Water Pump, radium collection cell, scintillation detector, electronics. Optional: In-Line Radium Detector Sensitivity 3 Pico curie per Liter Total Radium.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Radium in Water Removal System. Digital. Installed. Ion Exchange system for small water systems. The system Includes One TADR-M-150-2 progressive flow water softener with meter-controlled regeneration. (2) 5 cubic foot steel resin tank. (2) MVP control. (2) Meter assembly and cable. (1) Brine (salt storage tank) 24 x 50. (1) Initial salt fill (400 lbs/ten 40 lb bags). Flow Rate: Typical 500 GPM, Total Flow:7,500 gallons per day. Installation is available in the USA.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    UNITECT-H2O
    Integrated Water Monitor

    Integrated Chemical, Biological, and Radiation Water Robust Monitoring System. Continuous Real-Time. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, and Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Carbon 14

    CARBON-14, Tc-99, PLUTONIUM

    MODEL

    DESCRIPTION

    BAM-STAM-3Z Series
    Portable Alpha, Beta, Gamma

    Portable Alpha, Beta, Gamma. Portable. Digital. Rugged, cart-mounted (detachable). Two detector systems. Optional: Three detector system. (BAM-STAM-3ZG). Alpha, Gamma, Plutonium. Counts wipes, filters, and planchets. Includes laptop and software. Local readout. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CAM-33 Series
    Air/Stack Monitors

    Multi-Channel Air Monitor Continuous Real-Time. Digital. Installed. Detects multiple isotopes: gross Beta-Gamma, Particulates, Noble and Iodine gases with a focus on Noble and Iodine gases. Note: TOTAL-6 focus is on Tritium and C-14. 3" lead shields. 3, 4, or 6 Channels. The CAM-33-6 is the most versatile with 6 simultaneous channels. Total Noble Gas, Noble Gas Curie MeV CAM-3XG. Local and remote alarming, readout and monitoring

    Data archive/retrieval. Computer interface. Optional: Alpha, Tritium, and Carbon-14 detection is available. Local and remote alarming, readout and monitoring. A Commercial version is available for research labs, room air, and glove boxes.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    CARB-F-9 Series
    C-14/Iodine Air/Stack

    CARBON-14/Iodine Air and Stack Monitors. Digital. Installed. Electronics; Bench Top. Constant check with real-time alarm. Integrated exposure values. (3) models. Flow rate 50 lpm standard. Electronic mass flowmeter. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FASTCAM-5
    Plutonium Air Monitor

    Quick Response Plutonium Air Monitor. Digital. Portable. Electronics; Portable or Bench Top. Sees Alphas and Betas in high or varying background situations. Two different detectors. Stand-alone or networked with other detection locations. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FF-27
    Tritium Surface

    Tritium and C-14 Surface Contamination Meter. Digital. Portable. Gas flow proportional detector. Use for flat surfaces. 100cm2 sensitive area. Local readout. Optional: probe for hands, clothing and equipment.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    FM-9ABNI
    PET/Iodine/99m

    PET, Iodine, Tc-99m DTPA Air Monitor. DigitalPortable. Electronics; Bench Top or Cart Mount. Detects Gas and Particulates. High Sensitivity, Constant Check. Integrated Exposure. Application: Hospitals / Research, Power Plants, National Labs.

    Local and remote alarming, readout and monitoring. Data archive/retrieval. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    PET, Iodine, or Tc-99m DTPA Air Monitor. Digital. Bench Top. Multi-Channel Analyzer (MCA). Continuous. Monitor air room or stack effluent. Local readout. Data archive/retrieval. Computer interface. Flow rate 70 lpm standard. Optional lpm available.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Iodine-125 Air Gas and Particulate Air Monitor. Digital. Multi-Channel Analyzer (MCA). Continuous. Local readout. Data archive/retrieval. Computer interface. Computer interface. Flow rate 70 lpm standard.

    Optional: lpm available. ID System detects peaks at very low I-125 Gamma concentrations. Can be modified to detect and measure I-131 and PET. Monitor room air or stack air effluent.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Multi-detector air monitor for Molten Salt Thorium Reactors. Digital. Installed. Real-time simultaneous measuring of Alpha, Beta (including Thorium 232) Gamma, Tritium, Carbon-14 and Noble Gases with Radon rejection. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    NPP-H2O
    Nuclear Power Water

    Nuclear Power Water Monitor Continuous Real-Time. Digital. Installed. Detects Alpha, Beta and Gamma in Nuclear Power water. Multichannel Analyzer (MCA). (6) models depending on detector type. Alpha, Beta, Gamma scintillation detectors. Gamma detector choice scintillation or Germanium (HPGe). Monitor liquid effluent from nuclear power plants. Data archive/retrieval. Local and remote alarming, readout and monitoring. Computer interface. UV Lamp: Used on inlet as algae-cide. Optional: Tritium, C-14, Radon detection.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Carbon-14 Air/Stack

    Carbon-14 Air/Stack Monitor. Digital. Electronics; Portable or Bench Top. Wide range. A sensitive, rugged, and portable instrument for detection and measurement of airborne C-14. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Tritium Wipe Test Counter. Speedy Feret. Digital. Portable. Detects Tritium, Carbon-14, Sulfur-35, etc. Gas flow proportional detector. No shielding SF-TF-6. 1-inch lead shielding SF-TF-6 Pb. Electronics (PRS-7). Three single-channel analyzer windows. AC or rechargeable battery power. Local readout. RS-232 Computer interface. Optional: USB. Alarm relay.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Liquid Scintillation Counting System. Digital. Bench Top. Quantitatively measures Carbon-14, and most other radioactive materials. Alpha/Beta separation. Diverse samples measured include liquid, food, soil, etc. Local readout and alarm. PRS-7 electronics. Computer interface. Optional: 6 sample adapters.

    Six models:

    • 1 sample SSS-12P
    • 3 samples of SSS-22P,
    • 3 samples with a Multichannel Analyzer SSS-22-MCA,
    • All-in-one suitcase version: 3 sample systems and electronics - SSS-22PAL
    • SSS-22PAL-ID comes with MCA,
    • SSS-22-LR (Low Range Tritium).

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TBM-6SP
    Dual Detector

    Dual Detector Scintillation/Pancake TBM. Analog. Portable. Detects Alpha, Beta, Gamma, Iodine, Tc99m, and X-ray. Lightweight system. Internal 2-inch pancake GM detector downward-looking window at bottom of the case with sliding shield protector. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TASC
    Tritium/C-14 Sampling

    Tritium and Carbon-14 Air Sample Collecting System. Digital. Installed. A small self-contained unit. Tritium sampler and concentrator from stacks, hoods, room air, the outside environment, or other areas. The system includes Specific chemical reagents for Tritium or C-14, sample bottles, pumps, mass flow controllers, and regulated oxidizers. Local readout of flow rate, elapsed time, and temperature. Sample bottles are sent to an outside lab for Tritium concentration analysis.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TBM-IC-LR
    Low Range Gammas and Betas

    Low Range Ion Chamber. Digital. Portable. Measures Alpha, Beta, Gamma, and X-Ray. All Gammas Including Low Energy Gammas, Betas (C-14), and X-Rays. Detects X-Ray pulse down to 0.002 μR. Measures down to the background. Measures all Gammas including low-energy Gammas and X-Rays. Sees axially below 5 KeV Gamma or X-Rays. Wide range 0.1 mR/hr to1,000R/hr. Local readout: 8 digit-rate, 8-digit integration. Free Air ion chamber. Internal volume 2 liters. ANSI N42.33 Homeland Security Type 2.
    Click For Portable Ion Chamber Comparison Chart.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TBM-6SP
    Dual Detector

    Dual Detector Scintillation/Pancake GM. Analog. Portable. Internal 2-inch pancake GM detector downward looking window at bottom of the case with sliding shield protector detects Alpha, Beta, Gamma, Iodine, Tc99m, and X-ray. External Probe: Scintillation or GM for I-125, Tc-99m, Co-57, Neutron, Positron. Local readout.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TOTAL-6
    Stack Monitors

    Stack Monitor. Digital. Installed. Highly sensitive, rugged stack or effluent monitors designed and built for Nuclear Power Plant use. Detects Gas, Particulate, Gross Beta-Gamma, Iodine, Tritium, and C-14 with a focus on Tritium and C-14. Optional: Curie MeV channel. Note: CAM-33 Series focuses on Iodine and Noble Gas. Data archive/retrieval. Local and remote alarming and monitoring. A Commercial version is available for research labs, room air, glove boxes, and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    TriCair
    Tritium/C-14

    Tritium and C-14 Detector. Digital. Portable. Fast response. Ignores Radon. Unique ability to monitor for Tritium compounds and airborne C-14 in real time while providing Gamma compensation. Flow rate 1.5-2 lpm. Local readout. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    Triathalon Series
    Tritium Ultra Low Air

    Ultra Low Range Tritium Monitor. Digital. Installed or Rack Mounted. Highly sensitive, Tritium and C-14, real-time continuous. rugged stack or effluent monitor. Designed for Nuclear Power Plants. Local and remote alarming and monitoring. Data archive/retrieval. Computer interface. The commercial version is available for research labs, room air, glove boxes, and other applicable uses.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    UNITECT-AIR
    Integrated Air Monitor

    Integrated Air Monitor: Radiation, Chemical, Biological. Digital. Installed. Robust, Continuous Real-Time. Monitoring System. Multichannel Analyzer (MCA). Several detection goals in one. Radiation, Chemical, Biological. Data archive/retrieval. Local and remote alarming, readout, and monitoring. Computer interface.

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .