English Chinese Spanish

DETECTOR TYPE DESCRIPTIONS FOR AIR & STACK MONITORS

MODEL PORTABLE AIR MONITORS
ABG-NET
HTML format
MODEL # ABG-NET is a networkable or standalone Air Monitor.
AIR-TBM
HTML format
PDF format
Portable Alpha, Beta, Gamma Air Monitor / Wipe Counter / Surface Monitor. . The AIR-TBM and uses TBM-3SR-D electronics with built-in T-1190 GM Pancake Detector. Perfect for First Responders, Hospitals, Clean Up sites, Pharmacies, etc... Battery or AC powered.
CLICK FOR GM PANCAKE TUBE RESPONSE REPORT.
AIR-TBM-SP
HTML format
PDF format
Portable Alpha, Beta, Gamma Air Monitor / Wipe Counter / Surface Monitor. Portable All-In-One Multi-Use Radiation Monitor System uses LAM-10D electronics, 2 detectors: STB-3 Alpha/Beta Sample/Wipe Counter with T-1190 GM Pancake Detector and a Gamma-Source Search Tool, the PGS-3 Scintillation probe. Ideal for First Responders. Optional RELAY for operating other equipment, door locks, fans, etc. Battery or AC powered.
CLICK FOR GM PANCAKE TUBE RESPONSE REPORT.
AP Series Pumps
HTML format
PDF format
Medium Capacity Oilless Pumps. Variable speed. Quiet 36-45 db,. 12-23 lb, 8 Models offered. Aluminum housing.
AS-100
HTML format
PDF format
Portable High Volume Air Sampler & Totalizer Monitor. Can draw air from Room or Hood. Comes with an RS-232 Computer Interface. Perfect for Hospitals, Clean up sites, Pharmacies, etc...
FM-9-ABNI
HTML format PDF format
Portable PET, Iodine, or Tc-99M DTPA Air Monitor for Gas & Particulates. Use in Hospitals, Research Labs, Power Plants, National Labs. High Sensitivity, Constant Check with Alarm and Record capability. Integrated Exposure.
FR-32, FR-42, FR-52
HTML format
PDF format
Passive RADON Monitor with TLD readout.
FR-PIB
HTML format
PDF format
Portable Air Iodine Monitor. Detects I-131 and I-125. Accurately detects in microCuries/cc. For Hospitals, Research Labs, Pharmaceutical Manufactures, and anywhere airborne Iodine concentration needed to be measured.
FR-PII
HTML format
PDF format
Portable Air Iodine Monitor. Detects I-131, I-125, and I-129. Accurately detects in microCuries/cc. For Hospitals, Research Labs, Pharmaceutical Manufactures, and anywhere airborne Iodine concentration needed to be measured.
FR-PII-Pb
HTML format
PDF format
Portable Air Iodine Monitor. Detects I-131 and I-125, I-129(Model FR-PII only). Accurately detects in microCuries/cc. For Hospitals, Research Labs, Pharmaceutical Manufactures, and anywhere airborne Iodine concentration needed to be measured. Comes with Lead Shielding.
FR-5R-FX
HTML format
PDF format
Portable Radon Air Monitor. The FR Series Air Monitor assures Safety against airborne Radon or other radioactivity contamination by means of constant check with alarm and optional record capability.
MicroBAM-3ZC
HTML format
PDF format
The portable BAM including laptop display plus software. Detects Alpha, Beta-Gamma, and Noble gases.
MFH-AB
HTML format
PDF format
Moving Filter Head for ALPHA / BETA AIR CAM.
MicroBAM-3ZL
HTML format
PDF format
The portable BAM including laptop display plus software.
MINITECT
HTML format
PDF format
The portable BAM including laptop display plus software.
PTG-9
PDF format
Portable Tritium Air Monitor. PTG-9 Tritium Monitor is a sensitive, rugged, portable instrument for detection and measurement of airborne tritium. PTG-9 is Line Operated and is Portable.
PTG-7RN
HTML format
PDF format
Portable Radon Air Monitor. PTG-7RN Radon Monitor is a sensitive, rugged, portable instrument for detection and measurement of airborne Radon. Comparision Chart
SSS-12-M3

Please Call
RADON Monitor for Lucas scintillating alpha cell. Does Not include readout. Use with FS-5T.
SSS-59

Please Call
RADON Monitor for large internal scintillating alpha cell. Does Not include readout. Use with FS-5T. (SEND FOR RADON PACKET)
MODEL STACK & TABLE TOP AIR MONITORS
FM-9-AB2
HTML format
PDF format
Alpha/Beta/Gamma Air Monitor.
FM-9-ABGN
HTML format
PDF format
Portable Iodine, Gas & Particulate Monitor. Assures safety against airborne radioactivity contamination by means of constant check with alarm and record capability.
FM-7ABNI
HTML format
PDF format
The extra sensitive Iodine monitor.
FM-7ABNI
HTML format
PDF format
The extra sensitive Iodine monitor.
FM-9-MABC
HTML format
PDF format
The FM-9-MABC is a Radiation & Chemical Air Quality Monitor. Utilizing a solid state radiation detector with two single channel analyzer windows Radon pulses are rejected. Chemical sensors for a wide variety of chemicals & particulates are available with user selection. Other sensors available are temperature, thermal, and relative humidity This is the ultimate radiation & chemical air monitor for work place air, stack effluent, hoods, glove boxes, room & environmental air.
FM-9-MA2 & FM-9-MAB2
HTML format
PDF format
Alpha and Alpha & Beta Particulate Air Monitors. Uses rugged solid state detector and two coordinated single channel analyzer windows. Real-Time operation. Local or Remote Sampling and Read Out.
FM-5XE
HTML format
PDF format
XENON Monitor. Complete system including pump and RECORDER.
FM-9-IXE
HTML format
PDF format
Iodine-125 and Xenon-125 This ratemeter system assures safety against airborne radioactivity contamination by means of constant check with alarm and record, and retrieval capability. It provides airborne concentration information for I-125 & Xe-125.
FM-9XE
HTML format
PDF format
Model FM-9XE - Xenon Gas Monitor a first choice for Xenon133 measurement in facilities globally. Sensitivity: 10-6 µCi/cc of Xe133 or 0.1 mpc. Range: 4 decades: 0.1 mpc(10-6 µCi/ml) to 1000 mpc (10-2 µCi/ml).
FM-7XE-M2
HTML format
PDF format
The FM-7XE-M2 Monitor is fast becoming the first choice for Argon41 and Noble Gas users in facilities all over the world.
FM-9-MCA-2
HTML format
PDF format
Iodine-125 Air Gas & Particulate Air Monitor with MCA (Multi-Channel Analyzer). The FM-9-MCA-2 is a continuous real-time I-125 Air Monitor. Monitor room air or stack air effluent for Iodine-125 down to low levels. Uses TA SMART-PEAKTM Isotope Identification System to detect peaks at very low I-125 Gamma concentration. Can be modified to detect and measure I-131 and PET. Mounted on a wheeled cart.
FM-9-M2
HTML format PDF format
Beta Particulate Air Monitor with Dynamic Background Subtract. Assure safety against airborne radioactivity contamination by means of constant check with audio & visual alarms and built-in data logger. It provides integrated exposure information and has digital output available.
It is a complete system but may be expanded per need with modules of the FM-9 series.
MINI-AIR-RAD

The Mini-Air Series Air Monitor assures Safety against airborne radioactivity contamination by means of constant monitoring check. Optional alarm and record capability. It provides integrated exposure information.
PERSONAL AIR SAMPLER

The Personal Air Sampler assures Safety against airborne radioactivity contamination by means of constant monitoring check. Optional alarm and record capability. It provides integrated exposure information.
PERSONAL AIR SAMPLER-BIG

The Personal Air Sampler assures Safety against airborne radioactivity contamination by means of constant monitoring check. Optional alarm and record capability. It provides integrated exposure information.
SSS-33G1
HTML format
PDF format
Flow Through Gas Monitor (Tritium).
STG-4S/D
HTML format
PDF format
Tritium Stack Monitor - Readout units and parameters established by internal processor.
STG-5ALT
HTML format
PDF format
Tritium Stack Monitor to public release levels.
STG-7L2
HTML format
PDF format
Tritium Air Stack Monitor - Self contained, easy to clean, continuous air monitor. Extremely sensative.
STG-7L4

Please Call
Detects HT and HTO separately and simultaneously 4 chambers



MODEL ACCESSORIES
DQ-7

Please Call
Data Logging Software
SC-3

Please Call
Table Stand and Collimator for Thyroid Check System.
TAC

Please Call
Flow Through Gas Calibrator (Tritium) not including tritium (SEND FOR TRITIUM CATALOG)
MRR-5

Please Call
Strip Chart Recorder Module for FM-5 Systems.
AP-4

Please Call
Air Pump complete with fittings and hoses and orifice regulator to 4 cfm.
AP-2

Please Call
Air Pump complete with fittings and hoses and orifice regulator to 1.1 cfm .
AS-2

Please Call
Regulated Air Sampler complete with pump and regulator and filter/cartridge holder and timer.

Technical Associates
7051 Eton Avenue Canoga Park, CA 91303
Phone: (818) 883-7043    
Fax: (818) 883-6103

EMAIL: TAgold@nwc.net
Español: espanol@tech-associates.com